order, has been properly maintained and that any associated electrical components are sealed to prevent
ignition in the event of a refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the
relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
lf compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable
level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process
shall be carried out prior to returning the compressor to the suppliers. Only electric healing to the compressor
body shall be employed to accelerate this process. When oil is drained from a system, il shall be carried out
safely.
B
PART NAMES
INDOOR UNIT
Indoor unit
a
Air filter (pull out)
b
Front panel
c
Louver
d
Display window
e
Remote controller
OUTDOOR UNIT
Outdoor unit
f
Connecting pipe, drain hose (For
S-models connecting pipe not included)
g
Air inlet (side and rear)
h
Air outlet
5
6
7
8
2
1
4
3
G
NOTE!
All the pictures in this manual and on the gift box are for explanation and indication purpose only.
They may be slightly different from the air conditioner you purchased. The actual shape shall prevail.
Q_man_S(C)46xx-S(C)54xx–S(C)JAxx22 SCAN ('21) V1.indd 39
Q_man_S(C)46xx-S(C)54xx–S(C)JAxx22 SCAN ('21) V1.indd 39
02-11-2021 11:32
02-11-2021 11:32