4
5
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO XL-G11.X / BFG – Q CELLS
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO XL-G11.X / BFG – Q CELLS
Validity
These instructions are only valid for crystalline solar modules from
the company Q CELLS as specified at chapter „2.1 Technical
Specifications“. Q CELLS assumes no liability for damage resulting
from failure to observe these instructions.
Ä
Please observe the wiring and dimensioning of the system.
Ä
The installer of the system is responsible for compliance with all
necessary safety regulations during set-up and installation.
Q CELLS assumes no liability on the basis of these instructions.
Q CELLS is only liable in the context of contractual agreements
or in the context of accepted guarantees. Q CELLS accepts no
other responsibility for the functionality and safety of the modules.
Ä
Please observe the instructions for any other system compo-
nents that may be part of the complete solar power system.
It may be necessary to carry out a structural analysis for the
entire project.
Additional information for the Operator
Ä
Please keep this manual for the entire life of the solar power
system.
Ä
Please contact your system supplier for information concerning
the formal requirements for solar power systems.
Ä
Please be sure to contact the relevant local authorities and
energy providers regarding regulations and permit requirements
prior to installation of the solar power system.
Other applicable documents
In addition to this Manual following technical information are
relevant:
DOCUMENT TYPE
Product data sheet
Packaging and transport information
1 INTRODUCTION
2 PLANNING
2.1 TECHNICAL SPECIFICATIONS
For additional information see the relevant datasheet of the module provided at www.q-cells.com.
PRODUCT LINE
Q.PEAK DUO XL-G11.3 / BFG
Type
Q.ANTUM DUO Z
Length
2416 mm
Width
1134 mm
Frame height
35 mm
Area
2.74 m²
Weight
34.4 kg
Max. system voltage V
SYS
1500 V (IEC) / 1500 V (UL)
Max. reverse current
25 A
Permissible
temperature range
–40 °C to +85 °C (–40 °F to +185 °F)
Junction box
protection class
≥ IP67 with bypass diode
Connector protection class
IP67 or IP68
Fire rating
C / TYPE 29 (New Type is similar to Type 3 but with metallic frame)
Max. test load Push / Pull
1
5,400 Pa / 2,400 Pa
Max. design load Push / Pull
1
3,600 Pa / 1,600 Pa
Middle rail
No
Certificates
Quality Controlled PV by TÜV Rheinland; CE-compliant; IEC 61215:2016; IEC 61730:2016; PV
module classification: Class II; QCPV Certification ongoing.
1
Test and design load in accordance with IEC 61215:2016, depending on mounting options (see section „2.3 Mounting Options“)
Fig. 1:
External dimensions (in mm) and components
for Q.PEAK DUO XL-G11.3 / BFG
1134 mm
35 mm
1092 mm
AU/
EN
Label
4 × Grounding holes,
Ø 4.5 mm
DETAIL A
16 mm
8.5 mm
21
mm
DETAIL B
10 mm
7 mm
22
mm
1090 mm
1400 mm
2416 mm
400 mm
790 mm
4 × Mounting slots (DETAIL A)
8 × Mounting slots system Tracker (DETAIL B)
4 × Drainage holes
(2.8 × 6 mm)
Frame
4 × Drainage holes
3 × 6 mm
≥ 750
mm
≥ 350
mm
508 mm