![Q-Light S100DL Operating Manual Download Page 2](http://html.mh-extra.com/html/q-light/s100dl/s100dl_operating-manual_764284002.webp)
2) Selecting Steady/Flashing Type
Choose steady light or flashing light by using Steady/Flashing
Selecting switch(1)- SELECTOR(1).
“
L
”
mode of the switch is for
steady type and
“
LF
”
mode is for flashing type.
3) Lens Assembling
Assemble the product in reverse order of separating.
Power lines and signal sound tone lines come out from the product.
Please connect them correctly after referring to below instruction.
▸
Power line
▪ Power line: UL1015-NO.18(0.75sq)
Ⅹ
2c 400mm
▪ In case of product using AC voltage, connect the line without
Polarity(wire color).
▪ In case of product using DC voltage, black line is negative(-).
▸
Signal line
▪ Signal line: UL1007-NO.22(0.3sq) 400mm
▪ This product was manufactured with the structure for indoor use.
Installing in any direction is okay for indoor use.
▪ Outdoor use is limited at a place where no water or very little
water percolates. Mounting also should be done only on the
vertical standing direction.
▪ Mount at the place where exists low vibration, low impact, low
moisture and low dust as long as possible.
▪ Please make a hole by a drill where you need to attach our
product and refer to below picture for a hole size. (Make sure
PCD from external view drawing.)
▪ Fix the product by using nuts(M5-3EA) originally equipped on
mounting bolt on bottom of the product.
Indoor Outdoor
▪ Make sure end of any unused wires are insulated by tape.
▪ If using voltage is seriously higher or lower than rated voltage, it
can reduce the self-life of the product or can cause a problem on
product operating. Make sure the using voltage does not exceed
+/-5% of the rated voltage.
▪ If lens or body of the product is contaminated by chemicals such
as thinner, benzene, the product can be damaged, discolored or
deformed. Please be careful.
▪ Do not give strong impact to the product. It can be a reason of
wire disconnection or short circuit.
▪ Do not allow power to signal line. Must use contact point which
has no power supply.
Wiring Instruction
Mounting
Caution