14
KH-ES4850
Caution
Must keep pressing the “Lock Button” while pulling out the power plug.
Vous devez continuer à appuyer sur le « Bouton de verrouillage » tout en
retirant la fiche d'alimentation.
LED Status Indicators
Condition
RU
N
ALR
1
2
3
4
5
6
Power off
-
-
-
-
-
-
-
-
Power on
●
●
●
●
●
●
●
●
Idle/Normal
●
-
-
-
-
-
-
-
Charge
●
-
Show soc; highest LED flash
on: 0.5s; off 0.5s
Discharge
●
Show soc
Alarm
ALR:
●
; Other LEDs are same as above.
System
error/Protect
-
●
-
-
-
-
-
●
/
●
ON
●
flash, on: 0.3s; off: 3.7s
●
/
●
flash, on:0.5s; off: 1.5s
BMS basic function
Protection and alarm
Management and monitor
Charge/Discharge End
Cells Balance
Charge Over Voltage
Intelligent Charge Model
Discharge Under Voltage
Charge/Discharge Current Limit
Charge/Discharge Over Current
Capacity Retention Calculate
High/Low Temperature(cell/BMS)
Administrator Monitor
Short Circuit
Operation Record
Summary of Contents for KH-ES4850