PXM PX816-T User Manual Download Page 5

The PX816-T device is powered directly from 230V power grid. Failure to 

comply with the safety rules may result in electric shock and may endanger 
the user’s life. Therefore it is necessary to observe the following:

1. Installation should be performed by a person holding the appropriate 

qualifications, according to the instruction manual.

2. The electrical installation to which the lamp is to be connected must 

meet the safety requirements (the installation must be 3-wire and 
equipped with a residual current device).

3. All the conductors should be protected against mechanical and 

thermal damage.

4. In the event of damaging any conductor, it should be replaced with

a conductor of the same technical data.

5. All repairs, should be made with cut off power supply.
6. Do not connect to the power supply to device with visible damage.
7. All sudden shocks, particularly dropping, should be avoided.
8. The device cannot be used in places with temperature lower than +2°C

or higher than +40°C.

9. Clear with damp cloth only.

5

Summary of Contents for PX816-T

Page 1: ...PX816 T PxArt XL Mono DALI Track User manual...

Page 2: ...ion of the GT Pulse Control 7 5 Connection scheme 8 6 Dimensions 9 7 Technical data 10 Manufacturer reserves the right to make modifications in order to improve device operation PXM Marek upnik sp k P...

Page 3: ...adiation very high CRI color rendering index high brightness and low energy consumption The device has a handle that allows it to be mounted to GLOBAL Trac Pulse Control bus bars with an integrated po...

Page 4: ...s Warning Read the instruction manual Caution Do not look at the LEDs LEDs can cause damage or eye irritation Do not look at the light source with any optical devices that focus the light rays Light i...

Page 5: ...d must meet the safety requirements the installation must be 3 wire and equipped with a residual current device 3 All the conductors should be protected against mechanical and thermal damage 4 In the...

Page 6: ...cription of the PX816 T markings and their explanation PX816 T BB XX YYY Z BB version XL large COB XX reflector angle 15 15 36 36 51 51 YYY CRI and color temperature X30 CRI 95 temp 3000K 930 CRI 90 t...

Page 7: ...a device attached to the GLOBAL Trac Pulse Control rail using an adapter with a built in power supply included in the set 4 1 The cross section of the GT Pulse Control 7 phase 3 phase 1 phase 2 neutra...

Page 8: ...5 Connection scheme 8 1 3 phase GLOBAL Trac Pulse Control bus bar end feed power supply cable GLOBAL Trac Pulse Control adapter with built in power supply and DALI receiver DALI control line cable...

Page 9: ...6 Dimensions 9 87...

Page 10: ...wer factor 0 94 max increase of the housing temperature 50 C color rendering index CRI min 80 lifetime of diodes 50000h reflector angles 15 36 51 brightness adjustment range 0 2 100 control DALI mount...

Page 11: ...61000 3 2 2019 EN 62471 2008 EN 62386 101 2014 EN 62386 102 2014 and meets the essential requirements of the following directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of...

Reviews: