GENERAL SPECIFICATIONS

 

6

 

 

 

 

 

 

NOTICE:

 

 

Available in multiple AC outlet types.

 

 

 

 

Country       Voltage/Frequency 

 

Country 

Voltage/Frequency 

 

 

Universal

 

 

 

 

 

 

Israel

 

 

 

220V, 50Hz

 

 

 

 

 

China

 

 

 

220V, 50Hz

 

 

 

 

 

Australia

 

 

 

240V, 50Hz

 

 

 

 

 

Japan

 

 

 

100V, 50Hz/60Hz

 

 

 

 

 

UK

 

 

 

230V, 50Hz

 

 

 

 

 

Philippines

 

 

 

220V, 60Hz

 

 

 

 

 

Germany

 

 

 

230V, 50Hz

 

 

 

 

 

Korea

 

 

 

220V, 50Hz

 

 

 

 

 

France

 

 

 

230V, 50Hz

 

 

 

 

 

US

 

 

 

120V, 60Hz

 

 

 

 

South 

Africa

 

 

 

220V, 50Hz

 

 

 

Summary of Contents for ECOX 3

Page 1: ...PORTABLE POWER STATION USER MANUAL ...

Page 2: ......

Page 3: ...N as soon as possible once you receive it The battery may be in sleep mode or lose power during long periods of transport and storage Plug the POWER STATION into the wall outlet for 10 minutes to reactivate the battery If the battery still not charged after 10 minutes please contact customer service team Note When turning on the AC Button the LCD Display may show Output Power watts being drawn bef...

Page 4: ...季 季 ᶆ季 季 季 ᶎ季 ᶐ季 ᶏ季 季 季 季 1 LCD Screen Display 4 USB TYPE C 60W 7 Flashlight 2 AC Outlet 5 DC Input 8 Handle 3 USB QC3 0 6 Cigarette Lighter Output 9 Protective Cover 10 Power ON OFF Button 11 Flashlight ON OFF Button 12 AC Output ON OFF Button ...

Page 5: ...s the Master Switch Press POWER ON OFF BUTTON to activate the AC BUTTONS 12 Flashlight ON OFF Button Press FLASHLIGHT BUTTON once to turn on the flashlight press it again to turn off the flashlight Press and hold the FLASHLIGHT BUTTON over 3 seconds to switch to the SOS mode 13 AC ON OFF Button Press AC Output ON OFF BUTTON to activate AC output port ...

Page 6: ...it begins to draw power Remaining Charging Time Real time display of remaining charging time in hours and minutes Input Power Real time display of Input Power in Watts Remaining Usage Time Real time display of remaining service time in hours and minutes Output Power Real time display of the total Output Power in Watts Cigarette Lighter Port USB A USB C and AC Low Voltage Warning Please recharge th...

Page 7: ...C Outlet 1x 300W 600W surge Cigarette Lighter Port 1x 12V 10A USB A Ports 2x 5V 9V 12V up to 3A total 36W Max USB C Port 1x 5V 9V 12V 15V 20V 3A 60W Max Flashlight SOS Mode 1x 1W ACCESSORIES AC Adapter NOTICES Car Charger Cable User Manual Check the input charge cable The charging process can work efficiently only the input charge cable meets the specification outlined in the GENERAL SPECIFICATION...

Page 8: ... types Country Voltage Frequency Country Voltage Frequency Universal Israel 220V 50Hz China 220V 50Hz Australia 240V 50Hz Japan 100V 50Hz 60Hz UK 230V 50Hz Philippines 220V 60Hz Germany 230V 50Hz Korea 220V 50Hz France 230V 50Hz US 120V 60Hz South Africa 220V 50Hz ...

Page 9: ...off the output s power when not in use PASS THROUGH CHARGING The advanced battery management system of the POWER STATION allows powering device via DC USB AC output s while it s charging OVERLOAD CONDITION If the overload condition occurs to the OUTPUT POWER STATION will automatically turn off the battery power The LCD still display values The DC Output will still be the same status as normal OPER...

Page 10: ...ini Fridge 40W Gopro 5 9Wh DJ Drone 89 2Wh Floodlight 4W Smartphone 10Wh Switch 16Wh Please power charge the appliances within the rated power of power station The Watts Watt Hours listed above are just for reference and not suitable for all cases Please check your appliance use manual for the actual power ...

Page 11: ...the storage time is more than one month Recharge the POWER STATION every 3 months to avoid possible damages from a full discharge Please store in a cool moderately humid room out of direct sunlight Refer to GENERAL SPECIFICATIONS section Leaving POWER STATION in a car or other confined space with extremely hot temperatures will overheat the battery resulting in a shortened lifespan and even fires ...

Page 12: ...esume the functions E8 USB Output Overload Protection Please charge power the devices within the rated power of USB and then press the ON OFF Button to resume the functions E4 E5 E6 E9 Output Overload Protection When E1 E7 E8 occurs E4 E5 E6 E9 will be displayed to more accurately identify the problem Please charge power the devices within the rated powers and then press the corresponding button t...

Page 13: ...r codes section Sudden interruption while using output The power used by the connected device s exceeds the rated power of the POWER STATION Check if the connected device s is suitable for the power station by reviewing the output specifications in the GENERALSPECIFICATIONS section Only plug in devices within the rated Watts If you need a POWER STATION with a larger capacity wh you can browse our ...

Page 14: ...ildren people with physical mental handicap s or people who lack of experience and knowledge along with the POWER STATION unless under the supervision or guidance of their guardians DO NOT attempt to repair the POWER STATION or AC adapter There is no user repairable component inside DO NOT operate the POWER STATION with wet hands DO NOT place the POWER STATION on its side or place upside down duri...

Page 15: ...misused abused modified accidentally damaged or used for any purpose not authorized in the company s current product datasheet or ii Any product purchased through an online auction house Please contact our customer service team for more information and to obtain warranty service STATEMENT All rights reserved All trademarks cited herein are the property of their respective owners The information co...

Page 16: ...14 Scan to follow us www pytesusa com 920 S Holgate St STE 107 Seattle WA 98134 206 407 4974 pytesusa pytesgroup com ...