background image

13

PYROMASTER

®

UVHB10 Vent-Free Heaters

20004232

LIMITED 2/20 YEAR WARRANTY

For CFM Harris Systems Decorative Gas Appliances

The CFM Harris Systems extends the warranties specified

in paragraphs A and B below with respect to its Decorative

Gas Appliances (the “Gas Appliance”), including the CFM

Harris Systems supplied accessories and components

referred to in those paragraphs, subject to the following

conditions and limitations:

   (1) These warranties are extended only to the Gas

Appliance installed in the continental United States,

including Alaska, and Canada; only if and so long as the

accordance with the installation and operating instructions

furnished therewith; and only if and so long as Gas

Appliance is not removed from its original installation.

   (2). These warranties are limited to only the component

parts manufactured and supplied by CFM Harris Systems

The use of components manufactured by others with the

Gas Appliance (except for a listed Type B venting system

as defined in the installation instructions) could create

serious safety hazard, may result in the denial of  certifica-

tion by recognized national safety agencies, and could be

in violation of local building codes.

   (3). The Gas Appliance must be operated at all times in

accordance with the operating instruction furnished

therewith.  The Gas Appliance is designed to burn either

natural or propane gas only.  Burning conventional

fireplace fuels such as wood, coal, or any other solid fuel

will cause damage to the Gas Appliance, will produce

excessive temperatures and will result in a fire hazard.

   (4).  These warranties are limited to repair, replacement

or furnishing a replacement for sale, as specified in

Paragraphs A and B, for a part found to CFM Harris

Systems’ satisfaction, after examination, to be defective in

materials or workmanship under normal conditions, use

and service.

   (5).  All obligations with respect to these warranties may

be fully discharged by CFM Harris Systems refunding the

wholesale price of a defective part.

   (6).  Except as otherwise expressly specified in Para-

graphs A and B. NONE OF THESE WARRANTIES

COVER, AND CFM HARRIS SYSTEMS SHALL NOT BE

RESPONSIBLE FOR, ANY CONSTRUCTION, INSTALLA-

TION, LABOR, TRANSPORTATION OR OTHER COSTS

OR EXPENSES ARISING FROM A DEFECTIVE PART,

ITS REPAIR OR REPLACEMENT OR OTHERWISE, NOR

SHALL CFM HARRIS SYSTEMS, INC. IN ANY EVENT BE

RESPONSIBLE FOR ANY INDIRECT, INCIDENTAL OR

CONSEQUENTIAL DAMAGES.  EXCEPT TO THE

EXTENT PROVIDED BY LAW, THERE ARE NO IMPLIED

WARRANTIES WITH RESPECT TO THE GAS APPLI-

ANCE, ITS COMPONENTS AND ACCESSORIES (IN-

CLUDING IMPLIED WARRANTIES OF MERCHANTABIL-

ITY OR FITNESS FOR A PARTICULAR PURPOSE), ALL

OF WHICH ARE HEREBY EXPRESSLY INCLUDED. IN

NO EVENT SHALL ANY IMPLIED WARRANTY PRE-

SCRIBED BY LAW (NOTWITHSTANDING THE FOREGO-

ING EXPRESS EXCLUSION) REMAIN IN EFFECT

AFTER EXPIRATIONS OF THE WARRANTIES SET

FORTH IN PARAGRAPHS A AND B.

   A. Gas Appliances, electrical and manual compo-

nents, glass panels, all sealants or adhesives and

optional accessories 

(exclusive of CFM Harris Systems

supplies decorative logs which are covered by a separate

warranty under paragraph B below):

   Within two years from the date of manufacture of the gas

appliance, CFM Harris Systems will repair, or replace (at

our option) a defective part without charge.

   B.  Cement or ceramic fiber log components:

Within two years from the date of manufacture of the gas

appliance, CFM Harris Systems will replace a defective

part without charge.  Within years three through twenty

from the date of manufacture of the gas appliance, CFM

Harris Systems will provide a replacement for a defective

part to the homeowner, but assumes no liability for

incurred labor cost.

   The foregoing  warranties gives you specific legal rights

and you may also have other rights which vary from state

to state.  Some states do not allow limitations on how long

an implied warranty may last, so the limitation specified

above on the duration of any implied warranty prescribed

by law may not apply to you.  Similarly, some states do not

permit the exclusion or limitation of incidental or conse-

quential damages, so the above exclusion of such dam-

ages may not apply to you.

   Since local building requirements may vary greatly through-

out the country, users of CFM Harris Systems products

should determine in advance whether there are any building

code restrictions on the use of a specified product.

CFM HARRIS SYSTEMS MAKES NO REPRESENTA-

TION OR WARRANTY REGARDING, AND SHALL NOT

BE RESPONSIBLE FOR, ANY BUILDING CODE COM-

PLIANCE.

Summary of Contents for UVHB10

Page 1: ...and service must be performed by a qualified installer service agency or the gas sup plier Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appli...

Page 2: ...ng bedding material etc 7 Control compartments burners and air passages in this heater should be kept clean and free of dust and lint Make sure that the gas valve and pilot light are turned off before...

Page 3: ...B10 Series Gas Appliance Corner Cabinet Fig 1 UVHB10 Series FPS1213N dimensions 26 36 26 45 2 7 3 2 26 30 10 12 45 7 7 4232c Fig 2 UVHB10 Series FPS1212NC and FPS1214W specifications and dimensions UV...

Page 4: ...10 0 w c Planning Planning the installation is an important first step it will save time and money later in the actual installation In planning the installation consider 1 Where the heater will be loc...

Page 5: ...ree 3 retaining screws that secure the hood to the unit Fig 3 Installation Hood FP1224 Outer Top FP1225 Fig 4 Remove outer top Fan Bracket Screws Radiant Shield Fan Burner Tube Shield Thermo disc Hex...

Page 6: ...ed it may be secured to the wall with nails or screws not provided When installed the heater must be electri cally connected and grounded in accor dance with local codes or in the absence of local cod...

Page 7: ...t flame appearance When Used as a Heating Appliance This appliance is equipped with a modulating valve which controls the main burner by a thermostat As the room temperature increases the flame will a...

Page 8: ...t follow these instruc tions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHA...

Page 9: ...lve Most of these components may require only an occa sional checkup and cleaning and some may require adjustment If repair is necessary it should be per formed by a qualified technician In order to p...

Page 10: ...refully tighten the fitting tight in valve C Weak pilot flame 1 The pilot flame must engulf the thermocouple Clean for maximum flame impingement on the thermocouple Fig 12 D Defective valve 1 Replace...

Page 11: ...7b Burner Tube LP 20004088 8a NG Pilot OXYPROTECTORNG 20001356 8b LP Pilot OXYPROTECTORLP 20001357 9 Piezo Ignitor Cable 24 20000101 10a Orifice Natural 20005382 10b Orifice LP 20000610 11a Valve Euro...

Page 12: ...ed system and as such must be operated only with PYROMASTER approved components If you use an unapproved component to make any modifications you may create a possible fire hazard and will void the PYR...

Page 13: ...Y CONSTRUCTION INSTALLA TION LABOR TRANSPORTATION OR OTHER COSTS OR EXPENSES ARISING FROM A DEFECTIVE PART ITS REPAIR OR REPLACEMENT OR OTHERWISE NOR SHALL CFM HARRIS SYSTEMS INC IN ANY EVENT BE RESPO...

Reviews: