background image

2

3

L1

L2

L3

STG40L : DC 
STG40LF : DC 

STG40L-BZ : DC 

STG40L : AC 
STG40LF-BZ : DC 

STG40LF : AC 
STG40L-BZ : AC 

STG40LF-BZ : AC 

L1

12

50

12.

5

L2

12

92

12.

5

L3

12

155

12.

5

STG40ML : DC 
STG40MLF : DC 

STG40ML-BZ : DC 

STG40ML : AC 
STG40MLF-BZ : DC 

STG40MLF : AC 
STG40ML-BZ : AC 

STG40MLF-BZ : AC 

13.

5

30

28.

5

200

62

28.

5

200

104

28.

5

200

167

13.

5

30

13.

5

30

13.

5

30

13.

5

30

13.

5

30

M18x1.5 THREAD

BUZZER VOLUME

CONTROL LEVER

BUZZER VOLUME

CONTROL LEVER

360°/3-M4 BOLT

PCD 30

M18x1.5 THREAD

BUZZER VOLUME

CONTROL LEVER

BUZZER VOLUME

CONTROL LEVER

Ø14 CABLE ENTRY

Ø14 CABLE ENTRY

360°/3-M4 BOLT

PCD 30

L1

12

50

12.

5

13.

5

12.

5

L2

12

70

13.

5

30

30

13.

5

30

12.

5

L3

12

138

13.

5

30

13.

5

30

13.

5

30

L1

L2

L3

28.

5

200

62

28.

5

200

82

28.

5

200

150

STG50L : DC 
STG50LF : DC 

STG50L-BZ : DC 

STG50L : AC 

STG50LF-BZ : DC 

STG50LF : AC 
STG50L-BZ : AC 

STG50LF-BZ : AC 

STG50ML : DC 
STG50MLF : DC 

STG50ML-BZ : DC 

STG50ML : AC 

STG50MLF-BZ : DC 

STG50MLF : AC 
STG50ML-BZ : AC 

STG50MLF-BZ : AC 

LAYER

1
2
3
4
5

L1

334
364
394
424
454

L2

376
406
436
466
496

L3

439
469
499
529
559

LAYER

1
2
3
4
5

L1

106
136
166
196
226

L2

148
178
208
238
268

L3

211
241
271
301
331

LAYER

1
2
3
4
5

L1

334
364
394
424
454

L2

354
384
414
444
474

L3

422
452
482
512
542

LAYER

1
2
3
4
5

L1

106
136
166
196
226

L2

126
156
186
216
246

L3

194
224
254
284
314

Ø50

Ø50

Ø50

Ø18

Ø18

Ø18

Ø50

Ø50

Ø50

Ø18

Ø18

Ø18

Ø40

Ø40

Ø40

Ø40

Ø40

Ø40

• 

STG40(M)L

• 

STG50(M)L

Dimensions

(Units : mm)

Summary of Contents for STG40

Page 1: ...or damage to the product fire and electric shock Precautions for Correct Use Failure to follow the proper instructions may cause damage to property the product and or malfunction of the product that...

Page 2: ...teady STG40ML BZ Steady w built in buzzer STG40MLF Steady Flashing STG40MLF BZ Steady Flashing w built in buzzer 1 AC DC12V AC DC24V AC110V 220V 0 075A 0 045A Max 0 040A 0 12kg 0 12kg 0 14kg 0 14kg R...

Page 3: ...12 5 13 5 12 5 L2 12 70 13 5 30 30 13 5 30 12 5 L3 12 138 13 5 30 13 5 30 13 5 30 L1 L2 L3 28 5 200 62 28 5 200 82 28 5 200 150 STG50L DC STG50LF DC STG50L BZ DC STG50L AC STG50LF BZ DC STG50LF AC ST...

Page 4: ...ding to your product s type and voltage setting DC steady type cable specification External power signal line UL1007 AWG22 0 3sq 400mm AC steady AC DC steady flashing type cable specification External...

Page 5: ...nsistor please choose between the NPN or PNP type transistor which best matches the voltage and product type then connect them correctly according to the wiring diagrams below Wiring using transistor...

Page 6: ...le In case the contact point is damaged it may cause a contact failure Cautions Contact Point Parts Definition How to Change Lens Kit Housing ABS Sound volume lever Pipe Al Lens AS Installation Enviro...

Page 7: ...the right as shown in the diagram to the left Max 85 4dB m Mounting Accessories Sold Separately Please refer to the dimensions below for installation of mounting brackets STG40ML STG50ML Direct Mounti...

Page 8: ...PCD 73 18 18 32 34 24 70 51 M18x1 5 THREAD 75 52 69 18 18 66 52 38 34 46 50 58 28 1 2 PF 4 5 HOLES 12x22 CABLE ENTRY 70 50 18 4 5 HOLES PCD 56 60 57 4 5 5 HOLES 19 CABLE ENTRY 18 90 PCD 73 4 5 5 HOLE...

Page 9: ...ing the sky Sounder part shall not be facing the sky BEACON SIGNALING LIGHT Power cord inlet part shall not be facing the sky Power cord inlet part shall not be facing the sky SIGNAL TOWER LIGHTS HEAV...

Page 10: ...MEMO...

Page 11: ...MEMO...

Page 12: ...China Tel 86 21 6651 7100 Fax 86 21 6315 3929 China Factory Site 2 Qidong 33 Haiyan Road Qidong High tech Industrial Development Zone Qidong Jiangsu Province China Tel 86 513 8384 9999 Fax 86 513 838...

Reviews: