Operating Manual: PX-1C - Smoke Alarm Device with Radio Link
EN
65
EN
9.2 Connection test to the shared
radio group
You can check the correct connection of
a radio group to a shared radio group,
only on devices in a subgroup, as follows:
(1)
Press and hold testing/stop button
of any device of the subgroup for
approx. 60 seconds.
After approx. 1 second, the test
tone will sound.
After approx. 12 seconds, and
after 60 seconds, the test tone
sounds again.
(2)
Release the testing/stop button.
All devices in the shared radio
group emit a short test tone.
(3)
Repeat the process, if necessary, on
further subgroups.
5
Successful connection test of the
shared radio group.
10 Restoring factory
defaults
In the following situations, you must re-
store the factory settings:
•
Connection attempt was unsuc-
cessful and must be repeated
•
To remove the allocation of a device
to a radio group, e.g. defective device
Proceed as follows:
(1)
Pull out the activation button.
(2)
Press and hold the testing/stop
button for approx. 2 to 3 seconds
and then release.
(3)
Press the radio button using a split
pin until the signal LED starts to
flash yellow.
(4)
Then immediately release the radio
button.
5
The device is in its default state.