INSTALATION
DESCRIPTION
Before servicing pump, disconnect electrical power source.
The QIS series closed-coupled pumps are made up of two sections, power or drive section and
the liquid end or pump section.
The pump is mounted to the frame of the drive motor by means of an adapter and is coupled to
the motor shaft. The impeller mounts on the stub shaft and is retained by one of the three methods.
The casing is fixed to the adapter with screws allowing to position the discharge outlet at 0°, 45°
and 90°. The internal, balanced mechanical seal (single or double) assures long seal life. The drive
motor is mounted on a frame having adjustable legs providing simple installation and leveling.
INSTALLATION GUIDELINES
UNPACKING EQUIPMENT
Check the contents and all wrapping when unpacking your equipment. Inspect all parts for
damage that may have occurred during shipping. Report any damage to the carrier.
LOCATION AND INSTALLATION
The pump unit should be located as near as possible to the liquid source and in a position where
the suction piping can be short and direct with a minimum number of elbows and fittings. It should
also be readily accessible for inspection and cleaning.
WARNING
Before servicing pump, disconnect electrical
power source, carefully relieve all pressure
and drain all fluids from pump and connected
piping.