Signal Line : UL1007-NO.22(0.3sq) 400mm
▪ This product was manufactured with the structure for indoor use.
Installing in any direction is okay for indoor use.
▪ Outdoor use is limited at a place where no water or very little
water percolates. Mounting also should be done only with
vertical standing shape.
▪ Mount at the place where exists low vibration, low impact, low
moisture and low dust as long as possible.
▪ Refer to below information and drill necessary mounting holes on
profitable part of the product.
(Make sure PCD from external view drawing.)
▪ F
ix the product by using nuts(M5-3EA) originally equipped on
mounting bolt on bottom of the product.
Refer to following drawing and explanation for right operating.
S100D S125D
1) Lens Removal
Remove lens① by turning it counterclockwise and make sure
related parts on assembling board②.
2) Bulb Change
※ Warning ! Turn off Power
Must turn off power supply and change the bulb after at least
1 minute.
▪ Make sure the rated voltage and wattage of new bulb. If the
voltage of new bulb is higher than that of original bulb, the
self-life of product can be reduced and can cause damage on
lens and reflector. Therefore, please use same bulb as original
one which has same rated voltage and wattage or lower one.
▪ Bulb Removal : Press slightly the bulb downward and turn it
counterclockwise for removing.
▪ Bulb Fitting : Fit new bulb into the socket by pressing it
clockwise.
Bulb Removing Bulb Fitting
3) Lens Assmebling
Assemble the lens in reverse order of separating.
▪ If using voltage is seriously higher or lower than rated voltage, it
can reduce the self-life of the product or can cause a problem
on product operating. Make sure the using voltage does not
/- 5% of the rated voltage.
▪ If lens or body of the product is contaminated by chemicals such
as thinner, benzene, the product can be damaged, discolored
or deformed. Please be careful.