![Qlight QEAL1 Instruction Manual Download Page 4](http://html1.mh-extra.com/html/qlight/qeal1/qeal1_instruction-manual_3259930004.webp)
4
Installation Environment and Protection Rating
Mounting Hole Specifications
• This product is designed for use with protection rating of IP66.
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated(IP66), it may cause malfunction or damage to the product.
• For further information, please visit our website(www.qlight.com).
• Machine holes on the mounting surface referring to the diagram below.
• Product with built-in ambient light sensor is available upon request.
- Ambient light sensor activates the lighting system and automatically
operates the product when darkness is detected.
- Ambient light sensor is located in location
①
. Please be careful to keep
the outside lens clean and prevent obstacles from obstructing the ambient light sensor
■
Built-in Ambient Light Sensor Model
①
①
Terminal Box Wiring Instructions
• Terminal block is located inside of the product. Unscrew the 4 bolts located in the upper
body to get rid of the upper lighting element of the unit.
• Please apply fork (U-type) or ring (O-type) locking spade terminal at naked tip of the wire
for secure connection.
• Please wire the power line to terminal
①
• For AC type products, wire regardless of polarity.
• For DC type products, wire terminal of black line to (-) polarity.
• External power line -
UL1015 AWG18(0.75sq) x 2C 400mm
4-Ø9 HOLES
114
114
※
Applicable cable range : AWG16-AWG22
Summary of Contents for QEAL1
Page 6: ...MEMO...
Page 7: ...MEMO...