Recalling the Event Log.
The event log can now be displayed at any time, when the Conqueror is unset. The
event log is displayed by pressing,
The 'Day' led will flash and event information from the latest alarm activation is
displayed. Pressing any key will then show the previous event information. When all
the four have been displayed the day led will stop flashing and another function can
be selected.
6.8
Omitting one or more zones
If one or more zones are triggered whilst in exit mode a low pitched error tone will be
produced. If any zones remain triggered at the end of the exit timer, the error tone will
continue. Key in the User code. The display will show the zone(s) which remained
triggered. Make a note of any triggered zones. Key in the User code which will clear
the display.
Check for any obvious reason for these zones to have been activated. This may
simply be due to a monitored door or window being left open or a pet being left in a
protected area. If the fault cannot be rectified it is possible to omit faulty zones, but this
should only be used as a last resort if the building is to be left unoccupied.
Example
Set panel (error tone will be heard).
Wait for the end of the exit timer.
Error tone is still being produced.
Key in the User code.
Triggered zones will be displayed.
Note triggered zones.
Key in User code to clear display then investigate fault(s) if possible.
Set panel again.
then:
Check the display if the zone(s) are not being triggered exit via normal
route.
or:
If displays shows zones are as still being triggered:
then enter:
now enter:
the number of the zone to be omitted (1 to 4)
then:
- Entry / Exit timer will start again.
then:
exit building by normal route.
6.9
Clearing the Event Log.
The User if allowed by the Engineer can clear the log. This is achieved by pressing,
6.10
Clearing the display after an activation
After an alarm condition enter the User code :
This unsets the panel.The LEDs will display any activated zones.
Enter User code again. This clears the display.
9
RINS 049 issue-1
6 USER FACILITIES
SHIFT
PA (PERSONAL ATTACK)
EASY-SET
UP ARROW
FIRE
DOWN ARROW
6.1
Full Setting the panel
Enter either of the following:
User Code
By using this method, maximum volume of the entry / exit tone will be heard.
or
By using this method, no sounds will be emitted except for an acknowledge
tone at the beginning and the end of the entry / exit time.
6.2
Part setting the panel
Part set 1 (eg downstairs only armed):
or
both will give a silent setting
Part set 2 (eg upstairs only armed):
Enter
or
both will give a silent setting
6.3
Unsetting the panel
The panel can be unset by entering the building via the entry / exit route and then
keying the user code.
6.4
Activating the Personal Attack Alarm (PA).
To activate the personal attack alarm enter
6.5
Activating the Fire Alarm.
To activate the Fire Alarm enter
6.6
Turning Chime On and Off
(Panel must be in day mode)
Enter
When the chime mode is selected a three note chime will be produced by the internal
sounder and any extension speakers when an Entry / Exit zone is activated. The same
key sequence can be used to turn off the chime facility.