Qlight SEBA Quick Start Manual Download Page 3

3

• First, machine taps or holes on the mounting surface 

.

• The mounting hole of this product is 8.5mm in diameter.

• When machining taps, fasten the bolt through the mounting hole of  the product. 

• When machining holes, insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting surface.

■ 

Installation

Protection cage 

(STS316L)

Lens(Tempered glass)

Housing(Al)

Bell(Al)

• • 

Please refer to the chart below to use light function 

  selection switch located inside the product.

• Default function is set at steady LED. Select the desired function 

  for your application during installation. 

4-Ø9 HOLES

134

134

• 

Please use an M4 bolt at the location marked 

  in the diagram above to ground the product. 

• 

When connecting the grounding cable, 

  please use a ring terminal.

• Please use a grounding cable with a diam-

  eter greater than 4mm.

Terminal Box Wiring Instructions

• Terminal block is located inside of the product. Unscrew the 4 bolts located in the upper body to

   get rid of the upper lighting element of the unit.

• Please apply fork (U-type) or ring (O-type) locking spade terminal at naked tip of the wire for

   secure connection.

• Please wire the power line to terminal 

①.

• For AC type products, wire regardless of polarity.

• For DC type products, wire terminal of black line to (-) polarity.

• Once the unit is powered on, light and bell are working simultaneously. 

Parts Definition/ Installation/ 

Light Function Selection

▶LF : 

Flashing

■ 

Light Function Selection(SEBAL only)

▶L : 

Steady

■ Parts Definition

Grounding Instructions

Mounting Hole Specifications

• Machine holes on the mounting surface referring to 

  the diagram below.

M4 ground contact part