background image

 

 

2) Selecting Steady/Flashing Type   

Choose steady light or flashing light by using Steady/Flashing   

Selecting switch(1)- SELECTOR(1). 

L

 mode of the switch is for 

steady type and 

LF

 mode is for flashing type. 

 

 

 

3) Lens Assembling   

Assemble the product in reverse order of separating. 
 

 

Power lines and signal sound tone lines come out from the product. 

Please connect them correctly after referring to below instruction.

 

 

  Power line   
▪  Power line: UL1015-NO.18(0.75sq) 

  2c    400mm   

▪  In case of product using AC voltage, connect the line without   

Polarity(wire color). 

▪  In case of product using DC voltage, black line is negative(-). 

 

  Signal line 
▪  Signal line: UL1007-NO.22(0.3sq) 400mm   

 

 

 

 

▪  This product was manufactured with the structure for indoor use. 

Installing in any direction is okay for indoor use.

   

▪  Outdoor use is limited at a place where no water or very little 

water percolates. Mounting also should be done only on the 
vertical standing direction. 

▪  Mount at the place where exists low vibration, low impact, low 

moisture and low dust as long as possible.

 

▪  Please  make  a  hole  by  a  drill  where  you  need  to  attach  our 

product and refer to below picture for a hole size. (Make sure 
PCD from external view drawing.) 

▪  Fix the product by using nuts(M5-3EA) originally equipped on 

mounting bolt on bottom of the product. 

Indoor                                              Outdoor 

 

 

 

 

 

 

 

 

 

▪  Make sure end of any unused wires are insulated by tape. 

▪  If using voltage is seriously higher or lower than rated voltage, it 

can reduce the self-life of the product or can cause a problem on 

product operating. Make sure the using voltage does not exceed 

+/-5% of the rated voltage. 

▪  If lens or body of the product is contaminated by chemicals such   

as thinner, benzene, the product can be damaged, discolored or 

deformed. Please be careful.   

▪  Do not give strong impact to the product. It can be a reason of   

wire disconnection or short circuit. 

▪  Do not allow power to signal line. Must use contact point which 

has no power supply. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring Instruction 

 

Mounting 

 

Caution 

 