Setup

New locks operate with the default user and master codes. A new user 

and master code must be programmed to prevent the default codes 

from operating the lock and reducing lock security.    

Master Code Functions:

1)Open: Enter master code  

(The user code will be deleted when using master code when the lock is 

in public mode)

2) Programming Master Code

Press *--current master code 

-#--01--#--- new master code - -#--new 

master code--#

Example: *

20050330

#---12345678--#--12345678--#

Result: Master code has been changed to 12345678

3) Set or change the sub-master Code

Press *

- master code---#--04---new sub-master code---#

4) Delete sub-master code

Press *--Master code---#-05--#

5) Set or change the User Code (Private Mode)   

Press * 

master code - -#- -02--- new user code - -# 

Example: *--20050330--#-02 --1234--#

Result: New user code 1234 now operative

6) Delete User code(Private Mode)   

Press *--Master code--#--03-- #

7)Set or change the Technician code  (Public Mode) 

Press*--Master code--#--08--#--new technician code--#

Note: the technician code must be 6 digit code 

8)Delete the Technician code (Public Mode)  

Press *--Master code--#--09--#

9)Activate/Deactivate the Auto-unlock Function  (Public Mode) 

Activate:Press *--Master code--#--11--#

Deactivate: Press*--Master code--#--12--#

10)Set Auto-open time  (Public Mode) 

Press *--Master code--#--10--#--XX--#

Example: Press*--20050330#--10#-02#, the door unlock in 2 hours later

Note: until the door locked, the lock  begins to count and unlock 2 two 

hours later and the “xx” is from 01 to 12 

Summary of Contents for MK731

Page 1: ...MK731 DIGITAL COMBINATION LOCK ...

Page 2: ... Page 1 of 4 Metal Lock Horizontal Vertical Models Different Colour options available upon request Easy to set Change Code Master Key for Emergency Opening Switch between Private and Public mode easily Easy to installation Rector fit existing Punch Hole 19 x 16 1mm mechanical locks Meets IP55 rating ...

Page 3: ... Mode Note this is the default function and is already pre programmed into each lock This is the most common mode and is used where the same code will be repeatedly used To set to Private Mode Master code 07 Example 20050330 07 Result The lock will revert back to default Private Mode factory set user code 1111 will now work until reprogrammed Public Mode This function is used for short term multi ...

Page 4: ...w sub master code 4 Delete sub master code Press Master code 05 5 Set or change the User Code Private Mode Press master code 02 new user code Example 20050330 02 1234 Result New user code 1234 now operative 6 Delete User code Private Mode Press Master code 03 7 Set or change the Technician code Public Mode Press Master code 08 new technician code Note the technician code must be 6 digit code 8 Del...

Page 5: ...aster code 3 Set Change the User Code Private Mode Press current sub master code 02 new user code User Code Function Private Mode Open Enter user code 2 Change the User Code Press current user code new user code Public Mode Set code enter any 4 digit code Open Enter user code Note The 4 digit code is one time valid only The door keep open until another one set a new code Initialize 99 Press the re...

Page 6: ... to replace the batteries COMPANY REG 6535355 VAT NO GB 936 5596 78 Page 4 of 4 Additional Functions Occupied Status Indicator Public Mode deactivated by default When activated the green light will flash every 6 seconds to indicate the locker is in use Activate Press Master code 13 Deactivate Press Master code 14 Password protection deactivated by default Entering incorrect codes 5 times will caus...

Page 7: ...Qi LOCKS LIMITED Unit 14 Stephenson Court Priory Business Park Bedford MK44 3WJ 0330 311 1003 sales qilocks com www qilocks com ...

Reviews: