background image

Af

t

er running the application, the following options are available on the screen:

6. 

START OF OPERATION

offline

” mode

Wi-Fi network selection

list  of  the  selected  network  drivers  with 

which  the  user  can  connect,  driver  IP 

address

NOTE: 

The  application  has  access  to  smartphone  network  settings  and  enables  the  Wi-Fi 

function when running the application.

For more information about the device, press and hold the tile with its name. Information will be 

displayed in a new window:

change of settings of DHCP protocol, IP 

address, MASK and gateway address

 

8

6.1. 

Information about the device and change of network settings

refreshing the list of available drivers

[

Mac

]  - 

MAC  address  (unique  for  each 

network device)

[

Mask

],  [

Gateway

]  - 

current  network 

parameters of the driver

[

Serial

] - 

device serial number

[

Firmware

], [

Bootl

.] - 

firmware version and 

driver bootloader

It  is  possible  to  edit  network  settings.  For  this 

purpose press

       . 

The program displays the editing 

window in which it will be possible to change

[

Controller name

] - 

the maximum length of a new 

name is 16 characters

[

Auto-use  DHCP

]  - 

if  the  function  is  selected, 

address will be automatically assigned from a DHCP 

server, if not – a static address will be used

[IP

 

address

], 

[Network mask]

,

 [Gateway address]

 

static network parameters of the driver

Summary of Contents for SwitchDimm PX387

Page 1: ...MANUAL SwitchDimm DMX Controller R PX387...

Page 2: ...ating configurations 7 1 Edit zones 7 2 Editing of channels in the zone 8 Control 9 Safety 10 Configuration 11 Technical drawing 12 Technical specification Declaration of conformity 3 3 4 5 7 8 8 9 10...

Page 3: ...ded 8 The device cannot be turned on in places with humidity exceeding 90 9 The device cannot be used in places with temperature lower than 2 C or higher than 40 C 10 Clean with damp cloth only The PX...

Page 4: ...4 3 CONNECTION DIAGRAM V V L N effects e g PxArt laps Power Supply 12 24V DC...

Page 5: ...u should configure network parameters in such a way that the controller is able to operate on the subnet and there is no conflict of IP addresses devices in the network must have unique IPaddresses Th...

Page 6: ...receives configuration on its own Router e g IP 192 168 0 100 Mask 255 255 255 0 DHCPserver PX387 IP mask and gate optional DHCP Smartphone IP 192 168 0 2 Mask 255 255 255 0 Default gateway 192 168 0...

Page 7: ...TION 7 2 Go to your phone settings and then check Allow installation of apps from sources other than the Play Store in the Security tab 3 Open the application through the system File Manager The new s...

Page 8: ...teway address 8 6 1 Information about the device and change of network settings refreshing the list of available drivers Mac MAC address unique for each network device Mask Gateway current network par...

Page 9: ...r 9 page 14 The application can also be used offline without having to log in to the driver The offline mode is in the menu available under the smartphone menu pushbutton Should the device not be equi...

Page 10: ...consists of the following components log out from the driver name of the currently displayed tab workspace of the application window the main panel 6 3 Structure of the application window drop down m...

Page 11: ...list determines the order of desktops Zone editing allows you to change the zone name and specify the number of columns in which buttons are to be displayed The number of columns determines the size...

Page 12: ...l range selection screen 1 512 If you select a range the above described options will apply only to the selected range Don t show occupied channels select to hide channels assigned to another zone on...

Page 13: ...s screen Security switching to the Security screen Configuration switching to the Configuration screen Options Edit zones Security and Configuration are available only to the administrator 8 CONTROL T...

Page 14: ...password and type the new one twice 10 CONFIGURATION The Configuration tab allows you to save your settings in a file on your phone It will have the default extension cfg387 This is possible when you...

Page 15: ...PECIFICATION power supply no load current consumption output DMX channel communication port programmable zones weight dimensions 12 24V DC 70 mA for 12V DC 40 mA for 24V DC 512 LAN 16 0 11 kg Width 70...

Page 16: ...cy PXM Marek upnik sp k ul Przemys owa 12 30 701 Krak w SwitchDimm DMX Controller Px387 PN EN 55103 1 2012 PN EN 55103 2 2012 PN EN 61000 4 2 2011 PN EN 61000 6 1 2008 PN EN 61000 6 3 2008 DMX signal...

Reviews: