Pyronix Matrix 6/816 Installation Manual Download Page 28

Matrix 6/816 Installation Manual 

 

 

Page 24 

RINS546-10 

2.10 Battery Monitor Board Wiring 

+B
ATI

N–

+ BAT OUT –

17V~

N

C

RT

+

-

J1 Header

LED

Reset

Button

17
V

~+

 B

A

T

 -

Header A

Header B

Header C

Header Settings

Header J1

= Normally Closed

= End of Line

= Single End of Line

Header A = Enable Cut Off

Header B = Enable / Disable 24Hr

Header C = Spare

LED Indications

Off = Low Battery

On = Good Battery

10 Second Slow Flash 

= Battery Test

No Mains Supply

 

NOTE  1:    If  the  zone  connection  is  used,  adjust  header  J1  to  the  relevant  zone  setting,  i.e., 

Normally Closed, End Of Line or Single End Of Line. The zone setting of the battery monitoring 

board must be the same as that of the control panel. 
NOTE 2: The RT input will initiate a remote test. 

Summary of Contents for Matrix 6/816

Page 1: ...MATRIX 6 816 Control Panel with Remote Keypads Software Version 1 34 INSTALLATION MANUAL RINS546 10...

Page 2: ......

Page 3: ...mally Closed Wiring South Africa 14 2 6 2 Normally Closed Wiring Other Countries 15 2 6 3 Single End of Line SEOL Resistor Wiring 16 2 6 4 Double End of Line DEOL Resistor Wiring 17 2 7 On Board Zone...

Page 4: ...Matrix 6 816 Installation Manual Page ii RINS546 10...

Page 5: ...hand tools ONLY Do NOT use power drivers to tighten screws 1 1 Plastic Case Assembly IMPORTANT To ensure the correct airflow always mount the unit vertically Secure the unit to a sturdy and stable sur...

Page 6: ...ss the system Apart from being affected by current magnitude voltage drops are also dependent upon the length of cable and the types of devices fitted NOTE It is the length of cable between panel and...

Page 7: ...RINS546 10 Page 3 Example 1 NOT ACCEPTABLE 50m 100m K KD K Keypad 1 1 KEN Keypad 3 1 KEN Keypad 4 1 KEN Keypad 2 1 KEN Example 2 AUX K KD AUX K Keypad 1 1 KEN Keypad 3 1 KEN 50m 100m ACCEPTABLE SOLUTI...

Page 8: ...PAD FUSE RS 232 NVM RESET 1 4 1 Power Up Delay Upon power up the panel starts a 90 second delay The primary function of this delay is to give detectors time to settle before the panel is fully operati...

Page 9: ...put K K RKP supply output Protected by a 1 Amp KEYPAD FUSE KD RKP data bus NC1 PGM1 relay output Normally closed contact 1 PGM1 relay output Common contact NO1 PGM1 relay output Normally open contact...

Page 10: ...utput PGM7 NC1 PGM1 relay output Normally closed contact 1 PGM1 relay output Common contact NO1 PGM1 relay output Normally open contact PGM2 PGM2 transistor output PGM3 PGM3 transistor output PGM4 PGM...

Page 11: ...17V To mains 230V 17V Battery 12V To analogue telephone network Telephone terminals cross point TIP RING T 1 R 1 To other telephone equipment 2 3 2 Matrix 816 Transformer V V 230 17 To mains V 230 17...

Page 12: ...6 816 Installation Manual Page 8 RINS546 10 2 4 Tamper Switch Wiring 2 4 1 Matrix 6 Tamper switch connects to zone programmed as Tamper 2 4 2 Matrix 816 Tamper switch connects to zone programmed as T...

Page 13: ...Matrix 6 816 Installation Manual RINS546 10 Page 9 2 5 Keypad Wiring 2 5 1 Matrix 6 Without Tamper Multiple RKP connection to the panel RKP No1 RKP No RKP No RKP No RKP No...

Page 14: ...RINS546 10 With Tamper South Africa Multiple RKP connection to the panel RKP No 1 Tamper outputs of RKP KT KTR RKP No 1 RKP No 2 RKP No 3 RKP No 4 For tamper loop use zone programmed as Tamper For ta...

Page 15: ...Matrix 6 816 Installation Manual RINS546 10 Page 11 With Tamper Other Countries Multiple RKP connection to the panel RKP No1 Tamper outputs of RKP KT KTR RKP No RKP No RKP No RKP No...

Page 16: ...Matrix 6 816 Installation Manual Page 12 RINS546 10 2 5 2 Matrix 816 Without Tamper Multiple RKP connection to the panel RKP No 1 RKP No 1 RKP No 2 RKP No 3 RKP No 4...

Page 17: ...Matrix 6 816 Installation Manual RINS546 10 Page 13 With Tamper Multiple RKP connection to the panel RKP No 1 Tamper outputs of RKP KT KTR RKP No 1 RKP No 2 RKP No 3 RKP No 4...

Page 18: ...Zone Wiring 2 6 1 Normally Closed Wiring South Africa Matrix 6 Zone 1 Zone 2 Zone 5 PIR Detector Magnetic Contact PIR Detector For tamper loop use spare zone programmed as Tamper Matrix 816 Zone 2 Zo...

Page 19: ...ion Manual RINS546 10 Page 15 2 6 2 Normally Closed Wiring Other Countries Matrix 6 Zone 1 Zone 2 Zone 5 PIR Detector Magnetic Contact PIR Detector Matrix 816 Zone 2 Zone 7 PIR Detector PIR Detector Z...

Page 20: ...6 3 Single End of Line SEOL Resistor Wiring NOTE Any unused zones should be linked out using a 4k7 resistor Matrix 6 4K7 4K7 4K7 Zone 1 Zone 2 Zone 6 PIR Detector Magnetic Contact PIR Detector Matrix...

Page 21: ...e End of Line DEOL Resistor Wiring NOTE Any unused zones should be linked out using a 4k7 resistor Matrix 6 4K7 4 7 4K7 4 7 4K7 4 7 Zone 1 Zone 2 Zone 6 PIR Detector Magnetic Contact PIR Detector Matr...

Page 22: ...put COM Common input for zones 0V Z12 Zone 12 input Z13 Zone 13 input COM Common input for zones 0V Z14 Zone 14 input AUX Auxiliary supply output for detectors Protected by a 1 Amp AUX FUSE Z15 Zone 1...

Page 23: ...speaking into the on board microphone Release the PLAY RECORD key after the message is finished End of recording will be indicated as The maximum length of one message is 8 seconds 3 PLAYING A VOICE M...

Page 24: ...Matrix 6 Buzzer LED Any Siren Wiring Siren V 12 Strobe lamp V 12 LED 1 2 9 2 Matrix 816 Monitored Siren and Buzzer LED Siren V 12 Buzzer V 12 LED 1 NOTE If a monitored siren is not to be used either...

Page 25: ...nti Surge High Power Siren 15W 30W NOTE When a high power siren is to be connected to the Matrix the PGM1 C1 NO1 output should be used This output uses a relay to switch up to a maximum 3A dc current...

Page 26: ...ined sounder BELLE Transistor output PGM 2 PGM 3 and PGM 4 PGM 10 4 7 Relay output PGM 1 1 NO1 NC1 PGM output stage diagram Contacts position when output is off relay coil is de energized NOTE PGM1 mu...

Page 27: ...nder BELLE Transistor output PGM 2 PGM 3 and PGM 4 PGM 10 4 7 Relay output PGM 1 1 NO1 NC1 PGM output stage diagram Contacts position when output is off relay coil is de energized NOTE PGM1 must be pr...

Page 28: ...Header A Enable Cut Off Header B Enable Disable 24Hr Header C Spare LED Indications Off Low Battery On Good Battery 10 Second Slow Flash Battery Test No Mains Supply NOTE 1 If the zone connection is u...

Page 29: ...4 7 4K7 4 Wire Fire Detector 4 Wire Fire Detector 4 Wire Fire Detector 4 Wire Fire Detector 4 Wire Fire Detector 4 Wire Fire Detector The last in the zone loop or the only one in the zone The first in...

Page 30: ...st in the zone loop The second in the zone loop The last in the zone loop or the only one in the zone The first in the zone loop The second in the zone loop 4 7 4K7 4 7 4 7 Normally Closed Zone DEOL Z...

Page 31: ...re Fire Detector 4 Wire Fire Detector 4 Wire Fire Detector 4 Wire Fire Detector 4 Wire Fire Detector 4 Wire Fire Detector The last in the zone loop or the only one in the zone The first in the zone lo...

Page 32: ...st in the zone loop The second in the zone loop The last in the zone loop or the only one in the zone The first in the zone loop The second in the zone loop 4 7 4K7 4 7 4 7 Normally Closed Zone DEOL Z...

Page 33: ...o select A B C or D arm modes Directional buttons To scroll through the display Arm button To change arm modes and on off options in User and Engineer functions Fire button To activate a fire alarm Me...

Page 34: ...ms Tamper Illuminated Indicates a tamper condition used in log display Blinking Indicates a tamper condition in FTA mode Extinguished No tamper alarm active P A Illuminated Indicates a PA alarm condit...

Page 35: ...ON PGM3 Transistor Open Collector 200mA Matrix 6 PCB alone 60mA PGM4 Transistor Open Collector 500mA Remote keypad MX ICON 50mA Remote keypad MX LED 60mA DIGITAL COMMUNICATOR BATTERY Digital communica...

Page 36: ...ctor 200mA On board expander 1mA PGM6 Transistor Open Collector 200mA BATTERY Siren Transistor Open Collector 500mA Type Lead Acid rechargeable DIGITAL COMMUNICATOR Battery Charge commencing min 5 5V...

Page 37: ...m current B Maximum alarmed total system current Swedish Requirements Required capacity 12 x A Where A Maximum non alarmed total system current Non alarmed condition 11 hrs 45mins 11 75Hrs Control pan...

Page 38: ...mount the unit vertically with the unit having a clear space on all sides It must not be covered by clothes furnishings boxes etc It must not be mounted close to or above heat radiating sources 10 On...

Page 39: ......

Page 40: ...6 30 PM Monday to Friday Email customer support pyronix com Website www pyronix com WARRANTY This product is sold subject to our standard warranty conditions and is warranted against defects in workm...

Reviews: