www.PyleUSA.com
6
www.PyleUSA.com
7
NOTE
The counting mode can be changed between Automatic and Manual.
Press the “AUTO” button, if the batch display shows “AUTO” the machine is in auto-
matic counting mode; If without the “AUTO” shown in the display, the machine is in
manual counting mode, under this manual mode, press the “RESET” button after
placing the bills to start counting.
2. Addition Function Counterfeit Detection
Addition function can be performed by pressing the “ADD” button (the ADD
indicator will appear). In this case, removing the counted bills from the stack will
not clear the quantity counted and shown on the counting display. The next bills
placed in the hopper will be counted and added to the preceding quantity. The
total amount of added bills will be shown on the counting screen. Press the “ADD”
button to close the function and clear the counting display.
3. Batch Function
•
The preset batch function can be performed by pressing the “BATCH” button
(the BATCH indicator will appear). By default, when pressing the “BATCH” button,
the batch function is turn on. The batch number can be set in amounts between
1and 999 by pressing “+” or “-” button. To clear this function, press the “BATCH”
button until the indicator is off.
•
Under the batch counting mode, once the hopper is loaded, the machine will
start counting and stopping when the counted quantity reaches the preset
batch one.
•
To repeat the batch counting operation under the same preset batch quantity,
just remove the counted bill from the stacker. The unit will batch the next group
of bills under the same settings.
•
If you wish to keep batching without removing the preset number, press the
“RESET” button.
•
If the counted number does not equal with the preset batch number, the
counter display will show the quantity with blinking number.
•
When counting with MG and/or UV detection on, the machine will stop
automatically when detecting counterfeit currency. This function can be resumed
by removing the dubious bill from the stacker and pressing “RESET” button.
6. Counterfeit Detection
UV (Ultraviolet) detection function <available for the model with UV
detection or the model with both UV and MG/MT detections>
•
Used to check all kinds of banknotes which contains UV features.
•
The UV function is automatically turned on by default when the machine is
powered up. It can also be selected or deselected by pressing the “CF” button
located in the function console.
•
If the machine detects a counterfeit note when counting, it will stop and emit
beeping sound, while the batch display will show the message “d1” and the UV
indicator will blink (alerting the user of the presence of a dubious bill).
The dubious bill will always be the last one on the stacker. Remove the dubious
bill, press “RESET” button to continue.
•
The sensitivity of UV detection can be adjusted. Hold “BATCH” button for 3
seconds, the batch display will show the current sensitivity level “AXX”, then
keep press “+” “-” button to choose the desired sensitivity level (range from 0-9).
After choosing the level, press “RESET” button to confirm/save. Do not change
other unmentioned settings, changing other setting may cause improper
working condition.
•
The bigger number means the higher sensitivity you set and “0” means deactivate
this detection function.
<MG (Magnetic)/MT (Magnetic thread) detection function <available for the
the models with both UV and MG/MT detections>
•
Used to check all kinds of banknotes which contains the mentioned features.
•
The MG/MT function is automatically turned on by default when the machine is
powered up. It can also be selected or deselected by pressing the “CF” button
located in the function console.
•
If the machine detects a counterfeit note when counting, it will stop and emit
beeping sound, while the batch display will show the message “d2” and the
MG/MT indicator will blink (alerting the user the presence of a dubious bill).
The dubious bill will always be the last one on the stacker. Remove the dubious
bill, press “RESET” button to continue.
•
The sensitivity of MG detection can be adjusted. Hold “BATCH” button for 3
seconds, then press “BATCH” again until the batch display will show the current
sensitivity level “BXX”, press “+” “-” button to choose the desired sensitivity level
(range from 0-9). After choosing the level, press “RESET” button to confirm save.