PXFLOW PX0 Operating Instructions Manual Download Page 3

 

 

 

 

 

   

the lifting handle, do not use the cables or 

discharge hose. All fixing screws and bolts must 

be securely fasted before lifting. Human injury 

may appear if above is not secured. 

After a long period of storage the pump must be 

inspected carefully. Rotate the impeller by hand 

before start-up and check carefully seals  and 

cable entry 

 

Installation 

 

When installing the pump, reduce the risk of 

accidents, be aware that the machine is 

extremely heavy and contain electrical open 

wires. 

 

Before starting the installation, secure that all 

screws for the lift handle, stator and volute fixing 

bolts are safety tighten. 

 

Lifting chains, cranes etc. must always be 

designed to encounter without cracked the 

weight of the  pump. For safety reasons never 

walk under suspended load. 

 

Discharge connection bracket - 

DCB 

Place the base elbow (DCB) at the bottom of 

the sump. If one 

pump is installed, 

place the pump in 

the center of the 

tank. Fit the guide 

tubes to the upper 

guide bracket so 

they are in an 

accurate vertical 

and parallel position 

to each other. 

 

Connect the discharge pipe to  the DCB and 

mount eventual the pipe with a non return valve 

and gate valve which suits the flow velocity from 

the pump. 

 

The lifting tackle must be installed directly at the 

point above the center of gravity of the pump 

while the pump automatically will release from 

the DCB (which is appropriate shaped for this 

purpose) when lifted vs. fasten on the DCB 

when lowered. 

 

Dry pit installation 

PX series with cooling jacket  can be installed 

dry can be supplied with adjustable support. 

The support consists of three legs of telescopic 

type. The suction pipe 

can be connected in 

either direction by 

changing over the 

location of the legs. The 

legs after adjusting are 

fixed with two screws to 

lock the position.  

Secure the legs by 

bolting in concrete. 

The suction connection 

pipe can be connected vertical under the pump. 

The motor unit is easier to remove and fit 

in place again if the suction pipe is 

equipped with a drain valve. This can be 

opened when the motor is going to be 

fitted or removed. 

 

The discharge pipe should be mounted 

with a drain as well, in order to let out air 

under the first start-up. Afterwards it can 

be fitted with a manometer to measure the 

pressure. 

 

Before start, check carefully the cables for 

defects and check the level of coolant in 

the cooling jacket. 

 

Portable version / installation 

This version needs 

extra attention 

while operating. 

The pump can be 

supplied with a 

support ring. 

 

Place the pump on 

a firm surface and 

keep the cables 

straight, secure 

that cable are not nipped. 

 

If risk of overturning, place and fit the 

pump on a steel plate. 

When hoses are used as discharge 

connection, remember that friction losses 

are higher than in a pipe and flow might be 

less than expected. 

 

Venting of the volute 

After lowering the pump into a sump full of 

water, an air lock may occur in the volute 

and cause pumping problems. In this case, 

raise the pump in the medium and then 

lower it again. If necessary repeat this 

venting procedure. 

If the problem insists then we can drill a 

hole 2-3mm on the vent’s plug. 

 

Especially for the pumps of dry installation 

it is necessary to venting them again 

(when have been installed at the final 

position) by the appropriate hole at the 

volute of the pump. 

 

Electrical connections 

The electrical installation must be 

inspected by authorized electrician before 

switching-on. 

Make sure that the electrical terminals or 

starting equipment is installed in such way 

that it cannot be flooded. The electrical 

installation must apply to national 

regulations. 

All pumps are supplied with built-in thermal 

switches in the stator windings. These are  

marked F1, F2 and must always be 

connected in series to the control circuit of 

control panel. 

 

D is connected to a moisture sensor which 

is located between the oil chamber and 

stator housing. This sensor should be 

connected to a conductive liquid level relay 

in the control panel. An alarm should be 

given in event of moist.  Your local 

PXFLOW representative can supply you 

with the conductive liquid level relay 

(optional). 

 

Make sure that the power supply, voltage, 

frequency and starting method 

corresponds to the nameplate data fitted 

on the pump. 

 

The motor can operate by voltage 

tolerances at +/-  5%. The motor might be 

overloaded and burned out if this is 

exceeded. 

 

About power supply cable, and control 

cable connections see to motor winding 

connection schemes in this manual. 

 

Direct online starting DOL 

 

Star-Delta starting  Y-Δ 

 

Starting equipment on the control panel, 

must be provided with over current 

protection sensitive to phase failure. A 

3phase asymmetry control relay is 

recommended, adjusted to 15% phase 

asymmetry 

 

The power supply should be fused with 

low-blow fuses. 

15  Starts per hour (regularly spaced) are 

permitted 

 

Replacing the power cable 

If the cable has been compressed or 

damaged it must be replaced to avoid 

water entry. 

 

When changing the cable always change 

the rubber joint-ring too, in the entry of it. 

Never change dimensions from the original 

one, as water may enter the motor. 

 

If the same cable is re-used due to any 

repair work, always cut away a piece at the 

cable entry in order to seal on a non 

compressed cable sheath. 

 

For safety reasons the grounded conductor 

should be longer than the others, these of 

the phases. If the motor cable is 

accidentally wrenched off, the earth 

conductor should be the last to break away 

from its terminal. This applies to both ends 

of the cable. 

 

Electromagnetic Compatibility, 

EMC 

The pump does not generate any electric 

noise EMC, which can infect on other 

equipment. However, if the pump is power 

supplied via frequency inverter, power 

cables might need screening. 

 

The pump apply to directive 

EN89/336/EEC regarding EMC. 

 

 

 

WARNING! The pump unit doesn’t go with 

the base. 

The base as also others hydraulics 

accessories for the installation and the 

connection of  the pump with the system 

can be supplied from our company. 

 

 

 

 

 

WARNING! Never remove the support 

ring, human contact might occur and 

make injury. 

 

 

 

 

 

WARNING! For the safety operation it 

is necessary to have succeeded the 

appropriate support of the pump unit as 

do not have any accident mainly at the 

start of the pump. 

 

 

 

 

CAUTION! All electrical equipment 

must always be earthed (grounded). 

This applies both to the pump and to 

any monitoring equipment. 

 

 

 

 

 

 

 

   

the lifting handle, do not use the cables or 

discharge hose. All fixing screws and bolts must 

be securely fasted before lifting. Human injury 

may appear if above is not secured. 

After a long period of storage the pump must be 

inspected carefully. Rotate the impeller by hand 

before start-up and check carefully seals  and 

cable entry 

 

Installation 

 

When installing the pump, reduce the risk of 

accidents, be aware that the machine is 

extremely heavy and contain electrical open 

wires. 

 

Before starting the installation, secure that all 

screws for the lift handle, stator and volute fixing 

bolts are safety tighten. 

 

Lifting chains, cranes etc. must always be 

designed to encounter without cracked the 

weight of the  pump. For safety reasons never 

walk under suspended load. 

 

Discharge connection bracket - 

DCB 

Place the base elbow (DCB) at the bottom of 

the sump. If one 

pump is installed, 

place the pump in 

the center of the 

tank. Fit the guide 

tubes to the upper 

guide bracket so 

they are in an 

accurate vertical 

and parallel position 

to each other. 

 

Connect the discharge pipe to  the DCB and 

mount eventual the pipe with a non return valve 

and gate valve which suits the flow velocity from 

the pump. 

 

The lifting tackle must be installed directly at the 

point above the center of gravity of the pump 

while the pump automatically will release from 

the DCB (which is appropriate shaped for this 

purpose) when lifted vs. fasten on the DCB 

when lowered. 

 

Dry pit installation 

PX series with cooling jacket  can be installed 

dry can be supplied with adjustable support. 

The support consists of three legs of telescopic 

type. The suction pipe 

can be connected in 

either direction by 

changing over the 

location of the legs. The 

legs after adjusting are 

fixed with two screws to 

lock the position.  

