PXM PX156 User Manual Download Page 1

PX156

MultiSystem Dimmer

2 x 1200W

User manual

Summary of Contents for PX156

Page 1: ...PX156 MultiSystem Dimmer 2 x 1200W User manual...

Page 2: ...g 13 6 2 Analog input settings 14 6 2 1 Group parameters 14 6 2 2 Individual parameters 15 6 2 3 Temperature 16 6 2 4 Input mode 16 6 3 Function diagrams for external button control 17 6 3 1 Function...

Page 3: ...rol 30 12 Dimensions 31 13 Notes 31 14 Technical data 32 Manufacturer reserves the right to make modifications in order to improve device operation PXM Marek upnik sp k Pod e 654 32 003 Pod e BDO regi...

Page 4: ...channel control characteristics linear linear inverse logarithmic exponential switched ON OFF three neon control characteristics ACL limiting the output voltage in the range of 50 230V with an accura...

Page 5: ...as protection installation separate PE strand in working order only 3 strand grid 3 All the conductors should be protected against mechanical and thermal damage 4 In the event of damaging any conducto...

Page 6: ...The device cannot be turned on in places with humidity exceeding 90 14 The device cannot be used in places with temperature lower than 2 C or higher than 40 C NOTE 1 Improper connection of the protec...

Page 7: ...a particular channel show in percentage Limit output voltage limitation in a range from 50 to 230V DMX address selected in a range from 1 509 Group parameters C01 C02 number of the edited channel 7 D...

Page 8: ...ature Number of chaser steps available values from 1 to 8 No DMX signal recently controlled values maintaining Individual programming parameters Linear characteristic Logarithmic characteristic Invert...

Page 9: ...address or displays AdC lettering meaning analog control mode Pressing Esc during normal operation will test the display all the segments should get On state Press Enter to switch to the main menu the...

Page 10: ...he internal dimmer temperature 4 Analog digital mode of operation switching AdC the function to switch between digital control mode DMX or analog control 0 10V signal or monostable external button 5 S...

Page 11: ...e 9 options to choose from Lin linear SP switchable Inu inverted LnU logarithmic E_P exponential nE1 nE3 for neon lamps control Li2 linear 15 100 zero value at the power output for DMX values of 0 15...

Page 12: ...efined chaser AnL analog mode activation in the absence of DMX e g it allows to control using the connected external momentary buttons 6 1 2 Individual parameters 1 Adr DMX address from the range 1 to...

Page 13: ...ting On 6 1 5 Scenes and chaser programming 1 Sc1 Sc4 scenes programming C01 C02 edited channel number 0 100 channel brightness in percentage 2 CrP user defined chaser F01 F08 editable pattern numbers...

Page 14: ...for 10V maximum brightness using a 10k linear potentiometer or an external control voltage bIn settings for external monostable button control Fun 5 functions to choose from see charts in item 6 3 rIS...

Page 15: ...1 AIn analog control input settings for each channel AnL voltage control 0 10V for 0V total dimming for 10V maximum brightness using a 10k linear potentiometer or an external control voltage bIn sett...

Page 16: ...sary Dimmer has been equipped with thermal protection with the following settings for the temperatures inside the dimmer 60 C automatic start of the electronically controlled fan 90 C 10 drop in power...

Page 17: ...button control 6 3 1 Function one 6 3 2 Function two 17 Time Rising time parameter rIS Button held pressed MAX ACL MIN Button released Time Rising time parameter rIS Short press 500 ms MAX ACL MIN Bu...

Page 18: ...Rising time parameter rIS Short press 500 ms MAX ACL MIN Short press 500 ms Short press 500 ms Short press 500 ms Time Rising time parameter rIS Fall down time rising time Duration time parameter LAS...

Page 19: ...ther three are ignored 6 3 5 Function five Pressing and holding the external button A causes rise of the brightness Once it is released the brightness stops to increase Pressing and holding the extern...

Page 20: ...ption to code programming effects programmer defined number from range 1 to 255 Such situation other users can only read defined parameters without possibility of modification With the parameters code...

Page 21: ...atically terminate locking procedure and return to programmed operation 7 2 Switching the access lock off 1 Press Esc enough times to leave dimmer programming mode the display will show finally DMX ad...

Page 22: ...rd will display bAd Nit is necessary to start unlocking procedure from beginning The third time wrong password setting lock the dimmer permanently displaying Loc The telephone contact to service is ne...

Page 23: ...T ENTER NEXT NEXT NEXT ENTER NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT ENTER ENTER ENTER NEXT ENTER NEXT NEXT NEXT PREV ENTER NEXT ENTER NEXT ENTER NEXT ENTER NEXT ENTER ENTER NEXT NEXT ENTER NEXT...

Page 24: ...ultiplied by 10 and the setting accuracy is reduced to tens of seconds 24 ENTER NEXT NEXT NEXT ENTER ENTER NEXT NEXT NEXT NEXT NEXT NEXT ENTER NEXT ENTER NEXT NEXT NEXT PREV NEXT ENTER ENTER NEXT ENTE...

Page 25: ...the T35 mounting rail To install the device it should be applied to the rail as shown in the figure on the left then hook the movable hook to the upper edge of the rail The next step is to push the d...

Page 26: ...en to the DMX coupling of the dimmer and then driven out from the same coupling refer to the scheme below to the next DMX 512 signal receivers If MultiSystem Dimmer is installed as the last device in...

Page 27: ...1 1 DMX 512 signal control 27 REFLECTORS max 2 x 1200W NEUTRAL STRAND PROTECTIVE STRAND PHASE STRAND 230V POWER SUPPLY RCCB with overload type C 10A PE L OUT 2 N OUT L OUT 1 DMX CONTROLLER DMX DMX GND...

Page 28: ...ar potentiometers 28 REFLECTORS max 2 x 1200W NEUTRAL STRAND PROTECTIVE STRAND PHASE STRAND 230V POWER SUPPLY RCCB with overload type C 10A PE L OUT 2 N OUT L OUT 1 CW CW 10k POTENTIOMETERS 10V OUT GN...

Page 29: ...0V control 29 REFLECTORS max 2 x 1200W NEUTRAL STRAND PROTECTIVE STRAND PHASE STRAND 230V POWER SUPPLY RCCB with overload type C 10A PE L OUT 2 N OUT L OUT 1 0 10V CONTROL SIGNAL SOURCES GND 0 10V IN...

Page 30: ...ostable buttons control 30 REFLECTORS max 2 x 1200W NEUTRAL STRAND PROTECTIVE STRAND PHASE STRAND 230V POWER SUPPLY RCCB with overload type C 10A PE L OUT 2 N OUT L OUT 1 MONOSTABLE BUTTONS 0 10V IN 0...

Page 31: ...ated to inductive load control as for neon lamp transformers Differences between characteristics are only in lamp switching level so the start brightness of the lamp The suitable characteristic should...

Page 32: ...ion input 0 10V 1mA load capacity of the control output 10V out 10mA thermal protection 60 C automatic launch of electronically controlled fan 90 C output power decrease by 10 100 C automatic dimmer s...

Page 33: ...following directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipm...