13
indicate the proper decimal point, value and
symbol.
RESISTANCE [
Ω
] MEASUREMENT
WARNING:
To avoid electric shock, disconnect
power to the unit under test and discharge all
capacitors before taking any resistance
measurements. Remove the batteries and unplug
the line cords.
1. Set the function switch to the
Ω
position.
2. Insert the black test lead plug into the negative
(COM) socket and the red test lead plug into the
positive
Ω
jack.
3. Press the MODE button until “
Ω
” appears in the
display.
4. Touch the test probe tips across the circuit or part
under test. It is best to disconnect one side of the
part under test so the rest of the circuit will not
interfere with the resistance reading.
5.
Read the resistance in the display. The display will
indicate the proper decimal point, value and
symbol.