e - 4
Abnormal burning or irregular flame. Check fuel, ventilate the room,
restart the heater. Read section R
point 5. Use correct fuel (see sec-
tion “The right fuel”).
e - 5
Ignition temperature too low.
Disconnected the mains plug and
restart.
e - 6
Ignition temperature too high.
Cool down, disconnect
the mains plug and restart.
e - 7
Wrong blower speed.
Disconnect the mains plug and
restart.
e - 9
Tilt switch.
Avoid shocks. The heater must
be levelled.
e - a
Room temperature > 35°C
Ventilate the room and restart
the heater.
e - h
Electronics temperature > 60°C
Ventilate the room and restart
the heater.
KEY LOCK.
Push the button KEY LOCK 3
times to unlock the heater.
Out of fuel. + red light flashes
Refill the removable tank. Check
if the fuel filter contains water.
The heater shows the actual time
Push the – and + buttons to
adjust the time.
The heater shows the set time for
Push the – and + buttons to
timer
adjust the set time when the
heater has to start.
The heater has been operating
Switch the heater on again.
continuously for a period of 48
hours and has switched itself off
(refer to section K).
e 1 1
Too little ventilation
Ventilate better
f 0
5 sec display
Auto-restart, see chapter D
--.--
Overheating during operation or power failure during shutdown
Always contact your dealer for any malfunctioning not listed above and/or when the
error keeps occuring after taking the corrective measure as described above.
K
AUTOMATIC DEACTIVATION
This heater is equipped with a safety system that ensures that it switches off
automatically after 48 hours of continuous operation. The display will show:
.
Switch on the heater by pressing the button.
L
KEY LOCK
The key lock can be used to prevent children accidentally starting the heater. Press the
button
3 times when the heater is off. The characters KL will appear in the display.
All keys are blocked now, the heater will not respond to any pressing of the buttons.
Press the button
again 3 times to release the key lock. The status of the
is
memorized and remains after a power interrupt. Press the
button once to activate
the blue light of the background without changing other parameters