PXM Gate 2 DMX RDM PoE User Manual Download Page 1

PX760

Gate 2

DMX RDM PoE

User manual

Summary of Contents for Gate 2 DMX RDM PoE

Page 1: ...PX760 Gate 2 DMX RDM PoE User manual...

Page 2: ...5 7 Presets menu 15 5 8 Settings for the other parameters 16 5 9 Setting the display contrast 16 6 Information communicated by LED indicators 18 7 PX760 cooperation with the grandMA2 console 20 8 Art...

Page 3: ...s HTP and LTP The protocol version is Art Net4 compatible with Art Net 1 4 The device is equipped with two DMX RDM ports working in IN OUT modes and one Ethernet port operating in the 10 100BaseTX sta...

Page 4: ...ging any conductor it should be replaced with a conductor of the same technical data and attestations 4 Connection of DMX signal can only be made with shielded conductor 5 All repairs and connections...

Page 5: ...3 Connectors and control elements 5 LED indicators display programming buttons...

Page 6: ...supply from an external power supply no power supply included Power supply using twisted pair cable is possible with simultaneous data transfer The most important features of PoE power supply and dat...

Page 7: ...s you to enter the programming mode and confirm the values set Where a particular parameter is editable in the bottom right hand corner the edit symbol and pressing allows you to proceed to edit the f...

Page 8: ...e the gate static IP address IP address static sub net mask Subnet mask default static gate Gateway address turn on On or turn off Off the DHCP protocol DHCP UDP port UDP port The default port for the...

Page 9: ...Merge mode For each port the settings can be changed in the Art Net network configuration ART NET config in the Port n menu option in the Direction option Information about the status of ports is avai...

Page 10: ...ection out ArtNet DMX NEXT Direction out ArtNet DMX Direction in DMX ArtNet 3 x NEXT NEXT ENTER Universe 0 0x0000 Universe 0 0x0000 NEXT ENTER Universe switch 0 0x0 Universe switch 0 0x0 ENTER Merge m...

Page 11: ...ol range 0 127 dec 0x0 0x7f hex 11 ENTER DMX parameters NEXT Output channels Auto NEXT ENTER Output channels 512 Break time 176us Output channels Auto Break time 176us ENTER previous page previous pag...

Page 12: ...addressing where the gate has a common value for the fields Net and Sub Net for all the four ports Universe switch universe number in the Art Net protocol range 0 15 dec 0x0 0xf hex Individual settin...

Page 13: ...hannel from the start bits of another channel range 0 s 76 s Output channels defines the number of channels sent out through a given port Settings Auto the number of channels in a port is equal to the...

Page 14: ...ch options are available Unicast transmission in which exactly one packet is sent to exactly one recipient there is only one sender and only one recipient After selecting this option the recipient s I...

Page 15: ...000 Universe 0 0x0000 NEXT ENTER Universe switch 0 0x0 Universe switch 0 0x0 ENTER Merge mode LTP NEXT Merge mode LTP Merge mode HTP NEXT ENTER Transmission Auto Transmission Auto NEXT NEXT NEXT Trans...

Page 16: ...f the other parameters To restore the backlight press any key At the level of this menu it is also possible to check the number of detected devices supporting the RDM protocol on a given DMX port Num...

Page 17: ...ssing the 10x Esc button the device will signal being in the Contrast menu by flashing the DMX signal diodes alternately in blue and orange With the Next or Previous button the appropriate value shoul...

Page 18: ...te transmission using merging i e output data are a result of combining data from two Art Net sources blinking in orange only RDM packets transmission through a given port blinking orange at a faster...

Page 19: ...DMX signal if Stop DMX signal is off Off the port will continue to send the last values and the diode will continue to blink in blue if Stop DMX signal is on On after the time period Timeout value tra...

Page 20: ...uto discovery on enabled the gate will continuously search for RDM devices The next step is to enable RDM support in the grandMA2 console To do this go to Setup Console Global Settings Select RDM opti...

Page 21: ...address set so that the console is in the same network as the gate If Gate 2 DMX RDM is on the 2 x x x network with the mask of 255 0 0 0 then for the device to work together the console must be on th...

Page 22: ...for the devices supporting the RDM protocol the console is in the same network as the gate and has enabled RDM and Art Net Output Active support After adding the main RDM window to the main scree you...

Page 23: ...ported in PX760 Name Value OpPoll 0x2000 OpPollReply 0x2100 OpOutput OpDmx 0x5000 OpSync 0x5200 OpAddress 0x6000 OpInput 0x7000 OpTodRequest 0x8000 OpTodData 0x8100 OpTodControl 0x8200 OpRdm 0x8300 Op...

Page 24: ...Firmware 4 Using the magnifying glass button located to the right of the update access path download the file with alf extension 5 In the Compatible Devices field select again the device to update 6 I...

Page 25: ...25...

Page 26: ...10 Connection scheme 26 DMX512 devices DMX512 devices Art Net network PoE 48V DC power socket...

Page 27: ...12 mode with a 48V DC power supply connected Driver 48V DC Router b device operating in DMX512 Art Net mode using PoE power supply in the IEEE 802 3af standard R o u t e r s w i t c h with PoE power s...

Page 28: ...11 Dimensions 28...

Page 29: ...rsion Art Net 1 2 3 4 communication method Art Net display and buttons firmware update through Art Net 4 protocol default user presets 2 2 x x x and 10 x x x indications mode Normal Mute Identify No s...

Page 30: ...dimensions width 127mm height 42mm depth 99mm Art Net Designed by and Copyright Artistic Licence Holdings Ltd 30...

Page 31: ...wing directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment T...

Reviews: