![Pynamite 11525 Manual Download Page 2](http://html1.mh-extra.com/html/pynamite/11525/11525_manual_1632256002.webp)
Page 2 of 7 10 gal # 11525
CONTENTS:
10 gallon System
Pressure Tester
Remote Control
Battery Charger
==================================================================================================
Before installation
Pynamite Mosquito Misting Systems are shipped with a charged battery, however if the system is not installed and
plugged in soon after receipt, the battery will discharge. Plug the system in prior to or during the installation to ensure
the battery is charged and the system is able to operate fully when installation is complete. Allow 6-8 hours to fully
charge a dead battery.
==================================================================================================
MISTING TIMES
Mist durations are preset for 60 seconds. For mosquito misting, set the timer to mist at dusk, dawn, and then an
additional mist around 10 pm. It will take a couple days to get control of your yard initially and sometimes after a big
rain and breeding cycle. Use the remote control to mist in between scheduled mists.
==================================================================================================
PROGRAMMING THE TIMER
Buttons on Timer
1. LED: To indicate ON/OFF status
2. CLOCK: To adjust current DAY and TIME
3. TIMER: To Review & Set Programs
4. DAY: To adjust Day of Week
5. HOUR: To adjust Hour
6. MIN: To adjust Minute
7. MANUAL: To select ON, AUTO or OFF
(see more on MANUAL button below)
8. P : Reset Timer’s Settings
NOTE: Press P button to reset Timer before programming
1.
Adjusting CLOCK
Press and hold CLOCK and then press DAY, HOUR, MIN, respectively to adjust clock of Timer to accurate DAY,
HOUR & MINUTE. To change to the 24-Hour Format where LCD screen indicates, 0:00-23:59, hold the CLOCK
button down for 3 seconds.
2.
Programming the Timer
A.
Press TIMER. LCD screen shows 1 --:-- .
B.
Press DAY to select any of the preset 15-combinations. Continuing to press DAY, the LCD alternates between the
15-combinations.
C.
Press HOUR, MIN respectively to set desired Hour and Minute for 1 0N.
D.
After finished setting 1 0N, Press TIMER again, 1 --:-- will appear on LCD screen to set 1 OFF.
E.
Press DAY to select the same Day combination as 1 ON.
NOTE: DAY-combinations chosen in each of ON/OFF program-period must be consistent
F.
Press HOUR, MIN respectively to set desired Hour and Minute for 1 OFF.
CAUTION: AN “OFF” SETTING OF 1 MINUTE LATER MUST BE PROGRAMMED FOR EVERY “ON”
SETTING. For example, if 8:00 is scheduled for ON, then 8:01 must be scheduled for OFF. IF THIS IS
NOT DONE, SCHEDULED MISTING CYCLES WILL NOT INITIATE AND REMOTE WILL NOT WORK. At any
time entire clock can be reset by pressing the grey button next to P .
If you should experience any difficulties, issues or problems while
assembling or operating your system, contact customer service at
[email protected] or 866-986-5586.
on
--
off
--