24
G
TAKE CARE
For units with a capacity of up to 6.0 kW, the maximum pipe length between the inside and the
outside part is 20 metres. For units with a capacity > 6.0 kW, the maximum pipe length between
the inside and the outside part is 30 metres.
For units with a capacity of up to 6.0 kW, the maximum difference in height between the inside
and the outside part is 8 metres. For units with a capacity > 6.0 kW, the maximum difference in
height between the inside and the outside part is 20 metres.
Figure 3
15 (5.9 in) ≥
12 (4.75 in) ≥
12 (4.75 in) ≥
2.3 (90.55 in) ≥
5.1 Determining the location of the exterior unit
•
Install the outdoor unit on a rigid base to prevent increasing noise level and vibration.
G
NOTE
The outdoor unit produces sound when in use, this could interfere with local legislation. It
is the responsibility of the user to check and to make sure the equipment is in full compliance
with local legislation.
•
Determine the air outlet direction where the drainaged air is not blocked.
•
Take the air conditioner weight into account.
•
If an awning is built over the outdoor unit to prevent direct sunlight or rain exposure, make sure that
heat radiation from the condenser is not restricted.
•
Ensure that the clearance around the back of the unit is more than 30 cm and left side is more than 30
cm. The front of the unit should have more than 200 cm of clearance and the connection side (right
side) should have more than 60 cm of clearance. See picture 4.
•
Be sure to level the outdoor unit
4
24
Instal_S70xx ('21) V1.indd 24
Instal_S70xx ('21) V1.indd 24
08-11-2021 18:12
08-11-2021 18:12
Summary of Contents for S 7026
Page 17: ...6 17 Instal_S70xx 21 V1 indd 17 Instal_S70xx 21 V1 indd 17 08 11 2021 18 12 08 11 2021 18 12 ...
Page 49: ...u 49 Instal_S70xx 21 V1 indd 49 Instal_S70xx 21 V1 indd 49 08 11 2021 18 12 08 11 2021 18 12 ...
Page 65: ... 65 Instal_S70xx 21 V1 indd 65 Instal_S70xx 21 V1 indd 65 08 11 2021 18 12 08 11 2021 18 12 ...
Page 66: ...66 Instal_S70xx 21 V1 indd 66 Instal_S70xx 21 V1 indd 66 08 11 2021 18 12 08 11 2021 18 12 ...
Page 67: ...67 Instal_S70xx 21 V1 indd 67 Instal_S70xx 21 V1 indd 67 08 11 2021 18 12 08 11 2021 18 12 ...