1. To connect devices use of the microphone cable
is recommended (two strands in the shield).
2. The devices should be connected in series.
3. To split the DMX line it is necessary to use the
DMX SPLITTER (PX094).
4. In case of the great number of devices or long
distances use the DMX REPEATER (PX097). It
is an amplifier of the DMX signal.
5. In the last device a terminator should be installed.
It is a 110 Ohm resistor.
1. ground
2. DMX (-)
3. DMX (+)
PUSH
THE LAST
DEVICE
RESISTOR
1
2
3
110 Ohm
PUSH
1
2
3
SHIELD
DMX -
DMX +
10. DMX SIGNAL CONNECTION
11. TECHNICAL SPECIFICATION
1 - 512
yes
yes
yes
electronically controlled
12 x 1200 W continuous load (resistantive)
12 x 700 VA continuous load (inductive)
6 A automatic fuses
3-pin XLR plug
3-pin XLR socket
3 x 230 V / 40 - 70 Hz
cable
3 x 22 A (at full load)
15 kg
400 mm
415 mm
100 mm
- DMX channels
- DMX line optical insulation
- circuit break detection
- supertension protection
- fans
- outputs load capacity
- outputs protection
- DMX control input
- DMX control output
- power supply
- output socket
- current consumption
- weight
- dimensions:
- width
- heigth
- depth
10