background image

 
 

Model 

5200 or 7200 - No Mag. Head ($1,$5 bills or 2 bills for foreign applications). 
5400 or 7400 - No Mag. Head ($1-$20 for US model and some foreign models) 
5600 or 7600 - Mag. Head ($1-$100 for US model, full note set for foreign model) 
 

Bezels 

5X00 or 7X00 - #0- Standard Bezel 
5X01 or 7X01 - #1- “Coinco” Style Bezel 
5X02 or 7X02 - #2- “VFM” Style Bezel 
 

Type 

S-  Stackerless

 

U- Upstacker 
D- Downstacker 
 

Cashbox 

N-  None (Stackerless only) 
2-   200 Bill Cassette 
5- 500 

Bill 

Cassette 

7-   700 Bill Cassette  
1-  1000 Bill Cassette 
A-   200 Plastic Bill Cassette 
C-   500 Plastic Bill Cassette 
D-   500 Plastic Lockable Cassette  

 

P.S./Comm. (Power Supply/Communication Options) 

1- 12 VDC (No harness supplied) 
2- Standard Cost 120 VAC supply (Ships with 9-pin AC harness) 
3- 120 VAC high level operational supply (Ships with 9-pin AC harness.) 
4- MDB Option (Ships with MDB harness)  
5- True RS-232 Option, 12VDC operation (Ships with DB-9/hard drive connector or USB harness)  
6- IGT ID022 (Ships with IGT ID022 Harness) 
7- Atronic Harness (Minor cabinet modification necessary) 
8- 12VDC Rear Exit Harness (Used in tight side to side mounting for 12VDC unit only) 
9- 24 VAC Version. (Ships with 9-pin 24 VAC harness)    
 

Country Code 

Follows ISO three (3) digit Country Code- Example USA = United States 
 

Serial Number Description 

Example Serial Number:     S/N  0838 00001 
In this example, the first two digits are the year of manufacture (20

08

). The week of manufacture is 

week 

38

 of 2008. The sequential production serial number is 

00001

 

Dimensional Drawings- Stackered and Stackerless Cassette Styles 

The stackered Apex bill acceptor can be ordered with either a 200, 500, 700 or a 1000 bill cassette. Locking 
cassettes are also available. The cassette has a cover that can easily be opened to retrieve the bills without 
removal of the cassette from the acceptor. For Dimensional Drawings, please visit our website at 

www.pyramidacceptors.com

 in the Bill Acceptors section. 

 

Accessories 

The following is a list of optional accessories available from Pyramid Technologies, Inc. See our website for 
additional items, photos, and information about accessories. 
 

Description 

 

 

 

 

Part Number 

 

PRO-1 Handheld Programmer  

 

PRO-1   

 

 

For Apex5000 Only 

The PRO-1 makes it easy to update Apex 5000 Bill Acceptors. (A PRO-2 programmer is currently under 
development to support both Apex 5000 and 7000 Models.) Simply pre-load the PRO-1 with the desired 

Summary of Contents for APEX 5000 Series

Page 1: ...APEX SERIES 5000 7000BILLACCEPTOR INSTALLATION OPERATION MANUAL Pyramid Technologies Inc 1718 North Quail Mesa Arizona 85205 USA 480 507 0088 FAX 480 507 1922 www pyramidacceptors com Rev V 06 28 11...

Page 2: ...and advanced diagnostics via PC Many interfaces available Pinouts compatible with other manufacturers bill acceptors Dual stage optical anti stringing Simple configuration and setup including DIP Swit...

Page 3: ...g for 12VDC unit only 9 24 VAC Version Ships with 9 pin 24 VAC harness Country Code Follows ISO three 3 digit Country Code Example USA United States Serial Number Description Example Serial Number S N...

Page 4: ...s harness is needed for USB communication The harness comes with a USB connector on 36 of cable as well as a hard drive connector on 36 of cable to obtain 12 VDC power for the note acceptor from the P...

Page 5: ...o install the acceptor disconnect all power to the machine Connect the interface cable from the machine to the acceptor On 120 VAC units connect the 9 pin power plug to the machine Install the green r...

Page 6: ...the card use a black felt tip marker and fill the selected block completely making sure no marks are outside the block Note As a service to our customers Pyramid Technologies Inc will configure each a...

Page 7: ...l hold the Configuration Card for a second or two then feed it back to you If the bezel lights are flashing rapidly the acceptor has read the Configuration Card correctly The configuration is now in p...

Page 8: ...will put the acceptor into a Configuration Mode and it will expect to have the Configuration Card inserted next If you have accidentally entered this mode cycle the acceptor power and start again Loo...

Page 9: ...ashes The cassette has been removed Replace the cassette 5 Flashes The acceptor is defective Replace the acceptor 6 Flashes The acceptor is not enabled Verify that the host has enabled the acceptor 10...

Page 10: ...Serial Pulse or Yellow 3 120 VAC Hot Enable 4 DC Power Ground Black 4 120 VAC Hot Power Not used for 24 VAC model 5 TXD for Mars 600 or TTL RS232 Green 5 No Connection 24 VAC hot for 24 VAC model 6 No...

Page 11: ...n 1 120 VAC Neutral Inhibit Green wire Connect to 120 VAC Neutral to disable acceptor If left floating may disable acceptor based on the state of the 120VAC Hot Enable line Note Low cost 120 VAC suppl...

Page 12: ...n collector output transistor on Pin 1 Brown wire on the 18 pin connector 5 12 VDC at 40 mA Max In addition the 120 VAC model 24 VAC model and 12 VDC model have an Out of Service output located on Pin...

Page 13: ...he Apex bill acceptor to the Host Message Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Hex V l 1 Credit 1 0 0 0 0 0 0 1 81H Not Used 1 0 0 0 0 0 1 0 82H 5 Credit 1 0 0 0 0 0 1 1 83H 10 Credit 1 0 0...

Page 14: ...se customer installation Order RS 232 Communication Harness P N 05AA0009 to have this ability if you use RS 232 If you use USB order USB Communication Harness P N 05AA0023 This RS 232 mode uses a thre...

Page 15: ...in our 12 VDC models as well as our 120 VAC and 24 VAC models Interface Operation The Inhibit line is used to enable the Apex bill acceptor Pull it low to enable the acceptor high to disable The Alar...

Page 16: ...he 18 pin connector Open collector normally high output Pulled low for 100 msec when this bill is recognized Open collector normally high output Pulled low for 100 msec when this bill is recognized Cr...

Page 17: ......