Secure the legs by 

bolting in concrete. 

The suction connection 

pipe can be connected vertical under the pump. 

The motor unit is easier to remove and fit 

in place again if the suction pipe is 

equipped with a drain valve. This can be 

opened when the motor is going to be 

fitted or removed. 

 

The discharge pipe should be mounted 

with a drain as well, in order to let out air 

under the first start-up. Afterwards it can 

be fitted with a manometer to measure the 

pressure. 

 

Before start, check carefully the cables for 

defects and check the level of coolant in 

the cooling jacket. 

 

Portable version / installation 

This version needs 

extra attention 

while operating. 

The pump can be 

supplied with a 

support ring. 

 

Place the pump on 

a firm surface and 

keep the cables 

straight, secure 

that cable are not nipped. 

 

If risk of overturning, place and fit the 

pump on a steel plate. 

When hoses are used as discharge 

connection, remember that friction losses 

are higher than in a pipe and flow might be 

less than expected. 

 

Venting of the volute 

After lowering the pump into a sump full of 

water, an air lock may occur in the volute 

and cause pumping problems. In this case, 

raise the pump in the medium and then 

lower it again. If necessary repeat this 

venting procedure. 

If the problem insists then we can drill a 

hole 2-3mm on the vent’s plug. 

 

Especially for the pumps of dry installation 

it is necessary to venting them again 

(when have been installed at the final 

position) by the appropriate hole at the 

volute of the pump. 

 

Electrical connections 

The electrical installation must be 

inspected by authorized electrician before 

switching-on. 

Make sure that the electrical terminals or 

starting equipment is installed in such way 

that it cannot be flooded. The electrical 

installation must apply to national 

regulations. 

All pumps are supplied with built-in thermal 

switches in the stator windings. These are  

marked F1, F2 and must always be 

connected in series to the control circuit of 

control panel. 

 

D is connected to a moisture sensor which 

is located between the oil chamber and 

stator housing. This sensor should be 

connected to a conductive liquid level relay 

in the control panel. An alarm should be 

given in event of moist.  Your local 

PXFLOW representative can supply you 

with the conductive liquid level relay 

(optional). 

 

Make sure that the power supply, voltage, 

frequency and starting method 

corresponds to the nameplate data fitted 

on the pump. 

 

The motor can operate by voltage 

tolerances at +/-  5%. The motor might be 

overloaded and burned out if this is 

exceeded. 

 

About power supply cable, and control 

cable connections see to motor winding 

connection schemes in this manual. 

 

Direct online starting DOL 

 

Star-Delta starting  Y-Δ 

 

Starting equipment on the control panel, 

must be provided with over current 

protection sensitive to phase failure. A 

3phase asymmetry control relay is 

recommended, adjusted to 15% phase 

asymmetry 

 

The power supply should be fused with 

low-blow fuses. 

15  Starts per hour (regularly spaced) are 

permitted 

 

Replacing the power cable 

If the cable has been compressed or 

damaged it must be replaced to avoid 

water entry. 

 

When changing the cable always change 

the rubber joint-ring too, in the entry of it. 

Never change dimensions from the original 

one, as water may enter the motor. 

 

If the same cable is re-used due to any 

repair work, always cut away a piece at the 

cable entry in order to seal on a non 

compressed cable sheath. 

 

For safety reasons the grounded conductor 

should be longer than the others, these of 

the phases. If the motor cable is 

accidentally wrenched off, the earth 

conductor should be the last to break away 

from its terminal. This applies to both ends 

of the cable. 

 

Electromagnetic Compatibility, 

EMC 

The pump does not generate any electric 

noise EMC, which can infect on other 

equipment. However, if the pump is power 

supplied via frequency inverter, power 

cables might need screening. 

 

The pump apply to directive 

EN89/336/EEC regarding EMC. 

 

 

 

WARNING! The pump unit doesn’t go with 

the base. 

The base as also others hydraulics 

accessories for the installation and the 

connection of  the pump with the system 

can be supplied from our company. 

 

 

 

 

 

WARNING! Never remove the support 

ring, human contact might occur and 

make injury. 

 

 

 

 

 

WARNING! For the safety operation it 

is necessary to have succeeded the 

appropriate support of the pump unit as 

do not have any accident mainly at the 

start of the pump. 

 

 

 

 

CAUTION! All electrical equipment 

must always be earthed (grounded). 

This applies both to the pump and to 

any monitoring equipment. 

 

 

3

Summary of Contents for PX0

Page 1: ...oumelis Kapetan Zacharia ex Afon Ntouna 1 13677 Acharnes Attiki Greece Tel 30 210 2431111 FAX 30 210 2431601 E mail sales papantonatos gr www papantonatos gr Operating instructions for PXFLOW sewage pumps Standard units ...

Page 2: ...1 80 83 PX2 PX3 PX4 PX5 PXGRIND can equipped with a closed internal cooling system standard for dry pit installation option for wet and portable installation type The closed internal cooling system functions as follows An internal impeller located between the two mechanical shaft seal circulates the cooling liquid in a closed loop through channels to a cooling jacket surrounding the stator housing...

Page 3: ... of the pump with the system can be supplied from our company WARNING Never remove the support ring human contact might occur and make injury WARNING For the safety operation it is necessary to have succeeded the appropriate support of the pump unit as do not have any accident mainly at the start of the pump CAUTION All electrical equipment must always be earthed grounded This applies both to the ...

Page 4: ... regulations Fasten the plug so that the lower but not the top O ring gasket seals Loosen the plug marked inlet and fill up with oil and then fasten both oil plugs Use oil with same quality and performance as Enerpar M002 white oil NOTE Old oil should be entrusted to an oil disposal company in accordance with local regulation WARNING As the pump will pump up to 70 of the nominal flow at wrong rota...

Page 5: ...es Moisture PE 3 Direct on line starting DOL Motor connection Power Supply V Brawn W Grey PE Yellow F1 Black Control F2 Brawn D Grey 1 Power Supply and Control Cable Color Coding U Black 1 V Black 2 W Black 3 PE Yellow F1 Black 4 F2 Black 5 D Black 6 Internal Connection on Motor s Terminal Board U1 U2 Black V1 V2 Red W1 W2 Orange 7 5 ...

Page 6: ...cable2 W2 Grey PE Yellow F1 Black Control F2 Brawn D Grey 1 Power Supply Cable 1 Control Cable 1 Power Supply and Control Cable Color Coding U1 Black 1 V1 Black 2 W1 Black 3 PE Yellow Power Supply U2 Black 4 V2 Black 5 W2 Black 6 PE Yellow F1 Black Control F2 Brawn D Grey Color Coding U1 Black 1 V1 Black 2 W1 Black 3 U2 Black 4 V2 Black 5 W2 Black 6 PE Yellow F1 Black 7 F2 Black 8 D Black 9 Intern...

Page 7: ...al Connection on Motor s Terminal Board U1 U2 Black V1 V2 Red W1 W2 Orange 3 Star Delta Starting Y Motor Connection ΙΙΙ Δ With sensors PT100 and bime 2 Power Supply Cable 1 Control Cable Colour Coding U1 Black Power Supply V1 Brown Cable 1 W1 Grey PE Yellow Colour Coding U2 Black Power Supply V2 Brown Cable 2 W2 Grey PE Yellow 1 Pow 1 C Power Supp Symbol Number Colour Type F1 1 Black Bimetallic Co...

Page 8: ...uction EN 809 1998 A1 2009 Pumps and pump units for liquids Common safety requirements EN 60335 1 2012 A13 2017 Household and similar electrical appliances Safety Part 1 General requirements EN 60335 2 41 2003 A2 2010 Household and similar electrical appliances Safety Part 2 41 Particular requirements for pumps EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC req...

Reviews: