Table 20 - Environmental
Operational
-10°C to +40°C, Certified
Storage
-20°C to +60°C
Humidity
75%
Table 21 - Dimensions
PCX S
297 x 250 x 82mm Weight: 4.8kg inc battery
PCX L
390 x 305 x 100mm Weight: 11.5kg inc battery
Printed Circuit Board
170 x 90 x 30mm
Table 22 - EN50131 Grading
PCX S
Grade 2
PCX L
Grade 3
Table 23 - ATS (Alarm Transmission System)
The below table specifies ATS (Alarm Transmission System) performance criteria in accordance with
the requirements of EN50136-1:2012 and EN50136-2.
Notification Equipment
Grade 2 Criteria
Option A
Option B
Option C
Option D
Remotely powered external sounder
2
Optional
Optional
Optional
Self-powered external sounder
Optional
1
Optional
Optional
Main Communication Path (ATS)
ATS 2
ATS 2
ATS 2
ATS 3
Second Communication Path (ATS)
Optional
Optional
ATS 1
Optional
GRADE 2 option A, B, C and D with DIGI-LAN (SP5) or DIGI-GSM (SP2) and DP1 (DIGI-LAN or DIGI-
GSM with DIGI-1200).
The use of the DIGI-GPRS (SP5) or DIGI-LAN (SP5) Option “Grade 3 Option A, B and D" are
supported.
Communication loom
The ATE low power outputs are programmed in the engineer function: Program Outputs > Endstation
PGMs
Colour
Description
Number
Purple
ATE Output 8: Mains Fail
0052
Light grey
ATE Output 10: Unused
0000
White
ATE Output 9: Battery Fault
0053
Black
ATE Output 7: Engineer Access
0059