FOR YOUR OWN SAFETY READ INSTRUCTION
MANUAL BEFORE OPERATING SAW.
• Wear eye protection.
• Use splash hood for every operation for
which it can be used.
• Unplug saw before servicing, when changing
cutting wheels, and cleaning.
• Use tool only with smooth-edge cutting
wheels free of openings and grooves.
• Replace damaged cutting wheel
before operating.
• Do not fill water tray above water fill line.
ELECTRICAL
REQUIREMENTS
1.
ThIS TILE SAW muST bE ConnECTEd To
A GroundEd poWEr SourCE
while in use to
protect the operator from electrical shock.
2.
In ThE EvEnT of A mALfunCTIon or
brEAKdoWn,
grounding provides a path
of least resistance for electrical current to
reduce the risk of electrical shock. The tile
saw is equipped with an electrical cord with
a grounding conductor and a grounding plug.
Insert the 3-prong electrical plug into a 3-pole
receptacle that is properly installed and
grounded in accordance with all local codes
and ordinances.
3.
do noT modIfy ThE pLuG
provided if it
will not fit the outlet. Have the proper outlet
installed by a qualified electrician.
4.
ImpropEr ConnECTIon of ThE
EquIpmEnT-GroundInG ConduCTor CAn
rESuLT In A rISK of ELECTrIC ShoCK.
The
conductor with insulation that is green on the
outside (with or without yellow stripes) is the
equipment-grounding conductor. If repair or
replacement of the electrical cord or plug is
necessary, do not connect the equipment-
grounding conductor to a live terminal.
5.
ChECK WITh A quALIfIEd ELECTrICIAn
or
service personnel if the grounding instructions
are not completely understood, or if in doubt
as to whether the tool is properly grounded.
6.
uSE onLy 3-WIrE EXTEnSIon CordS
that
have 3-prong grounding plugs and 3-pole
receptacles that accept the tile saw’s plug.
7.
rEpAIr or rEpLACE dAmAGEd or Worn
Cord ImmEdIATELy.
8.
If ThE pLuG or rECEpTACLE doES GET
WET, do noT unpLuG ThE Cord.
Disconnect
the fuse or circuit breaker that supplies power
to the tool. Then, unplug and examine for
presence of water in the receptacle.
9.
onLy uL-LISTEd EXTEnSIon CordS
ShouLd bE uSEd WITh ThIS produCT.
10.
ImpropEr uSE of EXTEnSIon CordS
mAy CAuSE InEffICIEnT opErATIon of
your TooL,
which can result in overheating.
Be sure your extension cord is rated to allow
sufficient current flow to the motor. For the
proper gauge for this tile saw, please refer
to TABlE 1.
11.
do noT LET your fInGErS TouCh
ThE TErmInALS
of plug when installing or
removing the plug to or from the outlet.
12.
ThIS TILE SAW muST bE propErLy
GroundEd.
The risk of electric shock and
bodily injury are greatly increased if it is not,
particularly when used in damp locations or in
proximity to plumbing.
noTE:
This tool is intended for use on a
circuit that has an outlet that looks like the
one illustrated in FIGURE 2 (A). The tool has
a grounding plug that looks like the plug
illustrated in FIGURE 2 (A). A temporary
adapter, which looks like the adapter
illustrated in FIGURE 2 (B) and (C), may be used
to connect this plug to a 2-pole receptacle
as shown in FIGURE 2 (B) if a properly
grounded outlet can be installed by a qualified
electrician. The green-colored rigid prongs
extending from the adapter must be connected
to a permanent ground such as a properly
grounded outlet box.
(C) Grounding adapter
(not permitted in Canada)
(A) Grounding
pin
Metal
screw
(B) Grounding outlet box
fIGurE 2