2m
(6.6ft)
2m
(6.6ft)
15m
(50ft)
2m
(6.6ft)
EQ E / 15
EQ E / 15
EQ 10
EQ 10
15m
(50ft)
2m
(6.6ft)
PCB layput
NORMAL
ALARM
WARRANTY
This product is sold subject to our standard warranty
conditions and is warranted against defects in workmanship
for a period of two years.
In the interest of continuing improvement of quality,
customer care and design, Pyronix Ltd reserve the right to
amend specifications without giving prior notice
The following note applies only to FCC models -
This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference and 2.
This device must accept any interference received, including
interference which may cause undesirable operation.
PYRO
SENSOR
Pulse
count
select
LEDS
RELAY
TEST LINK
TEST LINK (IMPORTANT)
The default for this link, “LED ON” is Test Mode
with all indication enabled. Following
commissioning the link should be changed to
“LED OFF” To place the detector into
operational mode.
MICROWAVE
ADJUSTMENT
MICROWAVE
D2
D4
and remove the PCB.
(Do not touch Pyro sensor )
2
. Choose suitable wall fixing holes.
3
. Mark wall for fixing positions (Do not route wires near mains
cabling, avoid vibrating surfaces, and only use solid wall).
4
. Drill fixing holes.
5
. Fix case to wall.
6
. Replace PCB (Do not touch Pyro sensor ).
8.
Refit lid to case and fasten.
7.
Rotate microwave adjustment to select the required range
and if required adjust the PIR range as illustrated in
POTENTIAL FALSE ALARM HAZARDS
1
. Direct sun light on detector may cause a PIR to activate.
Final Steps -
1. Apply power and wait 2 to 3 minutes for the detector to stabilise
2. Replace cover and walk test the detector to verify the sensitivity and
check that alarms are indicated at the control panel.
3. The three LEDs are colour coded as follows-
PIR detection = Green
Microwave detection = Orange
Alarm = Red
4. If LEDs are to be disabled remove the test link header.
It is recommended that the LEDs are disabled after installation to prevent
potential intruders from walk testing the system.
2
. False Alarms may be caused by pets and animals.
3
. Do not mount detectors near heaters.
4
. Open windows may induce false alarms caused by draughts and
moving objects .
DIAGRAMS
D4
D2
D3
A2
B4
D4
B1
A1
A2
B1
B2
B3
C1
D1
D2
D3
D4
E1
E2
E3
T T
T T
Use 5.0mm
drill bit.
B4
B2
B2
E3
E2
PYRONIX
TAMP
24HR
ZONE
ZONAS
ZONES
4
.7
R
E1
9 - 16Vdc
25mA
@12Vdc
12V
50mA
60V
50mA
Control
Panel
DETECTOR
INSTALLATION
1
. Remove case lid by unscrewing fixing screw ,
NORMAL
ALARM
GB
B4
B1
Drill fixing
holes.
Mark wall for fixing
positions.
Wall fixing knockouts
Mounting holes
C1
62mm (2.44”)
3mm
(0.12")
42mm (1.56”)
1
2
4
m
m
(4
.8
8
”
)
Kg
= 225g (7.94 oz) without bracket
B3
Cable entry knockouts
Replace Printed
circuit board.
SPECIFICATIONS (QUICK REFERENCE)
Model: Equinox 10 - 15 and E
Colour: White
Casing: 3mm ABS, 0.4 mm HDPE in lens area
Detection method:
PIR
= Dual element Pyroelectric
Microwave doppler shift sensor =
FET oscillator with twin patch antennas
Detection Zones: Lens 2, 54 zone edges
Detection speed: 0.3 - 3m / s
Operating Voltage: 9 to 16 volts DC (12V nominal)
Quiescent Current: 25 mA at 12V
Alarm Current: Alarm LEDS enabled = 45mA at 12V
Alarm Current: Alarm LEDS Disabled = 15mA at 12V
Mounting Height: 1.8 to 2.4m (6 to 8 ft)
Tamper Switch: Normally closed voltage free contacts
Storage Temp: - 40 c to 60 c 14 f to 140 f
Operating Temp: -30 c to 60 c 14 f to 140 f
Emissions: EN55022 class B
Immunity: To new European standard EN50130-4
.
15M
50FT
LED On
LED On
LED On
LED On
LED On
LED On
O
R
N
G
E
A
O
R
N
G
E
A
O
N
G
E
R
A
O
N
G
E
R
A
R
G
O
AN
E
R
G
O
AN
E
E
R
DE
R
D
R
ED
R
ED
R
ED
R
ED
G
R
N
EE
G
R
N
EE
E
G
R
E
NE
G
R
E
N
G
R
E
NE
G
R
E
NE
LED Off
LED Off
LED Off
LED Off
LED Off
LED Off
PC 1
PC 1
PC 1
PC 1
PC 1
PC 1
PC 2
PC 2
PC 2
PC 2
PC 2
PC 2
- 12V +
- 12V +
C
C
N
N
T
T
T
T
- 12V +
- 12V +
C
C
N
N
T
T
T
T
- 12V +
- 12V +
C
C
N
N
T
T
T
T
Microwave
Range Adjustment
Microwave
Range Adjustment
Microwave
Range Adjustment
Microwave
Range Adjustment
Microwave
Range Adjustment
Microwave
Range Adjustment
+
+
+
-
-
-
Horizontal coverage pattern
PIR range adjustment
Wall fixing knockouts
Mounting holes
Cable entry knockouts
Case lid screw fitting
Measurements and weight
Analog pulse count options
PCB Layout
Microwave range adjustment Pyro sensor
Wiring to control panel
Tamper operation
Relay contacts
Normal = Cover closed
Alarm = Cover open
Normal = No movement
Alarm = Cover open
EQUINOX 10/15
& EQUINOX E
EQUINOX 10/15
& EQUINOX E
15m
(50ft)
15m
(50ft)
PIR Range Adjustment
Analog Pulse Count Options
Analogue pulse count measures the length of time an output
signal stays over the thresholds. If the amplifier output is over
the threshold for a given length of time then an alarm is raised.
To select
PC2
remove pulse count header from the link pins.
Microwave adjustment
Maximum
Range
Minimum
Range
LED On
LED On
O
R
AN
G
E
O
R
AN
G
E
R
ED
R
ED
G
R
EE
N
G
R
EE
N
LED Off
LED Off
PC 1
PC 1
PC 2
PC 2
- 12V +
- 12V +
C
C
N
N
T
T
T
T
Microwave
Range Adjustment
Microwave
Range Adjustment
+
-
LED On
LED On
N
G
E
O
R
AN
G
E
O
R
A
ED
R
ED
R
G
R
EE
N
G
R
EE
N
LED Off
LED Off
PC 1
PC 1
PC 2
PC 2
- 12V +
- 12V +
C
C
N
N
T
T
T
T
Microwave
Range Adjustment
Microwave
Range Adjustment
+
-
D3
R
A1
A2
RINS302-9
D1
Horizontal Coverage
at Maximum Range
Setting
This product is approved for use in the
Residential, Commercial and Light Industrial Environment.
Pyronix Limited
Pyronix House
Braithwell Way
Hellaby, Rotherham
S66 8QY, ENGLAND
Customer Support:
+44(0)845 6434 999 (local rate)
or +44(0)1709 535225
Hours: Mon to Fri, 8:00am till 6:30pm
Email: [email protected]
Website: www.pyronix.com
VOLUMETRIC
90
o
54 ZONE EDGES
3 PLANES
LENS 2
10M
12M
14M
15M
4M
6M
8M
2M
5m
10m
5m
10m
15m
5m
10m
15m
Minimum range
Maximum range
15m
5m
10m
15m
5m
5m
10m
15m
Equinox E / 15
Equinox 10
Equinox E / 15
Equinox 10
LED On
LED On
R
G
E
O
AN
R
G
E
O
AN
R
ED
R
ED
EE
N
G
R
EE
N
G
R
LED Off
LED Off
PC 1
PC 1
PC 2
PC 2
- 12V +
- 12V +
C
C
N
N
T
T
T
T
Microwave
Range Adjustment
Microwave
Range Adjustment
+
-
0.3 - 3.0 m/s
1 2 3
PC1
PC2
This product complies with TS50131-2-4. at security grade 2,
environmental class 2.
UK = Suitable for use with systems installed to PD6662:2004 (AMD)
EXPORT = Suitable for use with systems installed to EN50131-1
R
0C03
Relay Output: 50mA, 60VDC / 42VAC (RMS)
Contact Resistance <10Ohms
2
TS50131-2-4
EN50131-1
PD6662:2004
Security Grade 2
Environmental Class 2