www.proindecsa.com / [email protected]
INSTRUCTIONS MANUAL AND MAINTENANCE
SERIE MP
9
ENG
Before starting the pump:
- Make sure that the mains voltage and frequency are the same as on the rating plate.
- Make sure that the capacitor matches the pump motor requirements (for single-phase motors).
- Make sure that the pump is fully submerged (for submersible pumps).
- Check the direction of rotation.
- Never run the pump dry.
- Never change the position of the level switch set by the manufacturer.
It is recommended to install a pipe with a larger diameter than the pump drive to reduce friction
losses as much as possible.
Install a check valve at the pump outlet to prevent the pipe from draining every time the pump
stops. Avoid bends and turns in the piping and ensure a correct connection between the piping
and the pump drive. Both cases affect the correct operation and performance of the pump.
3. INSTALLATION INSTRUCTIONS
MODELO
A
B
C
D
E
Kg
MP80
177
382
165
175
150
8
MP100
200
405
165
175
150
9
MP120
223
428
165
175
150
10
FLOW
m
3
/h
0
0,6
1,2
1,8
2,4 3,0
3,6
4,2
4,8
5,4
6
l/min
0
10
20
30
40
50
60
70
80
90
100
MODEL
DN INT (A)
POWER
CON
Ø”
220V
KW
(P
1
)
KW
(P
2
)
Hp
(P
2
)
µF
LOADING HEIGHT IN METRES
MP80
1
3,7
0,8
0,55
0,75
16
33
32
30,5 28,5
26
23
19,5 15,5
11
MP100
1
4,3
1,1
0,75
1,00
20
44
42
40
37
34
30 25,5 20,5
15
9
MP120
1
7,0
1,2
0,90
1,20
20
55
52
49
46
42
38
33
27
20,5 13,5
5