29. POSITIONING OF TILE SAW See
FIGURE 1
A. To avoid the possibility of the appliance plug or
receptacle getting wet, position the tile saw to
one side of a wall-mounted receptacle to prevent
water from dripping onto the receptacle or plug.
The user should arrange a “drip loop” in the cord
connecting the saw to a receptacle. The “drip
loop” is that part of the cord below the level of
the receptacle, or connector if an extension cord
is used, to prevent water traveling along the cord
and coming in contact with the receptacle.
B.
If the plug or receptacle does get wet,
DO NOT
unplug the cord. Disconnect the fuse or circuit
breaker that supplies power to the tool. Then,
unplug and examine for presence of water in
the receptacle.
30.
CHECK DIAMOND BLADES CAREFULLY
for cracks,
nicks, missing diamond matrix, or out-of-alignment.
Replace blades immmediately.
DO NOT
use damaged
blades. They may cause bodily injury.
ELECTRICAL REQUIREMENTS
•
THIS TILE SAW MUST BE CONNECTED TO A GROUNDED POWER SOURCE
while in use to protect the
operator from electrical shock.
•
IN THE EVENT OF A MALFUNCTION OR BREAKDOWN,
grounding provides a path of least resistance for
electrical current to reduce the risk of electrical shock. The tile saw is equipped with an electrical cord with a
grounding conductor and a grounding plug. Insert the 3-prong electrical plug into a 3-pole receptacle that is
properly installed and grounded in accordance with all local codes and ordinances.
•
DO NOT MODIFY THE PLUG
provided if it will not fit the outlet. Have the proper outlet installed by a
qualified electrician.
•
IMPROPER CONNECTION OF THE EQUIPMENT-GROUNDING CONDUCTOR CAN RESULT IN A RISK OF
ELECTRIC SHOCK.
The conductor with insulation that is green on the outside (with or without yellow stripes)
is the equipment-grounding conductor. If repair or replacement of the electrical cord or plug is necessary, do
not connect the equipment-grounding conductor to a live terminal.
•
CHECK WITH A QUALIFIED ELECTRICIAN
or service personnel if the grounding instructions are not
completely understood, or if in doubt as to whether the tool is properly grounded.
•
USE ONLY 3-WIRE EXTENSION CORDS
that have 3-prong grounding plugs and 3-pole receptacles that
accept the tile saw’s plug.
•
REPAIR OR REPLACE DAMAGED OR WORN CORD IMMEDIATELY.
•
IF THE PLUG OR RECEPTACLE DOES GET WET, DO NOT UNPLUG THE CORD.
Disconnect the fuse or circuit
breaker that supplies power to the tool. Then, unplug and examine for presence of water in the receptacle.
•
ONLY UL-LISTED EXTENSION CORDS SHOULD BE USED WITH THIS PRODUCT.
•
IMPROPER USE OF EXTENSION CORDS MAY CAUSE INEFFICIENT OPERATION OF YOUR TOOL,
which can
result in overheating. Be sure your extension cord is
rated to allow sufficient current flow to the motor. For
the proper gauge for this tile saw, please refer to
TABLE 1
.
•
DO NOT LET YOUR FINGERS TOUCH THE TERMINALS
of plug when installing or removing the plug to or from
the outlet.
•
THIS TILE SAW MUST BE PROPERLY GROUNDED.
The
risk of electric shock and bodily injury are greatly
increased if it is not, particularly when used in damp
locations or in proximity to plumbing.
NOTE:
This tool is intended for use on a circuit that has an
- 4 -
(B) GROUNDED OUTLET BOX
METAL SCREW
FIGURE 2
(A) GROUNDING PIN
(Not Permitted In Canada)
(C) GROUNDING ADAPTER
DRIP LOOP
POWER SUPPLY
CORD
TILE SAW
SUPPORTING
SURFACE
FIGURE 1