background image

 

3. Pre Measurement 

3.1 Battery 

3.1.1 Installation and replacement 

1

 

Remove battery cover 

2

 

Load 4 standard AAA alkaline battery as indicated in figure below 

 

 

 

 

 

 

 

Fig 4 

3

 

Install back the battery cover 

4

 

Replace the battery if low battery icon is displayed 

 

If the low battery symbol 

  is displayed, replace with new batteries, otherwise 

the unit

 

will not function properly. 

 

Use 4 same brand 1.5 Volt AAA alkaline batteries. 

 

Do not mix the new and old batteries. 

 

Remove the battery if the unit is to remain unused for an extended period. 

 

Reset the time and date after battery replacement. 

3.1.2 Battery Life 

 

Four new LR03 (AAA) batteries will last for approximately 200 measurements, if 

measurements are taken once a day at room temperature (70°F). 

 

The batteries enclosed in the package are used for demonstration purpose. It is possible 

these batteries will therefore not last for 200 measurements. 

 

The battery life can be confirmed in the bottom right of the display. If the low battery 

symbol 

  is displayed, remaining power is low, replace with new batteries. 

 

3.2 Power Adapter

Optional

 

1)

 

Connect the AC adapter to the AC adapter connector of the main unit 

2)

 

Plug the socket into electric outlet.( Fig 5) 

 

AC adapter model: UE08WCP-060050SPA 

 

Use the correct adapter designed for your local voltage (AC 100~240 V) 

 

Do not plug in multiple plugs into same power outlet.         

 

Power adapter specification: Input: AC 100~240 V,   

50/60Hz, 400mA; Output: 6.0V

0.5A   

 

Use the manufacturer power adapter only. 

 

Unplug the AC adapter or wires if the device is damaged.   

 

Do not touch the AC adapter with wet hand. 

 

When operating the unit please do not tangle the power cords.                                                                                                                                                                       

Please  use  the  same  brand  battery 

and  be  aware  of  battery  polarity 

during installation                                                     

Fig 5                         

Electric outlet               

AC adapter           

AC Adapter connector             

Summary of Contents for PHBPB16TL

Page 1: ...ant Noted 6 4 2 Fitting the cuff 6 4 3 Body posture during measurement 7 4 4 Take Measurement 7 4 5 Data Transmission 8 4 6 Memory 9 5 Error Indication 9 6 Trouble Shooting 9 7 Specification 10 8 Abou...

Page 2: ...o vibration such as ambulances and emergency helicopters A location where there is gas or flame A location where there is water or steam A location where chemicals are stored A location where the unit...

Page 3: ...h several trials of testing to ensure the measurement accuracy The end user should conduct a manufacturer recommended inspection and calibration annually Blood pressure measurements determined with th...

Page 4: ...Cuff Type BF Applied Part Model PHBPB16TL Applicable Arm Circumference 8 6 to 14 inches Note Symbol for TYPE BF APPLIED PART Display...

Page 5: ...r demonstration purpose It is possible these batteries will therefore not last for 200 measurements The battery life can be confirmed in the bottom right of the display If the low battery symbol is di...

Page 6: ...at can raise blood pressure Try not to take your blood pressure if you are nervous or upset If you are nervous anxious or agitated your blood pressure will rise Rest for 5 10 minutes before taking a r...

Page 7: ...ensure the measurement accuracy 4 3 Body posture during measurement Relax place the elbow on the desk with palm facing up cuff should be at the heart level Fig 9 The reading accuracy may be affected...

Page 8: ...ic pressure is greater or equal to 90mmHg as abnormal The display will flash to remind the end user of the blood pressure abnormality If the device caused any discomfort during measurement or fail to...

Page 9: ...e memory mode and turn off 5 Error Indication List of Error code Error Cause How to correct Er 30 Power on cuff inflation rate is too low or main unit does not connect with the cuff 1 Reconnect the ai...

Page 10: ...during the day which also will affect by the human emotional and physical condition 2 Record the variance and consult to the doctor If the above suggestion doesn t remediable please dial Pyle Technic...

Page 11: ...Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible...

Page 12: ...oltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Not applicable...

Page 13: ...ions equipment and the EQUIPMENT or SYSTEM The EQUIPMENT or SYSTEM is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of th...

Page 14: ...axed person and still have HBP Let s look at the facts about blood pressure so you can better understand how your body works and why it is smart to start protecting yourself now no matter what your bl...

Page 15: ...morning blood pressure and this happens in 50 of the cases Patients with morning hypertension have a 78 more chance of stroke compared with 48 of other hypertensive patients without morning high bloo...

Page 16: ...ymbol for manufacturer 0123 Symbol for CE Symbol for Follow operating instructions Symbol for TYPE BF APPLIED PART Symbol for electrical and electronic equipment IP21 Symbol for the IP classification...

Reviews: