background image

1

The PX232 Relay Module is a device used to switch effects of stage and architectural illuminators 
via DMX-512 signal.
The module contains a transmitter that controls the on / off output. It has a built-in hysteresis, 
which eliminates vibration of relay phenomena during switching on and off. The PX232 switches 
on output when the DMX value is over 191. Relay switches off the output after reaching 64 value 
or below. 
Method of hysteresis operation is shown below.

The device is equipped with DMX signal input and output. Its housing is adapted for mounting on 
DIN rails and is 35 mm wide (the size of 2-modules).

1. GENERAL DESCRIPTION

2. SAFETY CONDITIONS

The PX232 is a device powered directly from power grid 230V, what may result in electric shock  

in case of not following safety rules. During its installation and use the following rules must be 

strictly observed:

1. Installation of the device should be carried out by a person with appropriate qualifications in 

accordance with this document.

2. The electrical outlet to which the switch is connected have to be linked to a working protective 

installation (3-wire installation.)

3. Protect the power cord from mechanical and thermal damage.

4.  In  case  of  damage  the  power  cord,  cable,  replace  it  with  the  same  technical  data  and 

certificates.

5. For connecting devices to the 1 Relay Module use only 3-wire cables with cross-section of not 

less than 1.5 mm.

6. Connection of DMX signal can only be made with shielded conductor.
7. All repairs and connections of outputs or DMX signal can only be made with cut off power 

supply.

8. PX215 should be strictly protected against contact with water and other liquids.
9. All sudden shocks, particularly dropping, should be avoided.
10. The device cannot be turned on in places with humidity exceeding 90%.

o

o

11. The device cannot be used in places with temperature lower than 2 C or higher than 40 C. 
12. Clean it with damp duster only.

OFF

ON

DMX value

64

0

191

Summary of Contents for 1 Relay Module

Page 1: ...MANUAL 1 Relay Module PX232 R...

Page 2: ...address settings 5 Connection Diagram 6 Technical Drawing 7 Technical Data 8 Declaration of Conformity Manufacturer reserves the right to make modifications in order to improve device operation PXM s...

Page 3: ...tallation of the device should be carried out by a person with appropriate qualifications in accordance with this document 2 The electrical outlet to which the switch is connected have to be linked to...

Page 4: ...ENTS DESCRIPTION DMX 512 Output DMX dipswitches address Power supply DMX 512 Input Output control diode DMX signal control diode On Off type output www pxm pl L N 230 VAC DMX IN PX 232 DMX OUT GND POW...

Page 5: ...1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8 9 9 9 9 9 ON ON ON ON ON DIP DIP DIP DIP DIP 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8...

Page 6: ...N L Residual Current Circuit Breaker RCCD 6A PX232 must be connected to the DMX line in series This means that to the DMX IN terminal control cable should be connected and then from the DMX OUT termin...

Page 7: ...16 mA 35 mm 2 modules 60 mm 85 mm DMX channels Number of output channels Output load Connections Power supply Current consumtion Dimensions Width Height Lenght 7 TECHNICAL DATA 5 35 mm 85 mm 58 mm www...

Page 8: ...f producer Address of producer declares that the product Name of product Type answers the following product specifications LVD EMC Additional informations Krak w 13 11 2009 DECLARATION OF CONFORMITY a...