![QHT Air Compressor User Manual Download Page 14](http://html1.mh-extra.com/html/qht/air-compressor/air-compressor_user-manual_3145130014.webp)
11
3.1 B-10 Burner Setup
Boiler Model
B10-3
B10-4
B10-5
B10-6
Burner Model
BF-3
BF-3
BF-5
BF-5
Firing Rate
0.55
0.80
1.00
1.25
Insertion Depth
3.0”
3.0"
3.0"
3.0"
Nozzle
.4 X 80
.65 X 80
.85 X 60
1.00 X 60
Spray Pattern
W
W
W
W
Pump Pressure
180 psi
175 psi
150 psi
175 psi
Turbulator
2
3
2
3
Air Gate
3.2
4.7
3.4
5
BURNER MANUFACTURER Riello
BF3 and BF5
BURNER MANUFACTURER
Heat Wise
Pioneer
Boiler Model
B-13
B-14
B-15
B-16
Burner Model
P-1 KFV*
P-1 KA
P-1 KA
P-2 KA
Firing Rate
0.55
0.90
1.00
1.25
Insertion Depth
3.5”
3.5”
3.5”
3.5”
Nozzle
0.40 X 80
0.65 X 70
0.85 X 70
1.00 X 80
Spray Pattern
Solid
Solid
Semi Solid
Hollow
Pump Pressure
200
200
150
190
Head Setting
1
1
1
3.75
Air Setting
0
9.5
16.5
6
*120mm Fan Needed
BURNER MANUFACTURER
Beckett
AFII - 150 (NEC 301, 302, 303) , NX (NEC 1101, 1102, 1103)
Boiler Model
B10 - 4*
B10 - 5*
Burner Model
NEC - 301 NEC - 1101 NEC - 302 NEC - 1101 NEC - 303 NEC - 1103
Firing Rate
0.80
0.90
1.00
1.00
1.25
1.20
Insertion Depth
2.75”
6.0”
2.75”
6.0”
2.75”
6.0”
Nozzle
.65 X 60
o
.65 X 60
o
.85 X 60
o
.75 X 60
o
1.00 X 60
o
.90 X 60
o
Spray Pattern
hollow
solid
solid
solid
solid
W
Pump Pressure
160 psi
180 psi
140 psi
180 psi
160 psi
180 psi
Head Type
6 slot
9 slot
6 slot
9 slot
9 slot
9 slot
Head Position
3
3
4
4
5
4.25
Air Setting
3
N/A
3.75
N/A
6
N/A
B10 - 6*
B10 - 3*
NEC - 1102
0.55
3.5”
.40 X 60
o
hollow
180 psi
6 slot
1.25
N/A
* - These burners may not be used in Canada on Biasi equipment