background image

 

 

 
 

1

 / 

21

 

                                                                                                                                                                                                              16BISV0903 
 

 

 

 
 
 
 
 
 
 
 
 

 

Lithium-Ion Phosphate Battery   
Phantom-X1 Product Manual 

Information Version: 1.0

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pylon Technologies Co., Ltd. 

No. 73, Lane 887, ZuChongzhi Road, Zhangjiang Hi-Tech Park 

Pudong, Shanghai 201203, China Zip Code: 201203 

Tel: 021-51317697 

Fax:    021-51317698 

Email: 

[email protected]

 

Website: 

http://www.pylontech.com.cn

 

Summary of Contents for Phantom-X1

Page 1: ...oduct Manual Information Version 1 0 Pylon Technologies Co Ltd No 73 Lane 887 ZuChongzhi Road Zhangjiang Hi Tech Park Pudong Shanghai 201203 China Zip Code 201203 Tel 021 51317697 Fax 021 51317698 Email service pylontech com cn Website http www pylontech com cn ...

Page 2: ...onnecting 3 In Using 3 2 INTRODUCTION 5 2 1 features 5 2 2 Specifications 6 2 2 1 Battery System 6 Remark The parameter will be changed when the battery modules in different series 6 2 2 2 Battery Module 7 Battery Module Front Interface 8 2 2 3 Control Module internal power supply 8 Definition of RJ45 Port Pin 10 LED Indicators Instructions 10 3 INSTALLATION 12 3 1 Tools 12 3 2 Safety Gear 12 2 5A...

Page 3: ... Please ensured the electrical parameters of battery system are compatible to related equipment 7 Keep the battery away from water and fire In Using 1 If the battery system needs to be moved or repaired the power must be cut off and the battery is completely shutdown 2 It is prohibited to connect the battery with different type of battery 3 It is prohibited to put the batteries working with faulty...

Page 4: ...nths and the SOC should be no less than 80 3 Battery needs to be recharged within 12 hours after fully discharged 4 Do not expose cable outside 5 All the battery terminals must be disconnected for maintenance 6 Please contact the supplier within 24 hours if there is something abnormal 7 The warranty claims are excluded for direct or indirect damage due to items above ...

Page 5: ...s The whole module is non toxic non polluting and environmentally friendly Cathode material is made from LiFePO4 with safety performance and long cycle life Battery management system BMS has protection functions including over discharge over charge over current and high low temperature The system can automatically manage charge and discharge state and balance current and voltage of each cell Flexi...

Page 6: ...age Vdc 426 11 Battery System Charge Current Standard 10 12 Battery System Charge Current Normal 25 13 Battery System Charge Current Max 50 14 Battery System Discharge lower Voltage Vdc 366 15 Battery System Discharge Current Standard 10 16 Battery System Discharge Current Normal 25 17 Battery System Discharge Current Max 50 18 Efficiency 96 19 Depth of Discharge 80 10 90 20 Dimension W D H mm 600...

Page 7: ...Voltage Vdc 53 25 12 Battery System Charge Current Standard 10 13 Battery Module Charge Current Normal 25 14 Battery Module Charge Current Max 50 15 Battery Module Discharge lower Voltage Vdc 44 25 16 Battery System Discharge Current Standard 10 17 Battery Module Charge Current Normal 25 18 Battery Module Charge Current Max 50 19 Efficiency 96 20 Depth of Discharge 80 10 90 21 Dimension W D H mm 4...

Page 8: ...n between multiple serial battery modules and control module Power Terminals Power cable terminals there are two pair of terminals with same function one connect to equipment the other one paralleling to other battery module for capacity expanding For each single module each terminal can achieve charging and discharging function For power cables uses water proofed AMPHENOL connectors It must keep ...

Page 9: ...ry system Nether position is OFF means 0 Upper position is ON means 1 1st bit to 5th bit is for address and the 6th bit dial switch support a 120Ω resistance Power Output Switch To control the high voltage DC power ON OFF during the System Switch ON Normally it turns in ON position needn t turn it OFF CAN RS485 CAN Communication Terminal RJ45 port follow CAN protocol for communication between batt...

Page 10: ...y LED Indicators Instructions Battery Statues Protection Alarm Normal RUN ALM PRC Capacity SOC Descriptions Shut Down Off Off Off Off Off Off Off All off Sleep Normal Flash 1 Off Off Off Off Off Off Indicates Sleep Mode to save the power Standby Normal Flash 1 Off Off Off Off Off Off Indicates save power mode Alarm Off Light Off Off Off Off Off Indicates the battery is low Standby Normal Flash 1 O...

Page 11: ...Abnormal Protection Off Off Light Off Off Off Off Stop charging discharging PRC lighting Note The flashing instructions flash 1 0 25s light off 3 75 seconds flash 2 0 5s light 0 5s off flash 3 0 5s light 1 5s off External power supply Control Module External power supply Control Module has an Australia standard AC Power input socket and power switch It is applied with UPS system ...

Page 12: ...r tips with electrical tape 3 2 Safety Gear It is recommended to wear the following safety gear when dealing with the battery pack Insulated gloves Safety goggles Safety shoes 2 5Accessories The type and quantity of the accessories are subject to the battery packing list NOTE Power cable uses water proofed AMPHENOL connectors It must keep pressing this Lock Button during pulling out the power plug...

Page 13: ...ange 0 18m 4AWG 1 Orange 1 Black Surlok Terminal pcs 7 Battery Cascade Communication Cable 0 18m Black 0 18m 8 Core Super 5th Class Twisted pair Wire RJ45 pcs 7 Battery Cascade Communication Cable 1 5m Black 1 5m 8 Core Super 5th Class Twisted pair Wire RJ45 pcs 1 External Battery CAN Communication Cable direct Black 3 5m Super 5th Class Twisted pair Wire 2 RJ45 terminal pcs 1 ...

Page 14: ... is additional AC power cable AC Power Cable Australia Standard Black 1 5m 3 0 75mm2 Australia Standard pcs 1 Grounding The Phantom X1 modules is grounding based on metal direct touch between the module s surface and rack s surface So it needn t grounding cables at all If uses normal rack it can remove the paint at the corresponding place Or install a grounding cable to the grounding point of the ...

Page 15: ... at a constant level There is minimal dust and dirt in the area CAUTION If the ambient temperature is outside the operating range the battery pack stops operating to protect itself The optimal temperature range for the battery pack to operate is 0 C to 50 C Frequent exposure to harsh temperatures may deteriorate the performance and life of the battery pack Installation A Put battery modules into c...

Page 16: ... module and the battery modules into the cabinet Drive the screws to fasten each module on the rack Connect the cables between battery modules and the control module The cables installation sequence is as numbers in the right diagram ...

Page 17: ...l with the battery system 1 Switch battery system switch on All the control modules and the battery modules green LED light status and capacity as below will be on If all the LED light on as normal which means the battery system is good and working 2 Check the battery system s working status on control module 3 Turns the power output switch on ...

Page 18: ...e the battery module for service must charge discharge the replaced battery same similar voltage to the other in system battery modules Otherwise the system need long time to do the balance for this replaced battery module NOTE After installation do not forget to register online for full warranty www pylontech com cn service registration ...

Page 19: ...Module and the status LED of Battery Module is orange That s means some running condition is out of setting parameters range The battery system is not failure 4 If the system is turned on the status LED of Control Module is red it means the system is in protection mode or has failure If the status LED of Battery Module is also red in protection mode or has failure voltage current temperature prote...

Page 20: ...ention 2 Fire NO WATER Only dry powder fire extinguisher can be used if possible move the battery pack to a safe area before it catches fire 3 Wet Batteries If the battery pack is wet or submerged in water do not let people access it and then contact Pylontech or an authorized dealer for technical support 4 Damaged Batteries Damaged batteries are dangerous and must be handled with the utmost care ...

Page 21: ...21 16BISV0903 Pylon Technologies Co Ltd No 73 Lane 887 ZuChongzhi Road Zhangjiang Hi Tech Park Pudong Shanghai 201203 China T 86 21 51317697 F 86 21 51317698 Eservice pylontech com cn Wwww pylontech com cn ...