1) General 

P.3 

 

Before carrying out any work on the fan, disconnect it from the electrical supply! 

 

Check if the electrical specifications of this appliance are compatible with your installation. The supplier 
accepts no responsibility for any physical injury or material damage resulting from incorrect use or 
installation of this fan. If you have the slightest doubt, please contact electrician. 

 

Unauthorized use and technical modifications to the appliance can lead to danger to life and health. 

 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, 
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or 
instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall 
not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision 

 

Children should be supervised to ensure that they do not play with the appliance. 

 

This appliance is for indoor use only. 

 

Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. 

 

Never install the appliance in a moist or wet room. 

 

Be careful when working near the rotating blades. The fan should be installed at least a height of 2.3m 

 

Before pushing the reversible slide switch, it is necessary to stop the action of the blades by turning off the 
fan 

 

Don’t place your arm or other object in the path of the blades, when the fan is operating.

 

 

 Always maintain the minimum distance between the lamp and any inflammable material (curtains, 

wall etc), as indicated on the pictogram 

 

Means for all poles disconnection having a contact separation that provide full disconnection under over 
voltage category III conditions must be incorporated in the fixed wiring in accordance with national wiring 
rules. 

 

Power supply wire from ceiling needs 1.5 sq mm wire 

 

Regarding the method of the cable connection , how to assembly

 and the bulb type reference of a luminaire

thanks to refer to the section “INSTALLATION”

   

 

Warning: Before obtaining access to terminals, all supply circuits must be disconnected. 

 

Summary of Contents for Cool Fan 52

Page 1: ...P 1 INSTRUCTION MANUAL Cool Fan 52 92648 92649 92650 92651 92652 2XE14 MAX40W ...

Page 2: ...hly before using the appliance and save it for future reference and if necessary pass the instruction manual on to a third party WARNING When using electrical appliance basic safety precautions should always be followed to reduce the risk of fire electrical shock and personal injury P 2 Caution ...

Page 3: ...do not play with the appliance This appliance is for indoor use only Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules Never install the appliance in a moist or wet room Be careful when working near the rotating blades The fan should be installed at least a height of 2 3m Before pushing the reversible slide switch it is necessary to stop the actio...

Page 4: ...ecting point for environmentally friendly disposal in accordance with local regulations Contact your local authorities or stockist for advice on recycling The packaging material is recyclable Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection service 5 Appliance specifications TECHNICAL CHARACTERISTICS Rated voltage 220 240 V...

Page 5: ...R TEMPORARY HANG UP THE FAN WHEN WIRING CONNECTION 3 SCREWS 4 SCREWS 5 HANGER BALL 6 UPPER CANOPY 7 DOWNROD 8 SCREW 9 RECTANGULAR COVER 10 SCREWS 11 BLADE 12 UPPER HOUSING 13 LIGHT PLATE 14 BULB not included 15 GLASS 16 Remote Control Receiver 17 Remote Control Transmitter P 5 ...

Page 6: ...ews from the rectangular cover on the motor housing and remove the cover Fig 2 3 Insert the blades through the slots around the motor Fig3 4 Align the blade with the three holes and secure the three screws through the opening Tighten all blade screw evenly and get the rectangular cover secured by screws Fig 4 P 6 ...

Page 7: ...k Brown wire L Blue wire N Green yellow wire The earth wire must longer than Live wire and Neutral wire 6 Hang up the fan and assembly the mounting bracket with the motor set by 4 side screws Fig 6 7 Insert the len into the receiver and connect the supply wires of the receiver Fig7 8 Install the bulb not included Fig 8 P 7 ...

Page 8: ...If the fan or light kit is PARTIALLY pre assembled you can skip the assembly 9 Install the glass Fig 9 10 Now the fan is completed Fig10 P 8 ...

Page 9: ...heater to floor 9 Disconnect from mains before maintenance or cleaning Do not use a wet sponge to clean the appliance 1 Before conducting any cleaning or maintenance work disconnect the power from the electrical supply and wait until lamp cools down 2 No abrasive products solvents detergent or any other liquid may be used to clean the fan or lamp 3 Be sure the power is off when you clean the fan 4...

Page 10: ...roller A Lower the upper Canopy from ceiling to ensure minimum 3 mm clearance B Re tighten all screws on fan blades but never over tighten C Re tighten all screws in the hanging bracket or plate D Change the controller to the one supplied 3 Mechanical Noise A Allow at least for 8 hours settling in period 4 Fan Wobbles A Fan blades are not horizontal to ceiling B Blade screws are loose A Measure fr...

Page 11: ...rn the fan on and adjust the speed control usually high speed setting to the speed which creates to greatest wobble Turn the fan off select on blade place the balance clip on it Halfway between the blade holder and the blade up on the rear edge of the blade Turn the fan on watch to see of the wobble is improved or worse Then turn the fan off again and move the clip to another blade and test again ...

Page 12: ...hey have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Information requirements regarding the eco design Description Symbol Value Unit Maximum fan flow rate F 120 30 m3 min Fan power input P 42 4 W Service value SV 2 84 m3 min W Standby power consumption PSB 0 23 W Seasonal electric...

Reviews: