background image

11

10005721

Pyromaster

 Electric Fireplace HEF33

Operating Instructions

1. Main On/Off Switch

The ON/OFF switch supplies power to all functions of
the fireplace. This is an illuminated switch that normally
lights up when in the ON or OFF position.

The control compartment is located behind the lower
louvre panel. To access the controls, simply flip down
the lower louvre panel. Refer to Fig. 9, below, to locate
the position of each control, .

During any service of this appliance, the
power to the unit must be turned off. It is
not acceptable to use the ON/OFF switch
to meet this requirement.

2. Heater Control

The Heater Control acts to turn the heater on and off as
well as setting the comfort level in the room.  Turning
the knob clockwise from the off position will place the
heater into operation.  The further the knob is rotated
clockwise, the higher the set point temperature.  Turn-
ing the knob counter-clockwise will lower the set point
temperature.  Turning it all the way counter-clockwise
will turn the heater function off.

Turn the flame speed control knob to increase or decrease
the flame speed as desired.

Control Panel

3. Flame Speed Control

FP1210

Fig. 9  HEF33 control panel.

GOLD

GOLD

GOLD

10005509

I'avant de I'appareil de chauffage.

soient a au moins 3 pieds (0,9m) de

tentures et autres textiles domestiques

veiller a ce que les cordons electriques,

AVERTISSEMENT: Risque d'incendie,

d'alimentation avant le service.

AVERTISSEMENT: Debrancher la source

des details sur le service.

Voir les instructions d'installation pour

heater.

least 3 feet (0.9m) from the front of the 

cords, draping, and other furnishings at

WARNING: Risk of fire, keep electrical 

Servicing.

WARNING: Disconnect Power Before

details.

See Installation Instructions for service

ON/OFF

LEARN

RED

3

2

1

5

4

4. Re-learn

This model fireplace with integral remote control has a
preprogrammed, matched-pair Receiver/Transmitter
already set with randomly-selected house codes. It is
highly unlikely that the fireplace code will ever need to
be re-learned. If the fireplace needs to re-learn
Receiver/Transmitter house codes, perform the
following steps:

1. Be sure there is power to the fireplace.

2. Be sure there is a good battery in the Transmitter

(hand-held remote).

3. Open the battery compartment of the remote.

4. Press and release the small button located in the

top left corner. This will randomly select a new
house code in the remote Transmitter.

5. Close the remote Transmitter battery compartment.

6. Press either the ON or OFF button on the remote

Transmitter, and the Learn button on the fireplace
at the same time. The fireplace is now ready to
accept commands from the remote Transmitter.

5. ON/OFF

The ON/OFF button on the fireplace (below the Learn
button) is to turn the fireplace ON and OFF when the
battery in remote Transmitter is weak, or to manually
operate the fireplace without the remote Transmitter.

NOTE: The device complies with Part 15 of the

FCC Rules. Operation is subject to the
following two conditions:

1. This device may not cause harmful

interference, and

2. This device must accept any interference

received, including interference that may
cause undesired operation.

Summary of Contents for HEF33

Page 1: ...N THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY Service must be performed by a qualified service ag...

Page 2: ...5 Framing and Finishing 5 Electrical Connection 6 Hard Direct Wire Connection 6 Removal of Logs 6 Installation of Trim Kit Assembly 6 Service Instructions Louvre Removal 7 Glass Frame Removal 7 Glass...

Page 3: ...indoor locations Never locate this appliance where it may fall into a bathtub or other water container 10 Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange...

Page 4: ...500 Watts Heater Rating 1300 Watts A D C B A E F ROD M M N G B ROW ROH O Framing Finishing A 33 838 mm B 28 733 mm C 16 416 mm D 31 787 mm E 22 430 mm F 11 292 mm G 3 76 mm M 36 914 mm N 51 1295 mm O...

Page 5: ...51 mm E 9 229 mm A B C D E V W X Y Z Fireplace Top Louvre Opening Top of Combus tion Chamber Bottom of Door Trim CFM164 Fig 2a Combustible mantel minimum installation J F G H I Mantel Leg Black Surrou...

Page 6: ...desired a qualified electrician may remove the cord connection and wire this unit directly to the household wiring See Page 14 Any electrical rewiring of this appliance must be done by a qualified el...

Page 7: ...am the glass 3 Do not use abrasive cleaners to clean the glass 4 This product uses tempered glass Replacement of the glass with gasket as supplied by the manufacturer should be done by a qualified ser...

Page 8: ...Removal NOTE Applicable only to units with bay window 1 Turn OFF electrical supply to unit 2 Let fireplace cool down if it has been operating 3 Remove top cover See Louvre Removal 4 Open lower louvre...

Page 9: ...Motor Variable Speed 12VDC 2 Switch ON OFF 3 Thermostat 4 Fan Heater 5 Light Socket with Wiring Assem 6 Light Bulb 60W 7 Breaker Circuit Manual Reset 8 Power cord 16 3 HPN with Terminal 9 Bushing Stra...

Page 10: ...ory installation Electrical Wiring Diagram without Integral Remote Control Wiring Color Code WH White BL Black RE Red Component Identification 1 Motor Variable Speed 12VDC 2 Switch ON OFF 3 Thermostat...

Page 11: ...ervice Voir les instructions d installation pour heater least 3 feet 0 9m from the front of the cords draping and other furnishings at WARNING Risk of fire keep electrical Servicing WARNING Disconnect...

Page 12: ...33 Replacement Parts Electric Fireplace 7 16 15 17 25 14 18 20 12 11 22 29 20 26 4 8 10 28 6 2 3 5 HEF33 13 27 305mm 12 216mm 8 1 2 DISTANCE BETWEEN TWO SOCKETS 216mm 8 1 2 DISTANCE BETWEEN TWO SOCKET...

Page 13: ...uvre Assembly 10000293 10000293 10000293 16 Hinge Access Door 52356 52356 52356 17 Trim Frame Window PB w 2 Magnets 55005 55005 18 Ceramic Refractory Kit AE2C00 AE2C00 AE2C00 19 Trim Kit Compete Not s...

Page 14: ...wire is connected to the circuit breaker The neutral wire is connected to the rocker switch and the green ground wire is attached to a ground stud on the rear panel of the control compartment 7 Using...

Page 15: ...BASE Pyromaster aux pr sentes nomm e la Soci t garantit votre nouveau foyer lectrique Pyromaster contre tous d fauts de fabrication et de mati res premi res pour une p riode d un an compter de la dat...