Parameter

Function : To set type of 
defrost.

0

3

0

19

To change 
E1 
parameter, 
press the 
set key

2 = Time based defrost,  
 

independent of evap coil 

 

probe temperature. Works 

 

with E4 time duration.  

 

Comp. Condenser, Heater 

 

will be off during this type 

 

of defrost.

1 = Hot gas defrost where  
 

compressor on, heater on.

3 = No defrosting.

Use UP/DOWN keys to set 
desired value.

0 =  Heater defrost in which  
 

case compressor off,  

 

heater on.

   Fact. 

Set 

Range

Min  Max 

Description of parameters and functions.

Sr.No. 

Parameter 

Parameter setting

 method. 

E2
Parameter

Function : To set type of 
computation for defrost 
frequency.

0

1

0

20

To change 
E2 
parameter, 
press the 
set key

0 = Total of real time. 
 

This  means  that  the  time   

 

c a l c u l a t i o n   f o r   d e f r o s t    

 

frequency will be for the total 

 

hours  the  unit  has  been   

 

running.

  

Example :

 If E3 is set to 6 hrs and 

3:40  hrs  have  passed  after  unit 
has started and power fails, then 
defrost cycle will start after 3:30 
hours when power resumes.

1= Sum  of  total  compressor   
 

operating  times.  This  means 

 

that  for  time  calculation,  the 

 

unit will add the total time the 

 

compressor  has  been  in  an 

 

ON mode. 

it keeps a records of the number 
of  hours  worked  +/-  ½  hour, 
incase of a power failure.

Use  UP/DOWN  keys  to  set 
desired value.

Ct 
Parameter

To change 
Ct 
parameter, 
press the 
set key

Function : To set Quick 
Freeze time duration.

Use UP/DOWN keys to set 
desired value.This is the 
maximum amount of time 
allowed for Quick freeze. If set 
to 0, there will be no quick 
freeze.

Example :

 

See CS parameter

0 HRS 30 HRS 0 HRS

17

CS 
Parameter

Function : To set quick freeze 
set point.

16

(P3+0.

O

1) C

(SP-

O

0.1) C

O

-5.0 C

To change 
CS 
parameter, 
press the 
set key

Use  UP/DOWN  keys  to  set 
desired value.

Example : 

If this is set to -5°C,  

and quick freeze time duration 
is set to 1 hr, then when it is 
set to quick freeze mode,  the 
compressor will take -5°C set 
point for 1 hr.

Description of parameters and functions.

Sr.No. 

Parameter 

Parameter setting

 method. 

   Fact. 

Set 

Range

Min  Max 

To change 
E0 
parameter, 
press the 
set key

Example : 

This parameter will 

help to achieve first defrost 
cycle in short amount of time 
after power on. If E3 < E0 then 
power up defrost cycle will be 
ignore as frequency defrost 
cycle achieved before power 
up defrost cycle.

2 = Power up defrost after 2 Hr.

0 = No power up defrost.

Use  UP/DOWN  keys  to  set 
desired  value.This  parameter 
will  decide  to  start  power  up 
defrost or not.

1 = Power up defrost after 1 Hr.

3 = Power up defrost after 3 Hr.

To change 
L6 
parameter, 
press the 
set key

0 = Evap. fan will stay on during 

1 = Evap. Fan will stay off during   
      defrost.

Use  UP/DOWN  key  to  set 
desired value. 

      defrost.

 

9

10

L4 
Parameter

Function : Evap. fan 
differential (hysteresis).

0

0.5 C

0

20.0 C

0

2.0 C

13

Description of parameters and functions.

Sr.No. 

Parameter 

Parameter setting

 method. 

   Fact. 

Set 

Range

Min  Max 

L6 
Parameter

Function : Evap. fan status 
during defrost.

0

1

1

15

L5 
Parameter

Function : To set coil probe 
offset calibration (evap. fan 
coil probe).

0

C

-10.0

10.0

0

C

0

0.0 C

14

To change 
L5 
Parameter, 
press the 
set key

In time it may be possible that 
the temp. on LCD display may 
be offset by a degree or so. To 
compensate for this error, you 
may need to add or minus the 
degrees required to achieve 
the correct temperature.

Example :

 The temperature 

on the LCD is 28.0°C, 
whereas the actual 
temperature is 30.0°C. You will 
need to set this parameter to 
2.0°C, which means that once 
out of programming mode, the 
temperature will show 
30.0°C(28.0°C + 2.0°C). 

Use UP/DOWN keys to set 
desired value.

To change 
L4 
Parameter, 
press the 
set key

Use  UP/DOWN  keys  to  set 
desired value.

Example : 

If L1 parameter is 

set to 2.0°C, and the L4 is set 
to 2.0°C, then evap. fan will cut 
off at 2.0°C and restart only at 
0.0°C. 

Description of parameters and functions.

Sr.No. 

Parameter 

Parameter setting

 method. 

   Fact. 

Set 

Range

Min  Max 

1 HRS 31 HRS 6 HRS

To change 
E3 
parameter, 
press the 
set key

E3 
Parameter

Function : To set defrost 
frequency.

21

Use  UP/DOWN  keys  to  set 
desired value.

This  is  the  amount  of  time 
between two defrost cycles.

Example:  If  this  parameter  is 
set to 1, then when comp. OFF, 
evap. fan will remain ON.

E0 
Parameter

Function : To set  activate 
power up defrost cycle.

0

3

0

18

Summary of Contents for sub-zero SZ-7534

Page 1: ...ate power up defrost cycle Quick Freeze time duration 10 11 E2 Type of computation for defrost frequency E3 Defrost frequency E4 Maximum Defrost duration E5 Defrost stop temperature Evap Coil probe 12...

Page 2: ...SOR 1 5 METER Key Introduction Quick Freeze This key used to put controller in quick freeze mode To activate this mode press QF key for 4 seconds The compressor operates in this mode for time duration...

Page 3: ...to set desired value To change do parameter press the set key L1 Parameter Function Evap Fan stop coil temp 0 C 50 0 50 0 0 C 0 2 0 C 10 5 6 Fact Set Range Max 10 0 C 0 0 C 30 Min 3 Min Description o...

Page 4: ...r press the set key Example This parameter will help to achieve first defrost cycle in short amount of time after power on If E3 E0 then power up defrost cycle will be ignore as frequency defrost cycl...

Page 5: ...Max 14 Description of parameters and functions Sr No Parameter Parameter setting method Fact Set Range Min Max E6 Parameter To change E6 parameter press the set key 24 Function To set Alarm on heater...

Page 6: ...of IP64 rated Display 3X14 2mm 0 56 LED Compressor Relay 20A 12VDC res Fan Relay 10A 12VDC res Light Relay 10A 12VDC res 0 Resolution 0 1 C 19 Suggested Connection Diagram 20 SZ 7534 prg SET RST 2 2 3...

Page 7: ...by any means without the prior written permission of the company PVR CONTROLS reserves the right to make and changes or improvements without prior notice 22 21 CAUTION Maintenance Cleaning Clean the...

Reviews: