EQ E / 15

EQ E / 15

EQ 10

EQ 10

15m
(50ft)

2m
(6.6ft)

PCB layput

NORMAL

ALARM

WARRANTY

This product is sold subject to our standard warranty 

conditions and is warranted against defects in workmanship 

for a period of two years. 

In the interest of continuing improvement  of quality, 

customer care and design, Pyronix Ltd reserve the right to 

amend specifications without giving prior notice

The following note applies only to FCC models -

This device complies with part 15 of the FCC rules.

Operation is subject to the following two conditions:

1. This device may not cause harmful interference and 2. 

This device must accept any interference received, including 

interference which may cause undesirable operation.

 

PYRO 

SENSOR

Pulse
count

select

LEDS

RELAY

TEST LINK

TEST LINK   (IMPORTANT)
 

The default for this link, “LED ON” is Test Mode
with all indication enabled. Following 
commissioning the link should be changed to 
“LED OFF” To place the detector into 
operational mode.

MICROWAVE

ADJUSTMENT

MICROWAVE

D2

D4

    and remove the PCB.   

    (Do not touch Pyro sensor       )

2

. Choose suitable wall fixing holes.

3

. Mark wall for fixing positions (Do not route wires near mains 

    cabling,  avoid vibrating surfaces, and only use solid wall).

4

. Drill fixing holes. 

5

. Fix case to wall.

6

. Replace PCB (Do not touch Pyro sensor       ).

8. 

Refit lid to case and fasten.

 

  

7. 

Rotate microwave adjustment to select the required range

    and if required adjust the PIR range as illustrated in 

 

  

POTENTIAL FALSE ALARM HAZARDS

1

. Direct sun light on detector may cause a PIR to activate.

Final Steps -

1. Apply power and wait 2 to 3 minutes for the detector to stabilise
2. Replace cover and walk test the detector to verify the sensitivity and
check that alarms are indicated at the control panel.
3. The three LEDs are colour coded as follows-

PIR detection = Green
Microwave detection = Orange 
Alarm = Red

4. If LEDs are to be disabled remove the test link header.
It is recommended that the LEDs are disabled after installation to prevent
potential intruders from walk testing the system.     
 

2

. False Alarms may be caused by pets and animals.

3

. Do not mount detectors near heaters.

4

. Open windows may induce false alarms caused by draughts and 

    moving objects .

DIAGRAMS

D4

D2

D3

A2

B4

D4

B1

A1

A2

B1

B2

B3

C1

D1

D2

D3

D4

E1

E2

E3

T T

T T

Use 5.0mm
drill bit.

B4

B2

B2

E3

E2

PYRONIX                                                            

TAMP
24HR

ZONE
ZONAS
ZONES

4

.7

R

E1

9 - 16Vdc
25mA
@12Vdc

12V
50mA

 60V
50mA

Control 
Panel

DETECTOR

INSTALLATION

1

. Remove case lid by unscrewing fixing screw       , 

NORMAL

ALARM

GB

B4

B1

Drill fixing
holes.

Mark wall for fixing
positions.

Wall fixing knockouts

Mounting holes

C1

62mm (2.44”)

3mm
(0.12")

42mm (1.56”)

1

2

4

m

m

(4

.8

8

)

Kg

= 225g (7.94 oz) without bracket

B3

Cable entry knockouts 

Replace Printed 
circuit board.

SPECIFICATIONS (QUICK REFERENCE)

Model:                        Equinox 10 - 15 and E                           

Colour:                        White                                                       

Casing:                       3mm  ABS, 0.4 mm HDPE in lens area                          

Detection method:      

PIR

 = Dual element Pyroelectric

                                   

Microwave doppler shift sensor =

 

                                   FET oscillator with twin patch antennas   
                                         
        

Detection Zones:        Lens 2, 54 zone edges           

Detection speed:         0.3 - 3m / s            

Operating  Voltage:     9 to 16 volts DC (12V nominal)                 

Quiescent Current:      25 mA at 12V                       

 Alarm       Current:      Alarm LEDS enabled = 45mA at 12V                       

 Alarm       Current:      Alarm LEDS Disabled = 15mA at 12V                       

Mounting Height:        1.8 to 2.4m (6 to 8 ft)                     

Tamper Switch:           Normally closed voltage free contacts                            

Storage Temp:            - 40  c to 60  c    14  f to 140  f                 

Operating Temp:         -30  c to 60  c    14  f to 140  f                        

Emissions:                  EN55022 class B                                                                   

Immunity:                    To new European standard EN50130-4                       

.

15M
50FT

LED On

LED On

LED On

LED On

LED On

LED On

O

R

N

G

E

A

O

R

N

G

E

A

O

N

G

E

R

A

O

N

G

E

R

A

R

G

O
AN
E

R

G

O
AN
E

E

R

DE

R

D

R

ED

R

ED

R

ED

R

ED

G

R
N

EE

G

R
N

EE

E

G

R

E

NE

G

R

E

N

G

R

E

NE

G

R

E

NE

LED Off

LED Off

LED Off

LED Off

LED Off

LED Off

PC 1

PC 1

PC 1

PC 1

PC 1

PC 1

PC 2

PC 2

PC 2

PC 2

PC 2

PC 2

- 12V +

- 12V +

C

C

N  

N  

T

T

T

T

- 12V +

- 12V +

C

C

N  

N  

T

T

T

T

- 12V +

- 12V +

C

C

N  

N  

T

T

T

T

Microwave 
Range Adjustment

Microwave 
Range Adjustment

Microwave 
Range Adjustment

Microwave 
Range Adjustment

Microwave 
Range Adjustment

Microwave 
Range Adjustment

+

+

+

-

-

-

Horizontal coverage pattern
PIR range adjustment
Wall fixing knockouts

Mounting holes

Cable entry knockouts

Case lid screw fitting

Measurements and weight
Analog pulse count options

PCB Layout
Microwave range adjustment          Pyro sensor

Wiring to control panel

Tamper operation

Relay contacts

Normal = Cover closed
Alarm = Cover open

 

Normal = No movement
Alarm = Cover open

  

EQUINOX 10/15 

& EQUINOX E

EQUINOX 10/15 

& EQUINOX E

15m
(50ft)

15m
(50ft)

PIR Range Adjustment

Analog Pulse Count Options 

 

Analogue pulse count measures the length of time an output
signal stays over the thresholds. If the amplifier output is over
the threshold for a given length of time then an alarm is raised.
To select 

PC2

 remove pulse count header from the link pins.  

 

Microwave adjustment

Maximum
Range

Minimum
Range

LED On

LED On

O

R

AN

G

E

O

R

AN

G

E

R

ED

R

ED

G

R

EE

N

G

R

EE

N

LED Off

LED Off

PC 1

PC 1

PC 2

PC 2

- 12V +

- 12V +

C

C

N  

N  

T

T

T

T

Microwave 
Range Adjustment

Microwave 
Range Adjustment

+

-

LED On

LED On

N

G

E

O

R

AN

G

E

O

R

A

ED

R

ED

R

G

R

EE

N

G

R

EE

N

LED Off

LED Off

PC 1

PC 1

PC 2

PC 2

- 12V +

- 12V +

C

C

N  

N  

T

T

T

T

Microwave 
Range Adjustment

Microwave 
Range Adjustment

+

-

D3

R

A1

A2

RINS302-9

D1

Horizontal Coverage
at Maximum Range
Setting

This product is approved for use in the 

Residential, Commercial and Light Industrial Environment.

Pyronix Limited
Pyronix House
Braithwell Way
Hellaby, Rotherham
S66 8QY, ENGLAND

Customer Support: 
+44(0)845 6434 999 (local rate)
or +44(0)1709 535225 
Hours: Mon to Fri, 8:00am till 6:30pm
Email: [email protected]
Website: www.pyronix.com

VOLUMETRIC

90

o

54 ZONE EDGES
3 PLANES

LENS 2

 

10M

12M

14M

15M

4M

6M

8M

2M

5m

10m

5m

10m

15m

5m

10m

15m

 Minimum range

 Maximum range

15m

5m

10m

15m

5m

5m

10m

15m

Equinox E / 15

Equinox 10

Equinox E / 15

Equinox 10

LED On

LED On

R

G

E

O
AN

R

G

E

O
AN

R

ED

R

ED

EE

N

G

R

EE

N

G

R

LED Off

LED Off

PC 1

PC 1

PC 2

PC 2

- 12V +

- 12V +

C

C

N  

N  

T

T

T

T

Microwave 
Range Adjustment

Microwave 
Range Adjustment

+

-

0.3 - 3.0 m/s

1    2    3    

PC1

 

PC2

 

This product complies with TS50131-2-4. at security grade 2, 

environmental class 2.

UK = Suitable for use with systems installed to PD6662:2004 (AMD)

EXPORT = Suitable for use with systems installed to EN50131-1

R

0C03

Relay Output:                50mA, 60VDC / 42VAC (RMS)

Contact Resistance       <10Ohms

2

TS50131-2-4
EN50131-1
PD6662:2004

Security Grade 2