Q-tran QOM-eLED+DMX Installation Instructions Manual Download Page 7

CSA REQUIREMENTS

● Suitable for Indoor and Outdoor use

● This power supply must be installed according to the National Electric Code and local codes and ordinances and in accordance with applicable installation 

    code by a person familiar with the construction and operation of the product and the hazards involved.

● Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.

● This power supply is to be installed in a location where it is not likely to be contacted by non-electricians.

● To avoid a hazard to children, account for all parts and destroy all packaging materials.

● 

DMX Shield wire must be grounded 

to Earth Ground at a single point external to Power Supply

QOM - eLED+DMX

CSA Label

© 2019, Q-Tran Inc.  155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777  -  [email protected]  -  www.q-tran.com 

6

Model

Input Voltage

 (V)

Frequency

Nominal Output

Voltage (VDC)

Nominal Output 

Wattage (W)

Input Current 

(A)

QOM-eLED-100

QOM-eLED-200

QOM-eLED-300

120

120

120

0.95 

1.90 

2.85 

50/60

50/60

50/60

24

24

24

100

200

300

QOM-eLED-60

QOM-eLED-120

QOM-eLED-180

120

120 

120 

0.60 

1.20 

1.80 

50/60

50/60

50/60

12

12

12

60

120

180

QOM-eLED

120V

INPUT VOLTAGE

OUTPUT VOLTAGE

24V

12V

CONTROL TYPE

DMX

0-10V

WD

AW

Model

Input Voltage

 (V)

Frequency

Nominal Output

Voltage (VDC)

Nominal Output 

Wattage (W)

Input Current 

(A)

QOM-eLED-100

QOM-eLED-200

QOM-eLED-300

120 / 277

120 / 277

120 / 277

0.95 / 0.40

1.90 / 0.80

2.85 / 1.20

50/60

50/60

50/60

24

24

24

100

200

300

QOM-eLED-60

QOM-eLED-120

QOM-eLED-180

120 / 277

120 / 277

120 / 277

0.60 / 0.29

1.20 / 0.58

1.80 / 0.87

50/60

50/60

50/60

12

12

12

60

120

180

QOM-eLED

120V - 277V

INPUT VOLTAGE

OUTPUT VOLTAGE

24V

12V

CONTROL TYPE

DMX

0-10V

WD

AW

WARNING:

 

      

RISK OF FIRE. IF INSTALLATION INVOLVES RUNNING WIRE THROUGH 

A BUILDING STRUCTURE, SPECIAL WIRING METHODS ARE NEEDED. 

CONSULT A QUALIFIED ELECTRICIAN

This product must be installed in accordance with the applicable 

installation code by a person familiar with the construction and 

operation of the product and the hazards involved.

CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D'INSTALLATION 

PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET 

SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS.

● Suitable For Indoor Or Outdoor Use

● Wall Mount Only

    

INSTALLATION MURALE SEULEMENT

● Suitable For Mounting Within 1.2m (4ft) Of The Ground

     PEUT ÊTRE INSTALLÉ À MOINS DE 1.2 M (4 PI) DU SOL

● Suitable For Use With Submersible Luminaires 

   

Or Submersible Pumps

 

Suitable For Wet Locations

    

CONVIENT AUX EMPLACEMENTS MOUILLÉ

 

● This Control Unit Has More Than One Power Supply Point

         

    Disconnect All Power Supplies Before Servicing 

    

COUPER L’ALIMENTATION AVEN L”ENTRETIEN

● For Supply Connections Use

 Wire Rated For At Least 60C.

● Keep Enclosure Cover Closed

● Read Installation Instructions Before Wiring

● Class 2

LOW VOLTAGE LIGHTING SYSTEM &

LED LANDSCAPE LIGHTING SYSTEM

Q-TRAN, INC.

 

MILFORD, CT U.S.A. 

(203) 367-8777 

WWW.Q-TRAN.COM

WARNING:

 

      

RISK OF FIRE. IF INSTALLATION INVOLVES RUNNING WIRE THROUGH 

A BUILDING STRUCTURE, SPECIAL WIRING METHODS ARE NEEDED. 

CONSULT A QUALIFIED ELECTRICIAN

This product must be installed in accordance with the applicable 

installation code by a person familiar with the construction and 

operation of the product and the hazards involved.

● Suitable For Indoor Or Outdoor Use

● Wall Mount Only

● Suitable For Mounting Within 1.2m (4ft) Of The Ground

● Suitable For Use With Submersible Luminaires 

   

Or Submersible Pumps

 

Suitable For Wet Locations

● This Control Unit Has More Than One Power Supply Point

         

    Disconnect All Power Supplies Before Servicing 

● For Supply Connections Use

 Wire Rated For At Least 60C.

● Keep Enclosure Cover Closed

● Read Installation Instructions Before Wiring

● Class 2

CLASS:

 

3425 - 15    3425 - 95

            3402 - 15    3402 - 95

LOW VOLTAGE LIGHTING SYSTEM &

LED LANDSCAPE LIGHTING SYSTEM

Q-TRAN, INC.

 

MILFORD, CT U.S.A. 

(203) 367-8777 

WWW.Q-TRAN.COM

CLASS:

 

3425 - 15    3425 - 95

            3402 - 15    3402 - 95

Summary of Contents for QOM-eLED+DMX

Page 1: ...203 367 8777 sales q tran com www q tran com Wear rubber shoes and work on a sturdy wooden or fiberglass ladder This power supply must be installed according to the National Electric Code and local codes and ordinances This power supply is to be installed and serviced only by an licensed electricians This power supply is to be installed so that it is not likely to be contacted by people To avoid a...

Page 2: ...VDC driver s and DMX decoder module s Driver has Class A sound rating DMX dimming down to 0 Class 2 Output 5 year warranty Low Voltage Lighting Systems CSA Class 3425 15 and Class 3425 95 CSA Standard C22 2 No 250 0 08 Luminaires ANSI UL Standard 2108 Low Voltage Lighting Systems CSA Std C22 2 No 250 13 14 Light Emitting Diode LED Equipment for Lighting Applications ANSI UL Standard 8750 Light Emi...

Page 3: ...Inc 155 Hill St Milford CT 06460 All rights reserved 203 367 8777 sales q tran com www q tran com 2 Distances are based on a 5 Voltage drop max This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved VDC 10 AWG 12 AWG 14 AWG 16 AWG 18 AWG 20 AWG 22 AWG 24 AWG 26 AWG 5 6mm2 3 ...

Page 4: ...n t have a controller yet how can I keep my lights on Change the Mode to COLR This allows to manually set a specific color to be on Adjust the Hue or WHIT to achieve the desired color This sets that specific color 3 My LEDs aren t coming out the right color They look like white has been added in Verify the Network Resolution NETW RES Default is 8 BT Check your DMX Programming Stick controllers com...

Page 5: ...P LOG LIN Dimming curve M DIM CURV 00 20 M display off SHOW M M M 99 99 0 255 Intensity Speed Show SPD INT M HUE M HUE White WHIT M M Intensity 0 255 INT display off 0 1535 0 255 M M M 1 512 Network resolution DMX address 8 BT 16 BT display off ADDR DMX RES NETW M Interpolation OFF VID COLR WHIT GLOW INTERPOL Other features Visual test run Locking the configuration Reset to factory defaults M disp...

Page 6: ...All rights reserved 203 367 8777 sales q tran com www q tran com A C LED DRIVER 2 120 277V B LED DRIVER 2 120 277V B LED DRIVER 2 120 277V B M M M QOM eLED DMX for exterior SECONDARY PRIMARY DMX Shield DMX DMX M iQ LED Blue Blue White White Green Green Red Red Black 24V W B G R 24V W B G R 24 W B G R 24 W B G R 24 NEU GND HOT DMX W B G R 24 iQ LED iQ LED iQ LED GND HOT NEU ...

Page 7: ...roduct must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D INSTALLATION PERTINENT PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET SON FONCTIONNEMENTAINSI QUE LES RISQUES INHÉRENTS Suitable For Indoor Or Outdoor Use Wall Mount Only INSTALLA...

Reviews: