3
External contact
Transistor
AC
Steady
AC
Steady/
Flashing
• DC steady type cable specification: External power/ signal line - UL1007 AWG22(0.3sq) 400mm
• AC steady, AC/DC steady/flashing type cable specification : External power line - UL1015 AWG18(0.75sq) × 2C 400mm
External signal line - UL1007 AWG22(0.3sq) 400mm
EXTERNAL TRANSISTOR-NPN
EXTERNAL TRANSISTOR-NPN
Common
Common
Common
SWTC(E)L-AC
SWTC(E)LF-AC
SWTC(E)LF-AC
SWTC(E)L-AC
EXTERNAL CONTACT
EXTERNAL CONTACT
Red
Amber
Green
Red
Amber
Green
Buzzer
Buzzer
Power
Power
Steady
Steady
Steady
Fuse
Fuse
Fuse
Red
Amber
Green
Brown
Black
White
Black
Red
Amber
Green
Brown
Black
White
Black
Common
Red
Amber
Green
Buzzer
Red
Amber
Green
Red
Amber
Green
Buzzer
Red
Amber
Green
Brown
Gray
Black
White
Black
Power
Steady
Flash
Red
Amber
Green
Brown
Black
Gray
White
Black
Power
Common
Common
Flash
Fuse
Parts Definition/ Installation
• Remove the cove
r ②
by loosening the housing
①
.
•
Machine taps or holes on the mounting surfac
e
⑤
.
•
The mounting hole of this product is 4.2mm in diameter(hole).
•
When machining taps, fasten the bolt through the mounting hole of the product.
•
When machining holes, insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting
surface.
• Insert hook
③
under cover and press hook
④
on top of cover.
①
Housing (ABS)
Bolt
Cove
r
(ABS)
Chromium Plating
(ABS) - SWTC only
②
⑤
④
③
①
②
Summary of Contents for SWTCL
Page 6: ...MEMO...