3

• Machine holes on the mounting surface referring to 

  the diagram below.(S100S only)

■ 

Mounting Hole Specifications

PCD 60

3-Ø5 HOLES

S100S

Mounting Hole Specifications/ Xenon Bulb Replacement lnstructions

Mounting Accessories (Sold Separately)

Dimensions

S100S

SWP125

SWM125

• Please refer to the dimensions below for installation of mounting brackets

Ø22

Ø22

Ø10 CABLE ENTRY

6-Ø5.5 HOLES

360°/ 3-

Ø5.5 HOLES

6-Ø5.5 HOLES

4-Ø5.5 HOLES

Ø10 CABLE ENTRY

4-Ø5.5 HOLES

360°/ 3-

Ø5.5 HOLES

70

94

69

11.5

26.5

117

PCD5

0

PCD85

PCD60~70

70
90

65

115

11.5

26.5

PCD50

PCD85

PCD60~70

■ 

Xenon Bulb Replacement instructions

• 

Please wait at least 30 mimutes after turning off the power 

  before replacing the xenon bulb.

• Please pull out the entire xenon bulb structure 

① 

to disas

  semble.

• For xenon bulb assembly, please ensure the connector portion 

  of the xenon bulb structure matches the pin location

②.

Disassemble 

bulb

Assemble bulb

Installation Environment and Protection Rating

• This product is designed for use with protection rating of IP54.

• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating 

   indicated(IP54), it may cause malfunction or damage to the product.

• In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside-

  down positions where water can potentially penetrate into the product and impact it’s operation.

• For further information, please visit our website (www.qlight.com).

Summary of Contents for S100S

Page 1: ... force impact to the product 6 Failure to follow any of the instructions above may cause malfunction or damage to the product fire and electric shock Precautions for Correct Use Failure to follow the proper instructions may cause damage to property the product or malfunction of the product that would void the warranty 1 During wiring or maintenance please completely turn off the power of the produ...

Page 2: ...rette lighter plug External power line IEC42 0 75sq x 2P 2 000mm S100SM External power line UL1015 AWG18 0 75sq x 2C 400mm S100S This product can be wired regardless of polarity S100SM models please connect the cigarette lighter plug of the product to a cigarette lighter socket of a vehicle S100SM S100S Ø101 Ø101 Ø10 CABLE ENTRY Ø10 CABLE ENTRY 113 15 92 12 113 92 15 0 75sq x 2P 2m PCD 60 360 3 M4...

Page 3: ...f the power before replacing the xenon bulb Please pull out the entire xenon bulb structure to disas semble For xenon bulb assembly please ensure the connector portion of the xenon bulb structure matches the pin location Disassemble bulb Assemble bulb Installation Environment and Protection Rating This product is designed for use with protection rating of IP54 If the product is installed in locati...

Page 4: ...i China Tel 86 21 6651 7100 Fax 86 21 6315 3929 China Factory Site 2 Qidong 33 Haiyan Road Qidong High tech Industrial Development Zone Qidong Jiangsu Province China Tel 86 513 8384 9999 Fax 86 513 8384 9910 Product Operation Inquiry Customer Support 82 51 620 4100 You can expect prompt service if you have exact information such as model name symptom telephone number and address ALL PRODUCT PRODUC...

Reviews: