135
4
THE INFORMATION DISPLAY
The information display
not only serves as an indicator of the (set) time and
temperature (sections C, E, and F), it also indicates any malfunctioning of the
heater. The code on the information display tells you what is the matter:
Code
Information
Action
Time
----
The heater has been automa-
tically turned off by a power
cut or bad connection.
Restore power or restore the
connection. Press the ON /
OFF key
20
20
again.
E01
An earthquake (magnitude 5
or more), strong vibrations or
a shock will ensure that the
heater automatically
turns off. (The safety system
against shocks has worked).
Make sure there are no com-
bustible materials around the
heater, or fuel leakages. Press
the ON / OFF key
20
20
again.
E02
E03
The heater has been automa-
tically turned off after a fault
or during ignition or due to
the presence of water or dust
in the fuel filter or in the
fixed tank.
Remove the water and the
dust in the fixed tank. Clean
the fuel filter (see chapter M).
Press the ON / OFF button
20
20
again.
E07
An increase in ambient
temperature has turned the
heater off. (The tempera-
ture monitoring system has
worked).
Ventilate the space. Let the
heater cool off. Press the ON /
OFF button
20
20
again.
Filter
E09
The heater has been automa-
tically turned off because the
hot air stream, the ventila-
tor or the ventilator filter
is blocked or hindered by
something. (The safety system
against overheating has
worked).
Remove obstacles from the
ventilator opening. Clean the
ventilator filter (see chapter
M) Press the ON/OFF but-
ton
20
20
again. If the problem
occurs again after taking the
above measures, contact your
dealer.
E13
The heater has been turned
off in a closed space. (The
safety system against incom-
plete combustion has wor-
ked).
Ventilate the space and press
the ON / OFF button
20
20
again.
Ensure the space is sufficien-
tly ventilated.
E17
The heater has been turned
off due to an increased CO2
concentration. (The system
for air quality monitoring has
worked).
Ventilate the space and set
the ON / OFF button
20
20
again.
Ensure the space is sufficien-
tly ventilated.
The ON indica-
tor flashes. Err
lights up
The heater has automatically
stopped because the ON / OFF
button was kept pressed in or
was blocked.
Remove obstacles around the
buttons of the display panel.
Press the ON/OFF button
20
20
again.
F00 – F30
Poor functioning. Heater
needs maintenance
Note the messages displayed
and turn the heater off. Con-
tact your dealer.
Summary of Contents for SRE7037C-2
Page 2: ......
Page 112: ...112 1 2 PVG Holding B V...
Page 114: ...114 2 5 50 2 18 07 2002 25 06 2010 C1 BS2869 2 1000 Qlima Premium Quality Fuels E E E...
Page 115: ...115 E E 1 5 8 220 240 V...
Page 116: ...116 3 3 8 3 8 IPX4 IPX4 95...
Page 117: ...117 E E E E E E A B C D E A 1 E E E 2 3 4 5 6 220 240 V AC 50 Hz 7 B 1 2 C 3 D 4...
Page 120: ...120 4 ON OFF 20 20 5 ON OFF 20 20 6 ON OFF 20 20 E01 4 3 22 22 G 1 ON OFF 20 20 8 3...
Page 121: ...121 H 45 2 3 8...
Page 123: ...123 56 ON OFF 20 20 I 3 CHILDLOCK O 3 CHILDLOCK O...
Page 125: ...125 U H05 VV F N O 1 2 3 U 4 5...
Page 127: ...127 5 6 7...
Page 223: ...223 y...
Page 225: ...225...
Page 226: ...226...