1. Safety Information 

1.1 Warning

 

 

Self  diagnosis  and  treatment  which  use  measured  results  may  be  dangerous.  Follow  the 

instructions of your physician or licensed healthcare provider. 

 

Those  who  have  arrhythmia,  diabetes,  blood  circulation  or  apoplexy  problem,  please  use 

under the physician’s instruction. 

 

If cuff inflation doesn’t stop, remove the cuff or power off the unit,

 

otherwise, it may result in 

a hazardous condition. 

 

This equipment is not suitable for the neonate, infant and who can't communicate or interact 

independently. 

 

Do  not  use  the  blood  pressure  monitor  for  any  other  purpose  except  measuring  the  blood 

pressure of human body. 

 

Only take measurement with the manufacturer supplied cuff or AC adapter, or else it will lead 

to inaccurate results. 

 

Do  not  use  the  blood  pressure  monitor  when  you  are  close  proximity  to  strong  static 

electricity or electromagnetic fields, and avoid using the mobile during measurement. 

 

Do  not  use  in  combination  with  a  hyperbaric  oxygen  therapy  device,  or  in  an  environment 

where combustible gas may be generated. 

 

Do not install the unit in the following locations: 

- Locations subject to vibration such as ambulances and emergency helicopters. 

- A location where there is gas or flame. 

- A location where there is water or steam. 

- A location where chemicals are stored. 

- A location where the unit may easily fall. 

 

The  common  arrhythmia  such  as  atrial  premature  beats, premature  ventricular and atrial 

fibrillation will lead to inaccurate results or error. 

 

Measurements or stores need to take into account environment variables, or else it would lead 

to the inaccurate measurement. 

 

When  using  or  replacing  the AC  adapter  and  batteries, the  operator  not  to  touch  those  parts 

and the patient simultaneously. 

 

The battery has positive/negative polarity. If the battery does not connect well to the unit, do 

not forcibly connect it. 

 

Do not use Luer lock. If Luer lock connectors are used in the construction of tubing, there is a 

possibility that they might be inadvertently connected to intravascular fluid systems, allowing 

air to be pumped into a blood vessel. 

 

1.2 Precaution 

 

Do not attempt to disassemble, repair or modify the blood pressure monitor or hand cuff. 

 

Avoid high temperature, moisture, dust and direct sunlight. 

 

Clean  the  body  with  soft  and  clean  wet  cloth.  Do  not  clean  the  unit  with  alcohol  and  other 

corrosive liquids. 

 

Do not wet or cleaning the cuff with water.   

 

Clean the cuff with soft dry cloth after measurement. 

Summary of Contents for PHBPB16TL

Page 1: ...ant Noted 6 4 2 Fitting the cuff 6 4 3 Body posture during measurement 7 4 4 Take Measurement 7 4 5 Data Transmission 8 4 6 Memory 9 5 Error Indication 9 6 Trouble Shooting 9 7 Specification 10 8 Abou...

Page 2: ...o vibration such as ambulances and emergency helicopters A location where there is gas or flame A location where there is water or steam A location where chemicals are stored A location where the unit...

Page 3: ...h several trials of testing to ensure the measurement accuracy The end user should conduct a manufacturer recommended inspection and calibration annually Blood pressure measurements determined with th...

Page 4: ...Cuff Type BF Applied Part Model PHBPB16TL Applicable Arm Circumference 8 6 to 14 inches Note Symbol for TYPE BF APPLIED PART Display...

Page 5: ...r demonstration purpose It is possible these batteries will therefore not last for 200 measurements The battery life can be confirmed in the bottom right of the display If the low battery symbol is di...

Page 6: ...at can raise blood pressure Try not to take your blood pressure if you are nervous or upset If you are nervous anxious or agitated your blood pressure will rise Rest for 5 10 minutes before taking a r...

Page 7: ...ensure the measurement accuracy 4 3 Body posture during measurement Relax place the elbow on the desk with palm facing up cuff should be at the heart level Fig 9 The reading accuracy may be affected...

Page 8: ...ic pressure is greater or equal to 90mmHg as abnormal The display will flash to remind the end user of the blood pressure abnormality If the device caused any discomfort during measurement or fail to...

Page 9: ...e memory mode and turn off 5 Error Indication List of Error code Error Cause How to correct Er 30 Power on cuff inflation rate is too low or main unit does not connect with the cuff 1 Reconnect the ai...

Page 10: ...during the day which also will affect by the human emotional and physical condition 2 Record the variance and consult to the doctor If the above suggestion doesn t remediable please dial Pyle Technic...

Page 11: ...Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible...

Page 12: ...oltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Not applicable...

Page 13: ...ions equipment and the EQUIPMENT or SYSTEM The EQUIPMENT or SYSTEM is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of th...

Page 14: ...axed person and still have HBP Let s look at the facts about blood pressure so you can better understand how your body works and why it is smart to start protecting yourself now no matter what your bl...

Page 15: ...morning blood pressure and this happens in 50 of the cases Patients with morning hypertension have a 78 more chance of stroke compared with 48 of other hypertensive patients without morning high bloo...

Page 16: ...ymbol for manufacturer 0123 Symbol for CE Symbol for Follow operating instructions Symbol for TYPE BF APPLIED PART Symbol for electrical and electronic equipment IP21 Symbol for the IP classification...

Reviews: