background image

Quality in Electronic Manufacturing

Pag. 5 di 27

HB 237.16

Instrument

release

Manual

release

0

0

New manual

01 / 03 / 97

Modifications to manual

Date of

modifications

1 - 3 RESPONSIBILITY AND VALIDITY

RESPONSIBILITY

QEM declines all responsibility for any injury to persons or damage to things resulting from the failure to observe the

instructions and rules in this manual and the "Installation, maintenance and servicing manual". It is furthermore

specified that the customer/purchaser is bound to use the instrument according to the instructions provided by QEM

and, if any doubts arise, to send a written query to QEM. Any authorisation for exceptions or substitutions, if contested,

will be deemed valid by QEM only if written consent has been given by QEM.

The reproduction or transfer of all or part of this manual to third parties is forbidden without QEM's written consent.

Any transgression will result in a claim for compensation for the damages sustained.

All rights deriving from patent or designs are reserved.

QEM reserves the right to make partial or complete modifications to the characteristics of the instrument described

and the corresponding documentation.

Objective

The objective of this manual is to give the general rules for the use of the instrument described.

Recommendation

Write down all the instrument setting and programming parameters, keeping them in a safe place to facilitate any future

replacement or servicing operations.

VALIDITY

This manual is applicable to all instruments designed, manufactured and tested by QEM with the same order code.

This document is valid in its entirety, save errors or omissions.

Summary of Contents for HB 237.16

Page 1: ...ent to Installation maintenance and servicing manual POSITION CONTROLLER WITH POSITIVE AND NEGATIVE QUOTAS AND MANAGEMENT OF 8 OUTPUTS PROGRAMMABLE WITH UP TO 9 PROGRAMS HB 237 16 OHFWURQLF QVWUXPHQW PRG SET b 2 3 7 H 1 6 ...

Page 2: ...escription of operation 1 4 CHAP 2 OPERATOR MACHINE INTERFACE Description of keyboard 2 1 Description of inputs 2 2 Description of outputs 2 3 CHAP 3 SETTING UP FOR OPERATION Programming set up 3 1 CHAP 4 USE Work programs and auxiliary functions 4 1 Operation graphs and tables 4 2 CHAP 5 ASSISTANCE Inputs and outputs troubleshooting 5 1 How to complete the technical assistance fax form 5 2 Warran...

Page 3: ...Quality in Electronic Manufacturing Pag 3 di 27 HB 237 16 CHAPTER 1 Supplementary nature of manual References Responsibility and validity Description of operation INTRODUCTION ...

Page 4: ...e understanding programming calibration and use of the instrument described Once the instrument is installed following the indications given in the Installation maintenance and servicing manual this user manual gives all the necessary information for the correct use and programming of the instrument Installation maintenance and servicing manual All the necessary information for installation mainte...

Page 5: ... written consent has been given by QEM The reproduction or transfer of all or part of this manual to third parties is forbidden without QEM s written consent Any transgression will result in a claim for compensation for the damages sustained All rights deriving from patent or designs are reserved QEM reserves the right to make partial or complete modifications to the characteristics of the instrum...

Page 6: ...PTION OF OPERATION The instrument HB 237 16 controls the position of one axis and governs the activation and de activation of 8 totally programmable outputs The quotas for each single output can be set in a maximum of 9 programs that can be called only from the keyboard ...

Page 7: ...Quality in Electronic Manufacturing Pag 7 di 27 HB 237 16 CHAPTER 2 Description of keyboard Description of inputs Description of outputs OPERATOR MACHINE INTERFACE ...

Page 8: ...for two seconds displays input output diagnostics Data input increases impulsively or continuously the figure selected on the display the one that flashes Normal operation not used Data input moves to the left the selection of the figure displayed Lighted when programming set up parameters Lighted when introducing work programs Not used Not used When lighted indicates possibility of introducing th...

Page 9: ...up parameter By holding down together the keys and ENTER password 732 it is possible to set the input acquisition time Polarizer Operating logic Activation mode Description Key X See description Name Positive transducer supply Positive voltage supplied by the instrument to feed instrument inputs and transducers Negative transducer supply Negative voltage supplied by the instrument to feed inputs a...

Page 10: ...thismanual Name U1 P C1 C Quota 1 With set up parameter LI set on 0 the output is activated when the count reaches the value of the quota set as parameter I in the work program When the set up parameter LI is set on 1 the output is de activated when the count reaches the value of the quota set as parameter I in the work program U2 P C1 C Quota 2 With set up parameter L2 is set on 0 the output is a...

Page 11: ... When the set up parameter L5 is set on 1 the output is de activated when the count reaches the value of the quota set as parameter 5 in the work program U6 P C2 C Quota 6 With set up parameter L6 set on 0 the output is activated when the count reaches the value of the quota set as parameter 6 in the work program When the set up parameter L6 is set on 1 the output is de activated when the count re...

Page 12: ...Quality in Electronic Manufacturing Pag 12 di 27 HB 237 16 CHAPTER 3 SETTING UP FOR OPERATION Programming set up ...

Page 13: ...nstallation maintenance and servicing manual H d 0 Display method Specifiesthenumberoffiguresafterthedecimalpoint withwhich to display the count axis position N B Introduction of decimal figures influences the DISPLAY of the count precision in positioning depends on the number of impulses supplied by the transducer C d 0 Decimal figures Max 3 This parameter indicates by how much the encoder revolu...

Page 14: ...t is interrupted 5 Impulse loading of the preset quota on the count when input I1isde activatedonlywheninputI2isactivatedandparameter F2 is set on 1 fast input is interrupted 6 Continuous zero reset of outputs 7 Program increase 8 Restart program its activation utilises program number 1 F I 0 0 No function 1 Enables preset loading 2 Continuous zero reset of outputs 3 Program increase 4 Restart pro...

Page 15: ...nsenabledforthetimesetintheworkprogram timer1 The count increases UP 3 The output is activated when the count is equal to or greater than the value introduced in the work program quota 1 and remains enabled for the delta set in the work program delta 1 The count increases UP 4 The output is activated when the count is equal to or less than the value introduced in the work program quota 1 The count...

Page 16: ... value introduced in the work program quota 2 and remains enbled for the delta set in the work program delta 2 The count increases UP 4 The output is activated when the count is equal to or less than the value introduced in the work program quota 2 The count decreases DOWN 5 The output is activated when the count is equal to or less than the value introduced in the work program quota 2 and remains...

Page 17: ... work program delta 3 8 The count increases UP 4 The output is activated when the count is equal to or less than the value introduced in the work program quotas 3 8 The count decreases DOWN 5 The output is activated when the count is equal to or less than the value introduced in the work program quotas 3 8 and remains enabled for the time set in the work program timer 3 8 The count decreases DOWN ...

Page 18: ...L 5 0 0 Output U5 is normally de activated 1 Output U5 is normally activated Output U6 logic status L 6 0 0 Output U6 is normally de activated 1 Output U6 is normally activated Output U7 logic status L 7 0 0 Output U7 is normally de activated 1 Output U7 is normally activated Output U8 logic status L 8 0 0 Output U8 is normally de activated 1 Output U8 is normally activated After programming the l...

Page 19: ...Quality in Electronic Manufacturing Pag 19 di 27 HB 237 16 CHAPTER 4 USE Work programs and auxiliary functions Operation graphs and tables ...

Page 20: ...e ENTER key A request is made to introduce the time for activating the second output enabled in set up max 60 00 seconds The operator can introduce its value and confirm with ENTER Examplewithset upparameter FU3 seton 3 whenparameter Ab is set on 1 The current quota 3 flashing is displayed The operator can introduce the quota relative to the third output enabled in set up min 9999 max 9999 and con...

Page 21: ...r disable output U2 0 Output disabled 1 Output enabled The operator can decide whether to enable or disable the output and confirm with ENTER Example with set up parameter FU2 set on 2 The flashing quota 2 currently in use is displayed The operator can introduce the quota relative to the second output enabled in set up min 9999 max 9999 and confirm with ENTER The request is made to introduce the a...

Page 22: ...ess to calibration of acquisition times Introduce access code 732 and confirm with ENTER The display shows the acquisition time for input I2 Every check introduces a delay time of 5 milliseconds When a value of zero is set theinputacquires10checks acquisitiontime50milliseconds The operator can introduce a new value min 0 max 99 and confirmwithENTER Thedisplayreturnstotheonecurrentlyinuse Keyboard ...

Page 23: ...tallation and calibration Description Keyboard Display C 1 2 3 4 Access to introduction of a value on the count The operator can enter the required count value When confirmed with ENTER the count is updated with the new value and the display returns to the one currently in use 2 sec DISPLAYS Description Keyboard Display 1 1 2 3 4 Left display Program in use Right display Count This appears in alte...

Page 24: ...Quality in Electronic Manufacturing Pag 24 di 27 HB 237 16 4 2 OPERATION TABLES AND GRAPHS OUTPUT FUNCTIONS GRAPH ...

Page 25: ...Quality in Electronic Manufacturing Pag 25 di 27 HB 237 16 OUTPUT FUNCTIONS GRAPH ...

Page 26: ...Quality in Electronic Manufacturing Pag 26 di 27 HB 237 16 CHAPTER 5 ASSISTANCE Input and output troubleshooting How to complete the technical assistance fax form Warranty ...

Page 27: ...x form enclosed with the installation maintenance and servicing manual and to send it to the QEM assistance office In this way our service engineers will have all the essential information for understanding your problem avoiding long and costly telephone calls Thanking you for your kind co operation QEM wishes you all the best in your work NOTE If you have to send us an instrument for repair pleas...

Page 28: ...Quality in Electronic Manufacturing Pag 28 di 27 HB 237 16 SPACE FOR YOUR NOTES ...

Reviews: