background image

PB

1

Steady/Flashing LED Tower Lights

STG40/ STG50

STG40/ 50(M)L

-

3

-

110/220

-

RAG

-

LW18

[Model number]

[Layer count]

[Voltage]

[Color]

[Mounting option]

|

|

|

|

|

• 

STG40/ 50ML

• 

STG40/ 50ML-BZ

• 

STG40/ 50MLF

• 

STG40/ 50MLF-BZ

• 

STG40/ 50L

• 

STG40/ 50L-BZ

• 

STG40/ 50LF

• 

STG40/ 50LF-BZ

• 1 Layer

• 2 Layers

• 3 Layers

• 4 Layers

• 5 Layers

• 

12-DC12V

• 

24-DC24V

• 

110/220 - AC110V~220V

R-Red

A-Amber

G-Green

B-Blue

W-White

• (Blank)

  -

 

Standard type

• Mounting type 

  

- LB18     - LW18

  

 

- QZ18    - SZ18

  

 

- QL18    - SL18

  

 

- QLA18

Thank you for purchasing Qlight’s products. Please read this user manual carefully 

prior to installation and operation to ensure safe and correct use.

Precautions for Safety  

Failure to follow the instructions below may cause a loss of life or serious physical injury.

1. Please remove any objects that can interrupt ventilation around the product. 

2. Please turn off the power of the product immediately if it fails to operate properly. 

3. Carefully wire the product according to each product’s specification. 

4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product. 

5. Do not apply excessive force/impact to the product. 

6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.

Precautions for Correct Use 

Failure to follow the proper instructions may cause damage to property, the product, and or malfunction of  the 

product that would void the warranty. 

1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)

2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection 

    ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury, 

    malfunction or damage to the product.)

3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to 

    follow these instructions may lead to fire, electric shock, or product damage.)

4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)

5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to 

    follow this may cause damage to property, fire, electric shock and loss of life.)

Ordering Specifications

Please scan the QR code for more 

detailed product information.

www.qlight.com

54

65

85dB

50

30

Summary of Contents for STG40

Page 1: ...or damage to the product fire and electric shock Precautions for Correct Use Failure to follow the proper instructions may cause damage to property the product and or malfunction of the product that...

Page 2: ...teady STG40ML BZ Steady w built in buzzer STG40MLF Steady Flashing STG40MLF BZ Steady Flashing w built in buzzer 1 AC DC12V AC DC24V AC110V 220V 0 075A 0 045A Max 0 040A 0 12kg 0 12kg 0 14kg 0 14kg R...

Page 3: ...12 5 13 5 12 5 L2 12 70 13 5 30 30 13 5 30 12 5 L3 12 138 13 5 30 13 5 30 13 5 30 L1 L2 L3 28 5 200 62 28 5 200 82 28 5 200 150 STG50L DC STG50LF DC STG50L BZ DC STG50L AC STG50LF BZ DC STG50LF AC ST...

Page 4: ...ding to your product s type and voltage setting DC steady type cable specification External power signal line UL1007 AWG22 0 3sq 400mm AC steady AC DC steady flashing type cable specification External...

Page 5: ...nsistor please choose between the NPN or PNP type transistor which best matches the voltage and product type then connect them correctly according to the wiring diagrams below Wiring using transistor...

Page 6: ...le In case the contact point is damaged it may cause a contact failure Cautions Contact Point Parts Definition How to Change Lens Kit Housing ABS Sound volume lever Pipe Al Lens AS Installation Enviro...

Page 7: ...the right as shown in the diagram to the left Max 85 4dB m Mounting Accessories Sold Separately Please refer to the dimensions below for installation of mounting brackets STG40ML STG50ML Direct Mounti...

Page 8: ...PCD 73 18 18 32 34 24 70 51 M18x1 5 THREAD 75 52 69 18 18 66 52 38 34 46 50 58 28 1 2 PF 4 5 HOLES 12x22 CABLE ENTRY 70 50 18 4 5 HOLES PCD 56 60 57 4 5 5 HOLES 19 CABLE ENTRY 18 90 PCD 73 4 5 5 HOLE...

Page 9: ...ing the sky Sounder part shall not be facing the sky BEACON SIGNALING LIGHT Power cord inlet part shall not be facing the sky Power cord inlet part shall not be facing the sky SIGNAL TOWER LIGHTS HEAV...

Page 10: ...MEMO...

Page 11: ...MEMO...

Page 12: ...China Tel 86 21 6651 7100 Fax 86 21 6315 3929 China Factory Site 2 Qidong 33 Haiyan Road Qidong High tech Industrial Development Zone Qidong Jiangsu Province China Tel 86 513 8384 9999 Fax 86 513 838...

Reviews: