MAX-FLO MY1-50 METAL & NON-METAL - Supreme Performance

Assembly, Installation & Operation Manual | www.qmax.com.my

3

READ ME FIRST - IMPORTANT INFORMATION

CHEMICAL REACTION DISCLAIMER

The user must exercise primary responsibility in selecting the product’s materials of 

construction, which are compatible with the fluid(s) that come(s) in contact with the product.   

The user may consult manufacturer and a manufacturer’s representative/distributor agent to  

seek a recommendation of the product’s material of construction that offers the optimum available 

chemical compatibility.
However neither manufacturer nor a gent shall be liable for product damage or failure, injuries, 

or any other damage or loss arising out of a reac-tion, interaction or any chemical effect that 

occurs between the materials of the product’s construction and fluids that come into contact 

with the product’s components.

SAFETY PRECAUTIONS

READ THIS MANUAL COMPLETELY BEFORE INSTALLING AND OPERATING THIS PUMP.   

FAILURE TO FOLLOW THESE PRE-CAUTIONS CAN RESULT IN SERIOUS INJURY OR 

DEATH.
WARNING:

 The pumps from this model are not intended to pump flammable or combustible 

materials (consult factory).

WARNING:

 Do not exceed maximum pressure stated on the pump serial number sticker. Pump 

exhaust may be loud and contain particles. Wear appropriate ear and eye protection. In the 

event of a diaphragm rupture material can be forced out of the air exhaust muffler. If product is 

hazardous or toxic pipe exhaust to appropriate safe area.

WARNING:

 Chemical Hazard. This pump is used for transferring many types of potentially 

dangerous chemicals. Always wear protective clothing, eye protection and follow standard safety 

procedures when handling corrosive or personally harmful materials. Proper procedures should 

be followed for draining and decontaminating the pump before disassembly and inspection of 

the pump. There may be small quantities of chemicals present during inspection.

WARNING: 

Before maintenance or repair, close the compressed air supply valve, bleed the 

pressure and disconnect air line from the pump. Discharge line may be pressurized. Any 

pressure must be relieved before service.

CAUTION

1.  To help avoid unnecessary damage to the pump, do not allow pump to run dry for long 

periods of time.

2.  Use only genuine Pump-Fit replacement parts to assure compatible pressure rating and 

longest service life. 

3. 

If pump is used with materials that tend to solidify or settle pump should be flushed after 

each use to prevent damage.

4.  nstall the pump in a vertical position or the pump may not prime properly.

5.  Re-torque all fasteners before operation. Creep of housing and gasket materials may cause 

fasteners to loosen. Re-torque all fasteners to insure against fluid or air leakage. 

6.  Unpack the pump and examine for any signs of shipping damage.   If damage is detected, 

save the packaging and notify the carrier immediately.

Summary of Contents for MAX-FLO MY1-50 METAL Series

Page 1: ...AIR OPERATED DOUBLE DIAPHRAGM PUMP Assembly Installation Operation Manual V1 0 2021 MY1 METAL NON METAL SERIES 50 MAX FLO...

Page 2: ...Pump Specifications 4 Explanation of Pump Nomenclature Technical Specifications Performance Curve Material Profiles 3 Recommended Installation Guide 6 4 Troubleshooting Guide 7 5 Dimension Drawing 9...

Page 3: ...t of a diaphragm rupture material can be forced out of the air exhaust muffler If product is hazardous or toxic pipe exhaust to appropriate safe area WARNING Chemical Hazard This pump is used for tran...

Page 4: ...kg 27 kg 48 kg PERFORMANCE CURVE 0 2 4 6 8 Pressure bar 0 28 56 84 112 10 140 Pressure psi 0 100 200 300 400 500 600 0 26 52 78 104 130 156 Q l min Q usgpm Measured with 20 C Water Air Consumption m3...

Page 5: ...and alkali not suitable solvent Can replace the EPDM EPR material 104 C 29 C Hytrel Good abrasion resistance used in most of the neutral fluid Can replace Bune N materials 104 C 29 C EPDM Abrasion re...

Page 6: ...R SUPPLY Connect the pump air inlet to an air supply with sufficient capacity and pressure to achieve desired performance A pressure regulating valve should be installed to insure air supply pressure...

Page 7: ...d Valve ball s not seating properly or sticking Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket Clean out around valve ball cage and valve seat area Rep...

Page 8: ...xcessive inlet pressure or air pressure Consult Chemical Resistance Chart for compatibility with products cleaners temperature limitations and lubrication Premature Diaphragm Failure Cavitation Enlarg...

Page 9: ...DRAWING NON METAL STAINLESS STEEL ALUMINUM Discharge 2 ANSI 150 Flange Air inlet 1 2 BSPT NPT Suction 2 ANSI 150 Flange Air outlet 3 4 BSPT NPT Discharge 2 BSPT NPT Air inlet 1 2 BSPT NPT Suction 2 BS...

Page 10: ...NTER BLOCK NON METAL ALUMINUM 5007 5009 501 1 501 2 501 3A 5006 5005 5004 5001 503 1 5002 5003 502 M02 M03 M04 M05 M06 M07 M08 M09 M10 M11 M12 M15 M14 M13 504 M16 M17 M19 M18 M01 5007 5009 501 1 501 2...

Page 11: ...Reversing pin O ring 2 M06 PM Piston 2 M07 VT Piston V ring 2 M08 AL Upper pilot valve 1 M09 VT Pilot valve O ring 1 M10 PM Bottom Pilot valve 1 M10 CM Air End Parts Part Number Description Quantity M...

Page 12: ...2 503 1 AL 503 1 KV 502 KV Fluid Chamber 2 502 PP 502 AL 502 SS 502 LL 504 AL Air Chamber 2 5001 TF Valve Ball 4 5001 ST 5001 HY 5001 BN 5001 EP 5001 GE 5001 VT 5001 PC 5001 SS 5001 LL 5001 CM Wet En...

Page 13: ...ENTER BLOCK MA2 MA3 MA4 MA5 MA6 MA7 MA8 MA9 MA11MA12 MA13 MA14 MA15 MA16 MA17 MA10 50 MA1 5007 501 01 501 2 501 3P 5009 5006 5005 5004 5001 503 1 5002 5003 502 NON METAL MA2 MA3 MA4 MA5 MA6 MA7 MA8 MA...

Page 14: ...s Part Number Description Quantity MA1 KV Air valve housing 1 MA2 SS Plug locking plate 2 MA3 PM Piston 1 MA4 VT Piston V Ring 2 MA5 VT Plug O Ring 2 MA6 KV Plug 2 MA7 PM Pilot valve 1 MA8 SS Valve pl...

Page 15: ...2 503 1 AL 503 1 KV 502 KV Fluid Chamber 2 502 PP 502 AL 502 SS 502 LL 5001 TF Valve Ball 4 5001 ST 5001 HY 5001 BN 5001 EP 5001 GE 5001 VT 5001 PC 5001 SS 5001 LL 5001 CM Wet End Parts Part Number De...