background image

 

RV12100

_

 

    

Master Instruments Pty Ltd 

 

2.3 System Wiring 

2.3.1. Parallel Connection: 

Before wiring the battery model, make sure all batteries are turned off. Follow the steps 
shown below for wiring, with all positive poles together and all negative poles together. 
Then press any battery’s Power button and the other batteries will turn on automatically. 

 

 

Please Note: 

1.  The number of Parallel connections is limited to 8 pieces 
2.  Ensure that the voltage difference between the batteries should not exceed 0.2V 

before connection. If batteries do exceed 0.2V difference then all batteries will 
require a full charge so they are an equal voltage. 

3.  Each set of the battery external cables should have the same wire diameter and 

length. This keeps the current flow of each battery consistent during operation. 

4.  When 2~8 batteries are connected in parallel, the charge-discharge current shall 

not exceed 0.5C of the total bank capacity. 

Summary of Contents for RV12100

Page 1: ...ly during the installation process Any confusion please contact Pylontech immediately for advice and clarification Table of Contents 1 Introduction 2 1 1 Product features 2 1 2 Product appearance 2 1...

Page 2: ...le configuration and high reliability Voltage platform 12V High C rate the output power reaches sustained 1C High safety lithium iron phosphate battery is safe and reliable High reliability interactiv...

Page 3: ...arine use 2 Product Parameters 2 1 Battery Module Technical parameters No Item Value 1 Nominal capacity 100 Ah 2 Nominal voltage 12 8Vdc 3 Voltage range 10 14 8 Vdc 4 Recommend charge voltage 10 14 4...

Page 4: ...lth will light up and 1 second later the battery output will be active Press the Power Button for 3 seconds to turn off the battery Turning the battery back on is locked out for 3 seconds Self check l...

Page 5: ...State Soc Status SOC Remark Run ALM SOC4 SOC3 SOC2 SOC1 Turn off All off Idle 0 25 All SOC Light is solid 26 50 51 75 76 100 Charge 0 25 The SOC top one is flashing others are solid 26 50 51 75 76 100...

Page 6: ...1 The number of Parallel connections is limited to 8 pieces 2 Ensure that the voltage difference between the batteries should not exceed 0 2V before connection If batteries do exceed 0 2V difference t...

Page 7: ...en the batteries should not exceed 0 2V before connection If batteries do exceed 0 2V difference then all batteries will require a full charge so they are an equal voltage 4 Connect all batteries in p...

Page 8: ...d heat Battery storage SOC 40 50 Long term storage before storage the SOC should be more than 80 and the battery should be periodically recharged every six months to the 80 SOC Our products come with...

Reviews: