background image

QardioArm: Welcome to a smarter read on blood pressure! 

Your new QardioArm blood pressure monitor is a reliable medical device for taking measurements on 
the upper arm. This device was developed in collaboration with physicians and clinical tests were carried 
out prove its measurement accuracy. 

Every day, we at Qardio put our passion and effort into bringing you products of superior quality, design 
and technology that can change your life for the better. 

With its ease of use and accuracy, QardioArm is ideal for monitoring your blood pressure in your home, 
office or wherever is convenient for you. 

Please read through these instructions carefully so you understand all functions and safety information. 
We want you to be happy with your QardioArm. If you have any questions, problems or suggestions, 
please contact Qardio’s Customer Service on www.getqardio.com/support, or visit our website 
www.getqardio.com, for more information. 

Track your revolution with Qardio. 

Intended Use 

QardioArm is a fully automatic, non-invasive wireless blood pressure monitor. QardioArm is a blood 
pressure measurement system intended to measure the diastolic and systolic blood pressures and pulse 
rate of an adult individual. QardioArm utilizes an inflatable cuff that is wrapped around the upper arm. 
This device is not intended to be a diagnostic device. Contact your physician if hypertensive values are 
indicated. The cuff circumference is limited to 22cm-37cm (8.7in -14.6in). 

Important safety information 

Please read the User Guide carefully before using the QardioArm blood pressure monitor. In the case of 
pregnancy, arrhythmia and arteriosclerosis, consult your doctor before use. 

Package contents 

QardioArm blood pressure monitor  
Four AAA alkaline batteries, already pre-installed in the QardioArm. 
User Guide. 
Quick start leaflet. 

Requirements 

The QardioArm blood pressure monitor requires iOS 7.0 or later, and an iOS device with Bluetooth 4.0. 
These include: iPhone 4S, iPhone 5 or later, iPad 4th generation or later, iPad mini, iPod Touch 5th 
generation or later. 

In order to use your QardioArm blood pressure monitor, you have to install the Qardio app available for 
free on the Apple App Store, or on www.getqardio.com. 

Using QardioArm for the first time 

1.

 

Download the Qardio app: On your mobile phone or tablet go to 

www.getqardio.com and when prompted, download the app. Alternatively,go on 
the Apple App Store. The Qardio app is available for free. 

2.

 

Open the Qardio app on your phone or tablet. If requested, you should 

enable Bluetooth on your device, You can enable Bluetooth under the 

Settings

 

menu on your smartphone or tablet 

3.

 

Create a new user login, or login with your existing user name and 

password. Follow the on-screen instructions to register and set up your personal account. 

Summary of Contents for QardioArm A100

Page 1: ...QARDIO QardioArm A100 A Smarter Read on Blood Pressure User Guide Draft 0 9 drawings to be replaced not paginated and not formatted...

Page 2: ...is device is not intended to be a diagnostic device Contact your physician if hypertensive values are indicated The cuff circumference is limited to 22cm 37cm 8 7in 14 6in Important safety information...

Page 3: ...nder the cuff 2 Always ensure that the cuff fits correctly verifying the markings on the cuff You should fit the cuff closely but not too tight 3 Make sure that the cuff is positioned 2cm 0 8in above...

Page 4: ...re the measurement Always measure on the same arm normally left or as instructed by your doctor Ideally remove close fitting garments from the upper arm or ensure that rolling the sleeve up does not c...

Page 5: ...subject to wide fluctuations throughout the day depending on various potential factors including physical exertion and condition You should routinely take your measurements in quiet conditions when yo...

Page 6: ...mpartment 3 Put the batteries compartment hatch back in place pushing until it clicks in place 4 You will see a green light shining through the batteries compartment hatch Resetting the pairing In ord...

Page 7: ...pressure Do not take measurement immediately after bathing drinking alcohol smoking exercising or eating Do not use the QardioArm blood pressure monitor while operating a mechanical vehicle or in a mo...

Page 8: ...ed for a long period of time the batteries should be removed Store the device and the components in a clean dry and safe location Error messages and troubleshooting Problem Cause Remedy START button i...

Page 9: ...and correct if required 3 Replace the AAA alkaline cells Each measurement has significantly different results Under normal measuring circumstance the reading at home is different from that of the clin...

Page 10: ...user must deliver it to the able collecting centers for electric and electronic garbage or give back to the retailer when purchasing a new device Disposing of the product separately prevents possible...

Page 11: ...gnetic Compatibility FCC Rule Part 15 247 Cat DSS Bluetooth FCC Rule Part 15 247 Cat DTS BT4 0 EN ISO 10993 1 2009 Biological evaluation of medical devices Part 1 Evaluation and testing within a risk...

Page 12: ...s must follow the specific operating instructions for satisfying RF exposure compliance This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Indust...

Page 13: ...uld be used no closer to any part of the device including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter The device is inte...

Page 14: ...l Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors a...

Page 15: ...istered in the U S and other countries The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by Qardio Inc is under license Other trademarks...